Technical Data und Instructions Country-specific design<br />

<strong>IVV</strong> <strong>1054</strong> und <strong>IME</strong> <strong>1500</strong> (on request)<br />

electric-sockets<br />

Classification conventional ballast<br />

IIb connection diameter<br />

Nominal voltage/Nominal frequency<br />

outlet points for med. gases<br />

Electrical Data sizing of pipe diameters<br />

Nominal voltage: 230 V (400V) AC operating pressure<br />

Nominal frequency: 50 Hz signal current technology/nurse call<br />

Operating mode: continuous operation<br />

Protection class: Protection class 1<br />

Type of protection: closed design Installation<br />

Heavy current connection:<br />

For the connecting of the cables (on site) there are<br />

screw less connectors for cables of up to 2.5 mm².<br />

The following connection possibilities for potential<br />

compensation with a protective connector block are at<br />

your disposal:<br />

The medical supply system, types <strong>IVV</strong> <strong>1054</strong><br />

<strong>and</strong> <strong>IME</strong> <strong>1500</strong>, must be mounted on solid<br />

walls <strong>and</strong> on light-weight partitions using<br />

appropriate fastening materials. With light-<br />

weight partitions, a suitable substructure<br />

must be provided.<br />

1 x max. 16 mm²<br />

n x max. 4 mm²<br />

Night light TC 7 Watt<br />

Nominal voltage: 230 V AC<br />

Nominal frequency: 50 HZ<br />

Connection type: Connectors with spring hold<br />

Connection diameter: single wire/fine str<strong>and</strong> 1,5 mm²<br />

Cleaning<br />

The <strong>IVV</strong> <strong>1054</strong> <strong>and</strong> <strong>IME</strong> <strong>1500</strong>-systems can be<br />

cleaned with all st<strong>and</strong>ard cleaning agents <strong>and</strong><br />

can be disinfected with all alcohol-free<br />

disinfection liquids.<br />

The surface is coated with a high quality<br />

electro static powder coating. Smooth<br />

surfaces are made of electrically-oxidized<br />

Aluminium <strong>and</strong> chrome-nickel steel. The<br />

plastic parts are cleaning <strong>and</strong> disinfection<br />

Operating pressures for med. gases<br />

liquid proof.<br />

(outlet points in accordance with<br />

DIN EN 737-1, -3, -4)<br />

Oxygen:<br />

Compressed air:<br />

Nitrous oxide:<br />

Vacuum:<br />

AGSS:<br />

5 bar<br />

5 bar<br />

5 bar<br />

- 0,8 bar<br />

5 bar<br />

Maintenance <strong>and</strong> Repair<br />

System maintenance should be carried out<br />

after 5 years <strong>and</strong> every 2 years thereafter. If<br />

desired, a customer service agreement can<br />

be drawn up at a later date.