03.03.2013 Views

TechniPlan Intelligence By Dornbracht RainSky E - AGS, The ...

TechniPlan Intelligence By Dornbracht RainSky E - AGS, The ...

TechniPlan Intelligence By Dornbracht RainSky E - AGS, The ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>RainSky</strong> E <strong>Intelligence</strong> by <strong>Dornbracht</strong><br />

TECHNICAL DATA<br />

PLUMBING<br />

RAIN SKY E FLOW RATE AT 3 BAR FLOW PRESSURE<br />

Head spray 18 l/min<br />

Body spray 18 l/min<br />

Rain curtain 18 l/min<br />

Total 35 l/min<br />

Hand shower 11 l/min<br />

Mist 1 l/min<br />

WATER CONSUMPTION PER SCENARIO<br />

RESTART Total: approx. 80 litres at 38 ° C<br />

RELOAD Total: approx. 50 litres at 38 ° C<br />

RETURN Total: approx. 110 litres at 38 ° C<br />

FLOW PRESSURE<br />

Minimum flow pressure 2.5 bar<br />

Maximum flow pressure 4.0 bar<br />

Maximum difference in flow pressure 1.0 bar<br />

between hot and cold water<br />

TEMPERATURE<br />

Maximum hot water temperature +60 ° C<br />

Minimum hot water temperature +50 ° C<br />

Recommended cold water temperature range +10 ° to +20 ° C<br />

WEIGHT<br />

Ceiling module 60 kg<br />

ELECTRICAL<br />

Electricity supply 230 V, 50 – 60 Hz, 200 Watt<br />

Power consumption in stand-by mode 22 Watt<br />

Control cable for ceiling module control panel 5 m in scope of supply<br />

(hardwired in ceiling module)<br />

Control cable for fragrance module 3 m in scope of supply<br />

control panel (hardwired in fragrance module)<br />

System of protection IP 55<br />

Safety marks TÜV (type approval), GS, CE<br />

<strong>TechniPlan</strong> Technical data 25