■ Technical data (continued)<br />

Technical data for versions with flat plate heatsink<br />

The flat plate heatsink version offers space saving <strong>and</strong> favorable<br />

heat dissipation because an additional heatsink can be installed<br />

outside the control cabinet.<br />

Derating data<br />

Pulse frequency<br />

The current data applies for an ambient temperature of 50 °C<br />

unless otherwise specified.<br />

SINAMICS <strong>G110</strong><br />

Chassis units<br />

Frequency inverters<br />

Humidity 95% (non-condensing)<br />

Operational altitudes up to 1000 m above sea level without derating<br />

Rated output current<br />

at 4000 m above sea level: 90%<br />

Supply voltage<br />

up to 2000 m above sea level: 100%<br />

at 4000 m above sea level: 75%<br />

Protection features for undervoltage, overvoltage, earth faults, short circuits, stall prevention, I2t thermal motor protection,<br />

inverter over-temperature, motor over-temperature<br />

Conformity with st<strong>and</strong>ards UL, cUL, CE, c-tick<br />

CE marking conformity with EC low voltage directive 73/23/EEC<br />

Dimensions <strong>and</strong> weights<br />

Frame size Dimensions Weight, approx. (kg)<br />

(without options)<br />

HxWxD<br />

(FS) mm unfiltered filtered<br />

A ≤ 0.37 kW 150 x 90 x 116 0.7 0.8<br />

A 0.55 kW <strong>and</strong> 0.75 kW 150 x 90 x 131 0.8 0.9<br />

A ≤ 0.37 kW with flat plate heatsink 150x90x101 0.6 0.7<br />

A 0.55 kW <strong>and</strong> 0.75 kW with flat plate heatsink 150 x 90 x 101 0.7 0.8<br />

B 160 x 140 x 142 1.4 1.5<br />

C 2.2 kW 181 x 184 x 152 1.9 2.1<br />

C 3.0 kW 181 x 184 x 152 2.0 2.2<br />

Output 120 W 250 W 370 W 550 W 750 W<br />

Operating temperature -10 °C to +50 °C -10 °C to +50 °C -10 °C to +50 °C -10 °C to +50 °C -10 °C to +40 °C<br />

Total losses at full load <strong>and</strong> maximum<br />

operating temperature as specified<br />

22 W 28 W 36 W 43 W 54 W<br />

Line-side <strong>and</strong> control losses 9W 10 W 12 W 13 W 15 W<br />

Recommended thermal resistance of<br />

heatsink<br />

3.0 K/W 2.2 K/W 1.6 K/W 1.2 K/W 1.2 K/W<br />

Recommended output current 0.9 A 1.7 A 2.3 A 3.2 A 3.9 A<br />

Output Rated output current in A<br />

for a pulse frequency of<br />

kW 2kHz 4kHz 6kHz 8kHz 10 kHz 12 kHz 14 kHz 16 kHz<br />

0.12 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9<br />

0.25 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7<br />

0.37 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3<br />

0.55 3.2 3.2 3.2 3.2 3.0 2.7 2.5 2.2<br />

0.75 (at 40 °C) 3.9 3.9 3.9 3.9 3.6 3.3 3.0 2.7<br />

0.75 3.2 3.2 3.2 3.2 3.0 2.7 2.5 2.2<br />

1.1 6.0 6.0 6.0 6.0 5.9 5.7 5.6 5.4<br />

1.5 (at 40 °C) 7.8 7.8 7.8 7.8 7.6 7.4 7.2 7.0<br />

1.5 6.0 6.0 6.0 6.0 5.9 5.7 5.6 5.4<br />

2.2 11.0 11.0 11.0 11.0 10.8 10.5 10.2 9.9<br />

3.0 (at 40 °C) 13.6 13.6 13.6 13.6 13.3 12.9 12.6 12.3<br />

3.0 11.0 11.0 11.0 11.0 10.8 10.5 10.2 9.9<br />

<strong>Siemens</strong> D 11.1 · December 2003 5