20.03.2013 Views

PKVF 65/1B 07 - Alfons Haar Website

PKVF 65/1B 07 - Alfons Haar Website

PKVF 65/1B 07 - Alfons Haar Website

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>PKVF</strong> <strong>65</strong>/<strong>1B</strong> <strong>07</strong><br />

Pneumatic vent valve with sequence control<br />

Vent valve, pneumatically actuated for tank venting,with sequence control, according ADR 20<strong>07</strong>,<br />

with integrated pressure- vacuum valve according EN 13082 and EN 14595,<br />

leak-proof in case of overturned tank,<br />

in connection with vapour transfer valve part no. 2180904 suitable for mounting in<br />

manhole covers entirely within contour of tank shell.<br />

TÜ . AGG . 049 - 85<br />

EN 13082, EN 14595<br />

according ADR 20<strong>07</strong><br />

Part number: 2244052<br />

Dia. of opening: 3"<br />

Connection flange acc. to DIN 28 461, TW1<br />

Mounting flange: aluminium<br />

Housing: plastic<br />

Seals: viton<br />

Operating temperature range: -20° to +50°C<br />

Weight: 1.2 kg<br />

pressure drop ∆p [mbar]<br />

flow rate of air [m 3 /min] at 20°C<br />

MWP: 33 kPa<br />

Nominal relieving pressure: 8 kPa<br />

Nominal relieving vacuum: 1.25 kPa<br />

Pressure venting capacity at 30 kPa: 26 m³/h<br />

Vacuum venting capacity at 3 kPa: 144 m³/h


<strong>PKVF</strong> <strong>65</strong>/<strong>1B</strong> <strong>07</strong><br />

Pneumatic vent valve with sequence control<br />

A<br />

Diag 1: Vapour recovery system,<br />

bottom loading and discharge<br />

same side<br />

EuroSENS...<br />

• Detonation/flame arresters for mounting onto the<br />

vapour transfer valves protect the tank compartment<br />

and are approved to EN 12874<br />

• Pressure/vacuum valves integrated into the vapour<br />

transfer valves protect the tank compartments<br />

against excessive vacuum or over pressure,<br />

approved by EN 14595 and mandatory by ADR 20<strong>07</strong><br />

• Emergency pressure relief valves are not permitted,<br />

even if designed to EN 14596 *)<br />

*) As decided by joint meeting, <strong>07</strong>./11.03.2005,<br />

tank working group INF.27, No. 6<br />

<strong>PKVF</strong> <strong>65</strong>... with p/v vent<br />

and flame arrester LTD...<br />

Vapour collection<br />

manifold<br />

Vapour transfer safety valve<br />

PVREV 100 A1-E<br />

Vapour collection<br />

adaptor CAMV 100 A1<br />

View: A<br />

Vapour collection<br />

coupler<br />

ALFONS HAAR MASCHINENBAU GMBH & CO. KG • Postfach 530 160 • D-22531 Hamburg • TEL (+49) 40 833 91-0 • FAX (+49) 40 844 910<br />

INTERNET www.alfons-haar.de • E-MAIL sales@alfons-haar.de Subject to alteration

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!