<strong>Third</strong> <strong>Party</strong> <strong>Instrument</strong> <strong>Integration</strong><br />

The following third party instruments can be connected to FORUM ® Archive & Viewer<br />

<strong>Instrument</strong> Type Software Version DICOM*<br />

FORUM<br />

Link Port<br />

Auto Refractor<br />

Topcon TRK-1P IM<strong>AG</strong>Enet*** X<br />

Topcon CV-5000 KB-50, CV-5000 lite / KB-10, CV-5000 PC IM<strong>AG</strong>Enet*** X<br />

Topcon RM-KR 8900<br />

Fundus Camera<br />

IM<strong>AG</strong>Enet*** X<br />

Canon CF-1, CR-1 Mark II,CR-2, CX-1 Retinal Imaging Control Software (RICS) X<br />

Escalon E5 Series, E6 Duel, E6 Single, E11 Ophthavision Imaging and Angiography SW X**<br />

Heidelberg HRC Color (FA) HEYEX X** X<br />

Kowa Handheld Genesis D / Df / VK-2 VK-2 (USB) VKDICOM X** X<br />

Kowa nonmyd alpha-D III / VK-2 VK-2 Digital Imaging System X<br />

Kowa nonmyd 7 / VK-2 VK-2 Digital Imaging System X<br />

Kowa V-10 alpha / VK-2 VK-2 Digital Imaging System X<br />

Nidek AFC-210, AFC-230 NAVIS (Lite) (USB 2.0) X<br />

Nidek Orion X<br />

Topcon TRC-50DX / DXI IM<strong>AG</strong>Enet R-4 / 2000 X<br />

Topcon TRC-NW 7SF Mark II IM<strong>AG</strong>Enet R-4 / 2000 X<br />

Topcon TRC-NW 300 IM<strong>AG</strong>Enet R-4 or IM<strong>AG</strong>Enet Lite X<br />

Topcon TRC-NW6S / NW8 / NW8F<br />

Optical Tomography<br />

IM<strong>AG</strong>Enet Lite X<br />

Haag Streit HRT Cornea, HRT Glaucoma, HRT Retina HEYEX X** X<br />

Heidelberg Spectralis OCT HEYEX X** X<br />

Heidelberg SL-OCT SL-OCT PC System X** X<br />

Heidelberg Spectralis HRA HEYEX X** X<br />

Heidelberg Spectralis HRA + OCT HEYEX X** X<br />

Nidek OCT Retina Scan RS-3000 X<br />

OPKO OCT SLO X<br />

Optovue iVue OCT, RTVue 3D OCT X<br />

Topcon 3D OCT-2000 / 3D OCT-1000<br />

Image Management Software<br />

X**<br />

Escalon OphthaVision, OphthaVision Axis X**<br />

Haag Streit EyeCap Lite / DIGITAL / DIGITAL PRO / FA DICOM SCU (needed to enable DICOM) X**<br />

OIS EyeScan WinStation-SW X**<br />

OIS Symphony X**<br />

OIS WinStation - SW X**<br />

Topcon Eyeroute / Synergy Eyeroute 7.1 / Synergy X**<br />

Oculas Image Cam 2 Imagecam2 Software X<br />

FORUM<br />

Link<br />

Net


<strong>Carl</strong> <strong>Zeiss</strong> <strong>Meditec</strong>, Inc.<br />

5160 Hacienda Drive<br />

Dublin, CA 94568<br />

USA<br />

<strong>Instrument</strong> Type Software Version DICOM* FORUM<br />

Link Port<br />

Slit Lamp<br />

Heidelberg SL-OCT SL-OCT PC System X** X<br />

Kowa DSLIS VK-2 Digital Imaging System X**<br />

Nidek AFC-210, AFC-230 X<br />

Topcon SL- D2 IM<strong>AG</strong>Enet X<br />

Topcon SL SCAN-1 IM<strong>AG</strong>Enet X<br />

Topcon TRK-1P<br />

Perimetry<br />

IM<strong>AG</strong>Enet X<br />

Medmont M700 M700, Peridata X<br />

Kowa AP-5000C VK-2 Digital Imaging System X**<br />

Heidelberg HEP HEYEX X<br />

Oculas Centerfield 2 USB port; CLIP-Strategie-Software (optional) X<br />

Oculas Easyfield X<br />

Oculas Twinfield 2<br />

Biometry / Ultrasound<br />

Twinfield 2 - Software Clip-Strategie (optional) X<br />

Ellex I3 X<br />

Haag Streit Compact Touch<br />

Haag Streit Lenstar<br />

Glaucoma management and refractive surgery X<br />

OIS OTI-SCAN 3000 IOL Software X**<br />

Quantel Aviso A/B Scan PC software driven by Aviso interface X** X<br />

Quantel Cinescan S Visuscan SW X<br />

Quantel Axis II PR<br />

Topography<br />

Echo Data Manager SW X** X<br />

B&L Orbscan X<br />

Medmont E300 X<br />

Nidek OPD-Scan II Final FitTM Software X<br />

Nidek OPD-Scan III Final FitTM Software X<br />

Nidek Magellen Corneal Mapper MM1 X<br />

Oculas PENTACAM BASIC ENTACAM CLASSIC ENTACAM HR Software BASIC CLASSIC and HR Refractiv or Cataract are optional modules X** X<br />

Oculas EASYGRAPH Easygraph (USB) OxiMap - Software X<br />

Oculas KERATOGRAPH Keratograph (USB) OxiMap - Software Imaging-SW Pupillometrie-SW TF-Scan-SW X<br />

Technolas Perfect Vision Orbscan Iiz X<br />

Tomey TMS-4 X<br />

Topcon CA-200 X<br />

Topcon KR-1W, KR-8100 (A)<br />

Tonometer<br />

IM<strong>AG</strong>Enet i-base X<br />

Nidek TONOPACHY NT - 530P (Nidek) X<br />

Tomey FT - 1000 X<br />

Topcon CT-80, CT-80A<br />

Pachymeter<br />

IM<strong>AG</strong>Enet i-base X<br />

Oculas PACHYCAM<br />

Lensometer<br />

Pachycam (USB) X<br />

Topcon CL-200 SERIES, CL-2800 IM<strong>AG</strong>Enet i-base X<br />

*Must purchase Bi-Directional Interface for 3rd party instruments off FORUM price list<br />

**May require additional software or licenses from the instrument manufacturer<br />

***Outside U.S. only<br />

Toll Free: +1 800 342 9821<br />

Phone: +1 925 557 4100<br />

Fax: +1 925 557 4101<br />

info@meditec.zeiss.com<br />

www.meditec.zeiss.com/forum<br />

<strong>Carl</strong> <strong>Zeiss</strong> <strong>Meditec</strong> <strong>AG</strong><br />

Goeschwitzer Str. 51-52<br />

07745 Jena<br />

Germany<br />

Phone: +49 36 41 220 333<br />

Fax: +49 36 41 220 282<br />

info@meditec.zeiss.com<br />

www.meditec.zeiss.com/forum<br />

FORUM<br />

Link Net<br />

FOR.3718<br />

© 2011 <strong>Carl</strong> <strong>Zeiss</strong> <strong>Meditec</strong>, Inc. All Rights Reserved. Specifications subject to change. FORUM is a registered trademark of<br />

<strong>Carl</strong> <strong>Zeiss</strong> <strong>Meditec</strong>, Inc. in the United States and/or other countries. All other trademarks are the property of their respective owners. 0611