Determination of Tone Level<br />

The sound pressure level of the tone L pt, is determined<br />

by energy summing all spectral lines classified as ‘tone’<br />

spl<br />

sum<br />

� 10 * log<br />

If there are more than 2 lines then a correction must be<br />

applied for using the Hanning window. Divide the<br />

energy sum by 1.5.<br />

L pt = 51.88 dB A<br />

n<br />

10 �<br />

i�1<br />

NATIONAL RENEWABLE ENERGY LABORATORY<br />

10<br />

0.<br />

1*<br />

spl<br />

i<br />

Freq (Hz) spl (dB A) Classification 10^0.1*spl<br />

198 25.30 0.0<br />

201 25.50 0.0<br />

204 26.02 0.0<br />

207 29.15 0.0<br />

210 32.15 0.0<br />

213 37.62 tone 5781.6<br />

216 39.88 tone 9733.2<br />

219 39.75 tone 9447.3<br />

222 39.86 tone 9678.8<br />

225 41.20 tone 13176.0<br />

228 40.31 tone 10750.3<br />

231 42.48 tone 17696.5<br />

234 43.87 tone 24360.8<br />

237 42.31 tone 17038.8<br />

240 43.43 tone 22031.6<br />

243 43.21 tone 20962.0<br />

246 43.50 tone 22364.2<br />

249 45.44 tone 34958.8<br />

252 41.22 tone 13247.8<br />

255 35.09 0.0<br />

258 30.45 0.0<br />

261 29.38 0.0<br />

264 30.78 0.0<br />

267 27.78 0.0<br />

270 26.37 0.0<br />

273 26.79 0.0<br />

276 27.61 0.0<br />

279 28.68 0.0<br />

282 27.74 0.0<br />

285 27.67 0.0<br />

288 27.38 0.0<br />

291 27.10 0.0<br />

294 27.68 0.0<br />

297 27.91 0.0<br />

300 27.46 0.0<br />

sum/1.5 154151.80<br />

Lpt 51.88