7 Slate roofs<br />

■ Slate roofs require that the Ubiflex<br />

flashing is positioned at the top of<br />

the system.<br />

■ Position the 400mm wide Ubiflex<br />

approximately 200mm above the<br />

in-roof roll, with 20mm extending<br />

past the top batten. Unroll across<br />

the whole width of the PV field,<br />

screwing to the batten at the top<br />

edge of the roll.<br />

■ Fold the top edge back by 20mm.<br />

■ Bend both left and right hand<br />

sides back 20mm in the same<br />

manner along two thirds of<br />

the height.<br />

■ Bend the top left and right<br />

extremities in the same manner.<br />

■ Dress the bottom 200mm<br />

carefully over the in-roof roll.<br />

10 I 11 Ubbink - Solar energy systems<br />

200mm<br />

The above images are representative and may change accordingly.<br />

20mm<br />

20mm