Belden Coaxial Cables - Sacramento Mountains Radio Club
Belden Coaxial Cables - Sacramento Mountains Radio Club
Belden Coaxial Cables - Sacramento Mountains Radio Club
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
C O A X I A L C A B L E S 6.7<br />
RG <strong>Coaxial</strong> and Triaxial Reference Guide<br />
RG-6, RG-8 and RG-11 Types<br />
Cable Designation<br />
Part<br />
No.<br />
Page<br />
No.<br />
Spec.<br />
Reference<br />
Conductor<br />
Stranding/<br />
Dia. & Type*<br />
(DCR/1000 Ft.)<br />
Insulation<br />
Material<br />
(OD in.)<br />
Shield Type<br />
Tape/Braid<br />
(DCR/1000 Ft.)<br />
Jacket<br />
Material<br />
(OD in.)<br />
Nom.<br />
Weight<br />
(Lbs./Ft.)<br />
Nom.<br />
Cap.<br />
(pF/Ft.)<br />
For more information, contact <strong>Belden</strong> Technical Support: 1-800-BELDEN-1 • www.belden.com<br />
Nom.<br />
Imp.<br />
(Ω)<br />
Suggested<br />
Operating<br />
Temp. Range<br />
(°C) UL<br />
RG-6 Type (continued)<br />
RG-6/U Type 82120 6.25 <strong>Belden</strong> 1/.040″ BCCS FFEP DF/95% TC FLM .044 75 16.5 -20 to +75 300<br />
Plenum (28.0) (.170) (1.7) (.234)<br />
RG-6/U Type 82248 6.38 <strong>Belden</strong> 1/.040″ BC FFEP DF/65% TC FLM .035 75 16.5 -20 to +75 300<br />
Plenum (6.4) (.170) (5.1) (.222)<br />
RG-6/U Type 87120 6.25 <strong>Belden</strong> 1/.040″ BCCS FFEP DF/95% TC PVDF .043 75 16.5 -20 to +150 300<br />
Plenum (28.0) (.170) (1.7) (.234)<br />
RG-6/U Type 89120 6.25 <strong>Belden</strong> 1/.040″ BCCS FFEP DF/95% TC FEP .044 75 16.5 -70 to +200 300<br />
Plenum (28.0) (.170) (1.7) (.234)<br />
RG-6/U Type 89248 6.38 <strong>Belden</strong> 1/.040″ BC FFEP DF/65% TC FEP .035 75 16.5 -70 to +200 300<br />
Plenum<br />
RG-8 Type<br />
(6.4) (.170) (5.1) (.222)<br />
Max. Oper.<br />
Voltage<br />
(RMS)<br />
Non UL<br />
RG-8/U Type 7733A 6.70 <strong>Belden</strong> 1/.108″ BC FFEP DF/90% TC PVDF .115 50 24.2 -20 to +150 300<br />
(0.9) (.280) (1.8) (.355)<br />
RG-8/X Type 7808A 6.61 <strong>Belden</strong> 1/.057″ BC GIFHDPE DB/95% TC PE .036 50 23.0 -40 to +75 300<br />
RF240 (3.2) (.150) (2.8) (.240)<br />
RG-8/X Type 7808R 6.61 <strong>Belden</strong> 1/.057″ BC GIFHDPE DB/95% TC PVC .040 50 23.0 -40 to +75 300<br />
RF240 Riser (3.2) (.150) (2.8) (.240)<br />
RG-8/X Type 7808WB 6.61 <strong>Belden</strong> 1/.057″ BC GIFHDPE DB/95% TC PE .036 50 23.0 -40 to +75 300<br />
RF240 Burial (3.2) (.150) (2.8) (.240)<br />
RG-8/U Type 7810A 6.63 <strong>Belden</strong> 1/.108″ BCCA GIFHDPE DB/95% TC PE .077 50 23.0 -40 to +75 300<br />
RF400 (1.34) (.285) (2.0) (.403)<br />
RG-8/U Type 7810R 6.63 <strong>Belden</strong> 1/.108″ BCCA GIFHDPE DB/95% TC PVC .087 50 23.0 -40 to +75 300<br />
RF400 Riser (1.34) (.285) (2.0) (.403)<br />
RG-8/U Type 7810WB 6.63 <strong>Belden</strong> 1/.108″ BCCA GIFHDPE DB/95% TC PE .077 50 23.0 -40 to +75 300<br />
RF400 Burial (1.34) (.285) (2.0) (.403)<br />
RG-8/U Type 8214 6.69 <strong>Belden</strong> 7/.108″ BC FPE None/97% BC PVC .106 50 26.0 -40 to +80 300<br />
(1.2) (.285) (1.1) (.403)<br />
RG-8/U Type 8237 6.69 JAN-C-17A 7/.085″ BC PE None/97% BC PVC .104 52 28.5 -40 to +75 3,700<br />
(1.9) (.285) (1.2) (.405)<br />
RG-8/U Type 9251 6.69 MIL-C-17D 7/.085″ BC PE None/97% BC PVC-NC .099 52 28.5 -40 to +80 3,700<br />
(1.9) (.285) (1.2) (.405)<br />
RG-8/X Type 9258 6.69 <strong>Belden</strong> 19/.058″ BC GIFPE None/95% BC PVC .035 50 24.8 -30 to +80 300<br />
(4.3) (.155) (3.3) (.242)<br />
RG-8/U Type 9880 6.83 <strong>Belden</strong>, DEC 1/.086″ BC FPE DBIV/94% TC PVC .113 50 26.0 -30 to +60 300<br />
Thick Ethernet PN17-00451-00 (1.4) (.243) 90% TC<br />
(1.5)<br />
(.405)<br />
RG-8/U Type 9888 6.90 <strong>Belden</strong> 7/.108″ BC FPE Inner Inner PE .130 50 26.0 -55 to +80 300<br />
Triaxial (1.2) (.285) None/96% BC (.370)<br />
(1.2) Outer PE<br />
Outer<br />
None/96% BC<br />
(2.1)<br />
(.480)<br />
RG-8/U Type 9913 6.70 <strong>Belden</strong> 1/.108″ BC SSPE DBII/90% TC PVC .097 50 24.6 -40 to +80 300<br />
(0.9) (.286) (1.8) (.405)<br />
RG-8/U Type 9913F7 6.70 <strong>Belden</strong> 7/.108″ BC GIFHDPE DB/95% TC BELFX .094 52 22.5 -40 to +80 300<br />
(1.1) (.285) (1.8) (.405)<br />
RG-8/U Type 9914 6.70 <strong>Belden</strong> 1/.103″ BC GIFHDPE DBII/95% TC PVC .108 50 24.8 -40 to +80 300<br />
(1.8) (.285) (1.1) (.403)<br />
RG-8/U Type 89880 6.83 <strong>Belden</strong>, DEC 1/.086″ BC FFEP DBIV/90% TC PVDF .137 50 26.0 -25 to +150 300<br />
Thick Ethernet PN17-00324-00 (1.4) (.245) 90% TC (.375)<br />
Plenum (1.5)<br />
RG-8/U Type 89913 6.70 <strong>Belden</strong> 1/.108″ BC SSFEP DBII/90% TC PVDF .115 50 25.0 -20 to +150 300<br />
Plenum<br />
RG-11 Type<br />
(0.9) (.295) (1.8) (.364)<br />
RG-11/U Type 1153A 6.28 <strong>Belden</strong>, IBM 1/.064″ BCCS FFEP DF/60% TC FEP .092 75 16.2 -70 to +200 300<br />
Plenum P/N1501908 (11.0) (.280) DF/40% TC<br />
(1.8)<br />
(.387)<br />
RG-11/U Type 1523A 6.26 <strong>Belden</strong> 1/.064″ BCCS GIFPE DBII/60% AL PVC .054 75 16.2 -40 to +80 300<br />
(11.0) (.280) (4.1) (.400)<br />
RG-11/U Type 1523AN 6.26 <strong>Belden</strong> 1/.064″ BCCS GIFPE DBII/60% AL PVC .054 75 16.2 -40 to +80 300<br />
(11.0) (.280) (4.1) (.400)<br />
RG-11/U Type 1523AP 6.26 <strong>Belden</strong> 1/.064″ BCCS FFEP DBII/60% AL PVDF .057 75 16.3 -20 to +150 300<br />
Plenum (11.0) (.274) (4.1) (.348)<br />
*Inner conductors are entered as: number of strands/strand diameter (in inches). See page 6.15 for key to abbreviations used in this table.<br />
6 • <strong>Coaxial</strong> <strong>Cables</strong>