Temperature in grain stores and silos

Temperature in grain stores and silos

Temperature in grain stores and silos

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Measurement & follow-up<br />

Just one click on the measure icon will<br />

start the manual temperature measurement<br />

of all cables. You can directly<br />

see the measurement progress as<br />

the cable currently queried will be<br />

marked blue. DuoL<strong>in</strong>e soft evaluates<br />

immediately the temperatures <strong>and</strong><br />

changes the cable colours <strong>in</strong> case of<br />

alarm. When the measurement process<br />

is f<strong>in</strong>ished the user confirms a<br />

possible alarm background <strong>in</strong>dication<br />

<strong>and</strong> played sound by click<strong>in</strong>g on the<br />

“switch off alarm” icon. Then he can<br />

follow-up critical cables step by step:<br />

A right-side-click <strong>in</strong>dicates the table of<br />

current sensor temperatures, a left-sideclick<br />

activates a temperature diagram,<br />

show<strong>in</strong>g the temperature development<br />

of the different sensors over the time<br />

(range of both axis can be changed). If<br />

desired you can zoom <strong>in</strong> marked areas<br />

<strong>and</strong> put a po<strong>in</strong>ter to the <strong>in</strong>terest<strong>in</strong>g<br />

curve to see the measured value <strong>and</strong><br />

time <strong>in</strong> exact figures. By this DuoL<strong>in</strong>e<br />

soft supplies all necessary <strong>in</strong>formation<br />

soon, well arranged <strong>and</strong> efficient to the<br />

user. Alternatively it is also possible to<br />

measure only one s<strong>in</strong>gle cell e.g. for<br />

controll<strong>in</strong>g ventilation, cool<strong>in</strong>g or gass<strong>in</strong>g<br />

progress.<br />

Fully automatic operation<br />

DuoL<strong>in</strong>e soft is designed for a fully<br />

automatic operation. The operator can<br />

def<strong>in</strong>e measurement <strong>in</strong>tervals or measurement<br />

times. At the preset times the<br />

software starts the measurement <strong>and</strong><br />

gives alarm if the preset alarm criteria<br />

are fulfilled.<br />

When the software runs <strong>in</strong> background,<br />

the DuoL<strong>in</strong>e STAR soft icon <strong>in</strong> the task<br />

bar starts flash<strong>in</strong>g <strong>in</strong> case of alarm.<br />

Pr<strong>in</strong>t<strong>in</strong>g<br />

DuoL<strong>in</strong>e soft allows to pr<strong>in</strong>t a protocol<br />

with the temperature read<strong>in</strong>gs <strong>in</strong>clud<strong>in</strong>g<br />

their difference aga<strong>in</strong>st the former<br />

measurement: All values can be reduced<br />

to critical read<strong>in</strong>gs or limit read<strong>in</strong>gs<br />

only by us<strong>in</strong>g the filter function. The<br />

<strong>in</strong>tegrated pr<strong>in</strong>t preview shows you the<br />

result<strong>in</strong>g report on the PC screen before<br />

pr<strong>in</strong>t<strong>in</strong>g. The protocol conta<strong>in</strong>s also the<br />

def<strong>in</strong>ed limit criteria, measur<strong>in</strong>g<br />

time, user address.<br />

Alarm values are pr<strong>in</strong>ted<br />

<strong>in</strong> bold characters.<br />

Pfeuffer GmbH<br />

Flugplatzstraße 70<br />

D-97318 Kitz<strong>in</strong>gen<br />

Phone +49-9321-93 69-0<br />

Fax +49-9321-93 69-50<br />

e-mail <strong>in</strong>fo@pfeuffer.com<br />

Historical temperature values stored<br />

<strong>in</strong> the data base are available for pr<strong>in</strong>t<br />

protocol as well. Pr<strong>in</strong>t<strong>in</strong>g the ground<br />

plan <strong>and</strong> temperature diagrams is also<br />

possible.<br />

We reserve the right to make technical modifications !<br />

<strong>Temperature</strong> <strong>in</strong> gra<strong>in</strong> <strong>stores</strong> <strong>and</strong> <strong>silos</strong><br />

Dust-Ex-Approval accord<strong>in</strong>g to ATEX 100a*<br />

Simple <strong>and</strong> <strong>in</strong>tuitive operation<br />

Graphical <strong>Temperature</strong> curves<br />

Easy <strong>in</strong>stallation through bus<br />

Fully automatic control<br />

Integrated data base<br />

Quickly get silo temperatures<br />

under control with the reliable,<br />

efficient <strong>and</strong> comfortable PC<br />

temperature monitor<strong>in</strong>g system.<br />

* approved <strong>in</strong> Europe under<br />

no. BVS 03 ATEX E 304<br />

for category II 1/2 D<br />

IP6X T 80°C<br />

Pfeuffer GmbH<br />

P.O. Box 248<br />

D-97305 Kitz<strong>in</strong>gen<br />

Phone +49-9321-93 69-0<br />

Fax +49-9321-93 69-50<br />

Internet www.pfeuffer.com


<strong>Temperature</strong> Monitor<strong>in</strong>g System<br />

Application<br />

The temperature control <strong>in</strong>side the<br />

gra<strong>in</strong> store is one of the most important<br />

measures to guarantee storage<br />

quality. Increas<strong>in</strong>g temperatures are an<br />

<strong>in</strong>dicator for pest <strong>in</strong>festation or moisture<br />

problems. The temperature monitor<strong>in</strong>g<br />

system DuoL<strong>in</strong>e STAR is used for<br />

fully automatic temperature control <strong>in</strong><br />

gra<strong>in</strong> <strong>stores</strong> to recognise <strong>and</strong> prevent<br />

damages <strong>in</strong> time. DuoL<strong>in</strong>e STAR can<br />

also be used to control the efficiency of<br />

measures taken for the health preservation,<br />

just as cool<strong>in</strong>g, ventilation <strong>and</strong><br />

gass<strong>in</strong>g.<br />

DuoL<strong>in</strong>e STAR System<br />

The sensors are digitally connected<br />

to the PC operated DuoL<strong>in</strong>e soft box by<br />

means of control modules via a fourwire-bus<br />

. In addition to this an external<br />

temperature, humidity <strong>and</strong> dew po<strong>in</strong>t<br />

sensor (option) can be connected to<br />

the bus. The <strong>in</strong>stallation efforts are<br />

very small for exist<strong>in</strong>g <strong>in</strong> the same way<br />

as for new build<strong>in</strong>gs! The silo plan is<br />

graphically presented on the PC screen<br />

show<strong>in</strong>g directly the locations of temperature<br />

problems.<br />

The user friendly software<br />

DuoL<strong>in</strong>e soft provides the<br />

complete solution on your PC:<br />

Operation of the system,<br />

fully automatic temperature<br />

measurement <strong>and</strong> comfortable<br />

evaluation.<br />

Sensors<br />

Flat <strong>stores</strong> <strong>and</strong> small silo b<strong>in</strong>s up to a<br />

bulk height of max. 12 m:<br />

Glass fibre probes‚ directly <strong>in</strong>serted<br />

after the storage b<strong>in</strong> has been filled<br />

Silos <strong>and</strong> high <strong>stores</strong> up to 70 m:<br />

High load sensor cables for the safe<br />

silo operation with suspension head<br />

to be mounted to beams, catwalks<br />

<strong>and</strong> roof braces; approved for dust<br />

explosion zones 20 <strong>and</strong> 21<br />

High load sensor cables DLS with base<br />

socket to be mounted on the silo roof<br />

or cast <strong>in</strong> the concrete ceil<strong>in</strong>g. The<br />

control module is supplied with factory<br />

pre-wir<strong>in</strong>gs approved for dust explosion<br />

zone 20 <strong>and</strong> 21.<br />

Easy <strong>in</strong>stallation<br />

The DuoL<strong>in</strong>e STAR-bus allows a fast<br />

<strong>and</strong> economic cabl<strong>in</strong>g. The <strong>in</strong>stallation<br />

work is reduced to a m<strong>in</strong>imum, as only<br />

four leads are required for the complete<br />

long-distance cabl<strong>in</strong>g. DuoL<strong>in</strong>e STAR<br />

is suitable for serial <strong>and</strong> star-shaped<br />

<strong>in</strong>stallation or a comb<strong>in</strong>ation of both.<br />

The bus cable is connected to the<br />

DuoL<strong>in</strong>e soft box which h<strong>and</strong>les data<br />

transmission with the PC by USB. Duo-<br />

L<strong>in</strong>e soft runs under W<strong>in</strong>dows 2000/XP<br />

<strong>and</strong> can easily be <strong>in</strong>stalled on every<br />

usual W<strong>in</strong>dows PC.<br />

Software philosophy<br />

DuoL<strong>in</strong>e soft is lean <strong>and</strong> comfortable.<br />

No need to navigate through<br />

convoluted menus, all frequently used<br />

functions can be activated just with<br />

one mouse click on the correspond<strong>in</strong>g<br />

icon. The DuoL<strong>in</strong>e soft philosophy<br />

is to provide the temperatures graphically<br />

processed <strong>and</strong> clearly arranged.<br />

Further details can be recalled by<br />

click<strong>in</strong>g on the desired cable. So the<br />

user can immediately see on areas of<br />

problems <strong>in</strong> the gra<strong>in</strong> storage <strong>and</strong> react<br />

immediatelly.<br />

Features<br />

The software allows you to measure,<br />

evaluate <strong>and</strong> pr<strong>in</strong>t the temperature<br />

values. In addition the <strong>in</strong>tegrated data<br />

base <strong>stores</strong> all measured data automatically.<br />

Silo cell names, limits, measurement<br />

times, pr<strong>in</strong>ter text <strong>and</strong> other<br />

parameters can be set effortlessly. With<br />

the built-<strong>in</strong> CAD tool you can comfortably<br />

configure the system while draw<strong>in</strong>g<br />

the cables <strong>and</strong> cells by drag <strong>and</strong><br />

drop <strong>in</strong> the floor plan. Different operation<br />

languages are available <strong>and</strong> can be<br />

changed “on-l<strong>in</strong>e” by the user.<br />

Different alarm criteria<br />

The DuoL<strong>in</strong>e soft offers you the follow<strong>in</strong>g,<br />

freely def<strong>in</strong>able alarm criteria:<br />

Absolute Limit Value: Cables with<br />

temperatures rais<strong>in</strong>g the absolute limit<br />

value e.g. 30 °C will be marked red on<br />

the PC screen.<br />

Critical Area: (so called “hysteresis”)<br />

For e.g. 3 °C it is from 27 to 30 °C.<br />

Cables <strong>in</strong> the citical area with <strong>in</strong>creas<strong>in</strong>g<br />

values will marked p<strong>in</strong>k while cables<br />

with decreas<strong>in</strong>g temperatures will be<br />

yellow coloured.<br />

Delta Alarm: Increases a temperature<br />

e.g. by 5 °C <strong>in</strong> 7 days alarm is <strong>in</strong>dicated<br />

by a purple cable.<br />

The alarm criteria can be def<strong>in</strong>ed generally<br />

or cell specific. You can also select<br />

certa<strong>in</strong> sensors for non-consideration<br />

dur<strong>in</strong>g alarm evaluation (e.g. top sensor<br />

for partly filled steel <strong>silos</strong>).<br />

In case of alarm the background of<br />

the ground plan will get red show<strong>in</strong>g<br />

“ALARM” <strong>and</strong> the DuoL<strong>in</strong>e soft icon<br />

<strong>in</strong> the task bar stats flash<strong>in</strong>g. A user<br />

def<strong>in</strong>ed sound file can be played by the<br />

PC supplementary.