23.03.2013 Views

GE BuyLog — Section 2: Safety Switches - GE Industrial Systems

GE BuyLog — Section 2: Safety Switches - GE Industrial Systems

GE BuyLog — Section 2: Safety Switches - GE Industrial Systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Safety</strong> <strong>Switches</strong><br />

Spec-Setter <strong>Safety</strong> <strong>Switches</strong><br />

Quick Selection Guide<br />

General Duty <strong>Safety</strong> Switch, Single-throw<br />

Max. System<br />

Voltage<br />

250Vac<br />

250Vdc<br />

Ampere<br />

Rating Switch Type Class<br />

30-<br />

200<br />

400-<br />

600<br />

Heavy Duty <strong>Safety</strong> Switch, Single-throw<br />

Max. System<br />

Voltage<br />

600Vac<br />

250Vac<br />

Double-throw <strong>Safety</strong> Switch<br />

Max. System<br />

Voltage<br />

600Vac<br />

250Vdc<br />

30-<br />

200<br />

400-<br />

600<br />

Fusible<br />

No 1<br />

Fuse<br />

Ampere<br />

Rating Switch Type Class<br />

30-<br />

1200<br />

Fusible<br />

No 1<br />

Fuse<br />

Ampere<br />

Rating Switch Type Class<br />

30-<br />

600<br />

No<br />

Fuse<br />

UL Listed Fusing<br />

Withstanding Rating<br />

(rms Sym Amps)<br />

K 10,000<br />

H 10,000<br />

R 100,000<br />

K 10,000<br />

H 10,000<br />

R 10,000<br />

K 10,000<br />

H 10,000<br />

R 100,000<br />

K 10,000<br />

H 10,000<br />

R 10,000<br />

UL Listed Fusing<br />

Withstanding Rating<br />

(rms Sym Amps)<br />

H 10,000<br />

4<br />

R 200,000<br />

4<br />

J 200,000<br />

3<br />

L 100,000<br />

H 10,000<br />

R 10,000<br />

J 10,000<br />

3<br />

L 10,000<br />

UL Listed Fusing<br />

Withstanding Rating<br />

(rms Sym Amps)<br />

10,000<br />

Enclosure<br />

Type<br />

1<br />

3R<br />

Enclosure<br />

Type<br />

1<br />

3R<br />

4/4X<br />

5,12<br />

Mill Duty<br />

Enclosure<br />

Type<br />

1Non-fusible switch withstand ratings apply when protected by corresponding listed fuse type.<br />

2100-200<br />

amp also available as Type 3R (General Duty only).<br />

3Class<br />

L fuses are only applicable when used with 800 and 1200A Type TC safety switches.<br />

4Unless otherwise noted.<br />

1 2<br />

3R<br />

<strong>BuyLog</strong><br />

Page<br />

2-5,<br />

2-6<br />

<strong>BuyLog</strong><br />

Page<br />

2-7<br />

through<br />

2-16<br />

<strong>BuyLog</strong><br />

Page<br />

2-17 through 2-19<br />

TG3321<br />

TH3361SS<br />

TC10323R<br />

2-2 <strong>BuyLog</strong> ® Catalog www.geindustrial.com<br />

Rev. 9/12<br />

<strong>Section</strong> 2<br />

Prices and data subject<br />

to change without notice