C O A X I A L C A B L E S 6.9<br />

RG <strong>Coaxial</strong> and Triaxial Reference Guide<br />

RG/11U and RG-58 Types<br />

Cable Designation<br />

Part<br />

No.<br />

Page<br />

No.<br />

Spec.<br />

Reference<br />

Conductor<br />

Stranding/<br />

Dia. & Type*<br />

(DCR/1000 Ft.)<br />

Insulation<br />

Material<br />

(OD in.)<br />

Shield Type<br />

Tape/Braid<br />

(DCR/1000 Ft.)<br />

Jacket<br />

Material<br />

(OD in.)<br />

Nom.<br />

Weight<br />

(Lbs./Ft.)<br />

Nom.<br />

Cap.<br />

(pF/Ft.)<br />

For more information, contact <strong>Belden</strong> Technical Support: 1-800-BELDEN-1 • www.belden.com<br />

Nom.<br />

Imp.<br />

(Ω)<br />

Suggested<br />

Operating<br />

Temp. Range<br />

(°C) UL<br />

Max. Oper.<br />

Voltage<br />

(RMS)<br />

Non UL<br />

RG-11/ U Type (continued)<br />

RG-11/U Type 9011 6.26 <strong>Belden</strong> 1/.064″ BCCS GIFPE DF/40% AL PVC .060 75 16.2 -40 to +80 300<br />

(11.0) (.280) (5.3) (.400)<br />

RG-11/U Type 9064 6.27 <strong>Belden</strong> 1/.064″ BCCS GIFPE DB+/77% AL PVC .062 75 16.2 -40 to +80 300<br />

(11.0) (.280) (3.8) (.400)<br />

RG-11/U Type 9065M 6.27 <strong>Belden</strong> 1/.064″ BCCS GIFPE DB+/77% AL PVC .080 75 16.2 -40 to +80 300<br />

Messengered (11.0) (.280) (3.8) (.400 x .580)<br />

RG-11/U Type 9192 6.53 <strong>Belden</strong> 19/.064″ BC GIFHDPE Inner Inner .134 75 17.3 -40 to +75 300<br />

Triaxial (3.3) (.312) None/90% BC PE<br />

(1.6) (.390)<br />

Outer Outer<br />

None/82% BC PVC<br />

(1.6) (.520)<br />

RG-11/QPL 9212 6.79 MIL-C-17G 7/.048″ TC PE None/97% BC PVC-NC .090 75 20.5 -40 to +85 3,700<br />

M17/6-RG11 (6.1) (.285) (1.2) (.405)<br />

RG-11/U Type 9232 6.53 <strong>Belden</strong> 19/.064″ BC GIFHDPE Inner Inner PE .140 75 17.3 -20 to +75 300<br />

Triaxial (3.0) (.312) None/90% BC (.390)<br />

(1.6) Outer H<br />

Outer<br />

None/82% BC<br />

(1.7)<br />

(.520)<br />

RG-11/U Type 9292 6.39 <strong>Belden</strong> 1/.064″ BC GIFHDPE DF/61% TC PVC .081 75 16.1 -40 to +80 300<br />

(2.5) (.280) (3.0) (.405)<br />

RG-11/U Type 9764 6.27 <strong>Belden</strong> 1/.064″ BCCS GIFPE DB+/77% AL PE .056 75 16.2 -55 to +80 300<br />

Burial (11.0) (.280) (3.8) (.400)<br />

RG-11/U Type 89292 6.39 <strong>Belden</strong> 1/.064″ BC FFEP DF/63% TC FEP .077 75 16.1 -70 to +200 300<br />

Plenum<br />

RG-58 Type<br />

(2.5) (.274) (3.0) (.346)<br />

RG-58/U Type 7806A 6.60 <strong>Belden</strong> 1/.037″ BC GIFHDPE DF/90% TC PE .022 50 24.3 -40 to +75 300<br />

RF195 (7.6) (.110) (4.2) (.195)<br />

RG-58/U Type 7806R 6.60 <strong>Belden</strong> 1/.037″ BC GIFHDPE DF/90% TC PVC .026 50 24.3 -40 to +75 300<br />

RF195 Riser (7.6) (.110) (4.2) (.195)<br />

RG-58/U Type 7807A 6.60 <strong>Belden</strong> 1/.044″ BC GIFHDPE DF/95% TC PE .026 50 23.5 -40 to +75 300<br />

RF200 (3.3) (.116) (4.2) (.195)<br />

RG-58/U Type 7807R 6.60 <strong>Belden</strong> 1/.044″ BC GIFHDPE DF/95% TC PVC .029 50 23.5 -40 to +75 300<br />

RF200 Riser (3.3) (.116) (4.2) (.195)<br />

RG-58A/U Type 8219 6.68 <strong>Belden</strong> 19/.037″ TC FPE None/96% TC PVC .025 53.5 26.5 -40 to +80 300<br />

(8.8) (.114) (4.1) (.194)<br />

RG-58A/U 8240 6.68 JAN-C-17A 1/.033″ BC PE None/95% TC PVC .025 51.5 28.5 -40 to +75 1,400<br />

(10.0) (.116) (4.1) (.193)<br />

RG-58A/U Type 8259 6.68 JAN-C-17A 19/.035″ TC PE None/95% TC PVC .024 50 30.8 -40 to +75 1,400<br />

(10.8) (.116) (4.1) (.192)<br />

RG-58C/U QPL 8262 6.77 MIL-C-17G 19/.035″ TC PE None/95% TC PVC-NC .024 50 30.8 -40 to +85 1,400<br />

M17/155-00001 (10.8) (.115) (4.1) (.195)<br />

RG-58/U Type 9201 6.67 <strong>Belden</strong> 1/.033″ BC PE None/78% BC PVC .022 51.5 28.5 -40 to +80 1,400<br />

(10.0) (.116) (5.5) (.193)<br />

RG-58/QPL 9203 6.77 MIL-C-17G 19/.035″ TC PE None/95% TC PVC-NC .025 50 30.8 -40 to +85 1,400<br />

M17/28-RG-58 (10.8) (.116) (4.1) (.195)<br />

RG-58A/U Type 9222 6.90 <strong>Belden</strong> 7/.037″ TC PE Inner Inner PE .037 50 30.8 -40 to +75 1,400<br />

Triaxial (9.5) (.114) None/96% TC (.175)<br />

(4.7) Outer PVC<br />

Outer<br />

None/85% TC<br />

(4.3)<br />

(.240)<br />

RG-58/U Type 9223 6.82 <strong>Belden</strong> 7/.030″ TC PE DBII/95% TC PVC .024 50 37.0 -40 to +80 1,900<br />

(10.8) (.112) (4.1) (.195)<br />

RG-58/U Type 9310 6.67 <strong>Belden</strong> 1/.033″ BC PE DBII/55% TC PVC .020 50 30.8 -40 to +60 1,400<br />

(9.4) (.114) (8.0) (.193)<br />

RG-58A/U Type 9311 6.68 <strong>Belden</strong> 19/.037″ TC FPE DBII/55% TC PVC .018 52 26.0 -40 to +80 300<br />

(8.8) (.114) (17.0) (.193)<br />

RG-58A/U Type 9907 6.83 DEC P/N 19/.037″ TC FPE DBII/93% TC PVC .022 50 25.4 -40 to +80 300<br />

Thin Ethernets 17-01248-00 (8.8) (.102) (5.8) (.185)<br />

*Inner conductors are entered as: number of strands/strand diameter (in inches). See page 6.15 for key to abbreviations used in this table.<br />

6 • <strong>Coaxial</strong> <strong>Cables</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!