18<br />
A unique and effective solution<br />
for sound insulation of tubing.<br />
Domestic and commercial buildings<br />
(hotels, hospitals, etc...) have to<br />
meet stringent requirements for<br />
acoustic features.<br />
A certified solution (by the<br />
Fraunhofer laboratory) offers the<br />
best approved result for specifiers<br />
and general contractors.<br />
Description<br />
Ready-to-use system for acoustic<br />
insulation of tubing.<br />
K-FLEX K-FONIK ST GK<br />
Fraunhofer institute certificate no. p-ba 247/2006<br />
To assess the correct level of<br />
soundproofing for waste pipes,<br />
reference should be made to Italian<br />
legislation DPCM 5/12/1997, and also<br />
tests capable of simulating the true<br />
operating conditions of the products,<br />
as per the standards set by DIN EN<br />
14366 and DIN 52219.<br />
These tests enable the evaluation of<br />
acoustic comfort in terms of LASmax<br />
and LAeq (sound pressure level)<br />
not just through R or Rw, typical<br />
parameters for sound insulation of<br />
walls, but are by no means exhaustive<br />
for tubing applications.<br />
Products not specifically tested for the<br />
above parameters are therefore not<br />
valid for use with waste pipes.<br />
Sound Pressure Level L In [dB(A)]<br />
Water capacity [I/s] 0,5 1,0 2,0 4,0<br />
Area: First floor - Area A<br />
without K-FONIK ST GK 48 52 55 57<br />
with K-FONIK ST GK 35 39 42 45<br />
Area: First floor - Area B<br />
without K-FONIK ST GK 14 18 24 27<br />
with K-FONIK ST GK 4 9 14 19<br />
The test meets the requirements of the DIN 4109 (Germany)<br />
DIN 4109/A1: 2001-01 for residential buildings and DIN 4109 for non residential buildings<br />
Applications:<br />
PART OF THE FRAUNHOFER INSTITUTE CERTIFICATE NO. P-BA 247/2006<br />
The test, shown below, is performed by simulating a real installation in a several storey<br />
building with room volumes equal to 70.4 m 3 and 52.6 m 3 (per floor).<br />
Concrete wall<br />
220 Kg/m 2<br />
B<br />
Attic<br />
V = 70,4 m 3<br />
V = 70,4 m 3<br />
Rear basement I<br />
Basement II<br />
Bend 2 x 45°<br />
A<br />
Water inflow<br />
V = 52,6 m 3<br />
Front ground floor<br />
V = 52,6 m 3<br />
Installation wall<br />
Front basement l<br />
www.kflex.com<br />
To water-collecting basin