■ Technical data (continued)<br />
Technical data for versions with flat plate heatsink<br />
The flat plate heatsink version offers space saving <strong>and</strong> favorable<br />
heat dissipation because an additional heatsink can be installed<br />
outside the control cabinet.<br />
Derating data<br />
Pulse frequency<br />
The current data applies for an ambient temperature of 50 °C<br />
unless otherwise specified.<br />
SINAMICS <strong>G110</strong><br />
Chassis units<br />
Frequency inverters<br />
Humidity 95% (non-condensing)<br />
Operational altitudes up to 1000 m above sea level without derating<br />
Rated output current<br />
at 4000 m above sea level: 90%<br />
Supply voltage<br />
up to 2000 m above sea level: 100%<br />
at 4000 m above sea level: 75%<br />
Protection features for undervoltage, overvoltage, earth faults, short circuits, stall prevention, I2t thermal motor protection,<br />
inverter over-temperature, motor over-temperature<br />
Conformity with st<strong>and</strong>ards UL, cUL, CE, c-tick<br />
CE marking conformity with EC low voltage directive 73/23/EEC<br />
Dimensions <strong>and</strong> weights<br />
Frame size Dimensions Weight, approx. (kg)<br />
(without options)<br />
HxWxD<br />
(FS) mm unfiltered filtered<br />
A ≤ 0.37 kW 150 x 90 x 116 0.7 0.8<br />
A 0.55 kW <strong>and</strong> 0.75 kW 150 x 90 x 131 0.8 0.9<br />
A ≤ 0.37 kW with flat plate heatsink 150x90x101 0.6 0.7<br />
A 0.55 kW <strong>and</strong> 0.75 kW with flat plate heatsink 150 x 90 x 101 0.7 0.8<br />
B 160 x 140 x 142 1.4 1.5<br />
C 2.2 kW 181 x 184 x 152 1.9 2.1<br />
C 3.0 kW 181 x 184 x 152 2.0 2.2<br />
Output 120 W 250 W 370 W 550 W 750 W<br />
Operating temperature -10 °C to +50 °C -10 °C to +50 °C -10 °C to +50 °C -10 °C to +50 °C -10 °C to +40 °C<br />
Total losses at full load <strong>and</strong> maximum<br />
operating temperature as specified<br />
22 W 28 W 36 W 43 W 54 W<br />
Line-side <strong>and</strong> control losses 9W 10 W 12 W 13 W 15 W<br />
Recommended thermal resistance of<br />
heatsink<br />
3.0 K/W 2.2 K/W 1.6 K/W 1.2 K/W 1.2 K/W<br />
Recommended output current 0.9 A 1.7 A 2.3 A 3.2 A 3.9 A<br />
Output Rated output current in A<br />
for a pulse frequency of<br />
kW 2kHz 4kHz 6kHz 8kHz 10 kHz 12 kHz 14 kHz 16 kHz<br />
0.12 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9<br />
0.25 1.7 1.7 1.7 1.7 1.7 1.7 1.7 1.7<br />
0.37 2.3 2.3 2.3 2.3 2.3 2.3 2.3 2.3<br />
0.55 3.2 3.2 3.2 3.2 3.0 2.7 2.5 2.2<br />
0.75 (at 40 °C) 3.9 3.9 3.9 3.9 3.6 3.3 3.0 2.7<br />
0.75 3.2 3.2 3.2 3.2 3.0 2.7 2.5 2.2<br />
1.1 6.0 6.0 6.0 6.0 5.9 5.7 5.6 5.4<br />
1.5 (at 40 °C) 7.8 7.8 7.8 7.8 7.6 7.4 7.2 7.0<br />
1.5 6.0 6.0 6.0 6.0 5.9 5.7 5.6 5.4<br />
2.2 11.0 11.0 11.0 11.0 10.8 10.5 10.2 9.9<br />
3.0 (at 40 °C) 13.6 13.6 13.6 13.6 13.3 12.9 12.6 12.3<br />
3.0 11.0 11.0 11.0 11.0 10.8 10.5 10.2 9.9<br />
<strong>Siemens</strong> D 11.1 · December 2003 5