24.03.2013 Views

Verandah Conservation for Heritage Listed Places - Adelaide City ...

Verandah Conservation for Heritage Listed Places - Adelaide City ...

Verandah Conservation for Heritage Listed Places - Adelaide City ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

A d e l a i d e V e r a n d a h s<br />

V i c t o r i a n P e r i o d P R E 1 9 0 0<br />

O v e r v i e w<br />

A d e l a i d e a n d t h e o l d e r s u b u r b s h a v e t h e i r o w n d i s t i n c t i v e<br />

v e r n a c u l a r s t y l e o f n i n e t e e n t h c e n t u r y a r c h i t e c t u r e , w h i c h<br />

d i s t i n g u i s h e s i t f r o m t h e o t h e r c i t i e s . I m p o r t a n t l y t h i s v e r n a c u l a r<br />

i n c l u d e s t h e t y p i c a l A d e l a i d e v e r a n d a h a n d i t s v a r i a n t s .<br />

C o u n c i l ' s h e r i t a g e p o l i c y i s t o r e c o g n i s e + r e i n f o r c e t h i s h i s t o r i c<br />

c h a r a c t e r .<br />

STANDARD VERANDAH DETAILS<br />

Overview<br />

DRAWINGS PREPARED 30/6/07<br />

1<br />

of 5<br />

ENQUIRIES 08 8203 7445


front door transom<br />

front door threshold<br />

cast iron vent under door<br />

0.8 metal hip strap folded back on itself<br />

G L O S S A R Y O F T E R M S<br />

rolled hip flashing (acrylic coated lead)<br />

brick string course<br />

wall plate 4" x 2"<br />

chamfered<br />

roof profile -<br />

end panel -<br />

hip flashing<br />

100mm refolded OGEE gutter<br />

post / fascia housing combination<br />

scotia 32 - 42mm or 19mm square<br />

bead<br />

fascia - A B C D<br />

corner bracket -<br />

fascia return<br />

cast iron frieze (optional)<br />

capital -<br />

neck moulding-<br />

stop chamfers (chiselled ends<br />

not routed)<br />

divider screen capping<br />

divider screen -<br />

divider screen rail -<br />

post<br />

bottom rail<br />

post base -<br />

A B C D E<br />

A B C<br />

A B C D<br />

A B C D<br />

A B C D<br />

A B C<br />

A B C D<br />

verandah base edging -<br />

E<br />

A B C D<br />

A B C D<br />

R O O F P R O F I L E S<br />

EARLY<br />

VICTORIAN<br />

CONCAVE OR EYELASH<br />

A<br />

B<br />

C<br />

D<br />

E<br />

CONVEX<br />

OGEE OR BELL CURVE<br />

STRAIGHT<br />

BULLNOSE<br />

LATE<br />

VICTORIAN<br />

ADELAIDE VERANDAHS<br />

Victorian Period 1870 - 1900<br />

ADELAIDE’S OWN VERNACULAR<br />

<strong>Adelaide</strong> and its older suburbs have their own distinctive<br />

vernacular style of nineteenth century architecture, which<br />

distinguishes it from the other cities. Importantly this vernacular<br />

includes the typical <strong>Adelaide</strong> verandah and its variants.<br />

Council's heritage policy is to recognise + rein<strong>for</strong>ce <strong>Adelaide</strong>'s<br />

unique historic character, established by this vernacular based on<br />

archival photographic and physical evidence and to ensure that<br />

new and replacement verandahs are historically accurate and<br />

complement <strong>Adelaide</strong>’s historic houses.<br />

RETAINING ORIGINAL VERANDAHS AND REMNANTS<br />

Where an original verandah still exists in whole or in part, the<br />

original elements should be retained and repaired rather than<br />

replaced. It is better to have ‘The Real McCoy’ rather than a new<br />

facsimile in heritage terms. Partially rotten timber posts/fascias<br />

can often be repaired using epoxy or by splicing new timber into<br />

the remaining sound timber. Generally original galvanized iron<br />

verandah roof iron should be conserved.<br />

RESEARCH<br />

In the absence of having of an original verandah, one should<br />

endeavour to find out what the original verandah looked like.<br />

There may be remnants of the original verandah, often there is a<br />

half post remaining against the wall, sometimes complete with<br />

post mouldings. Often an impression of the original verandah half<br />

post and mouldings can be seen on the plaster quoin where a<br />

paint build impression has been left as a ghost of the original<br />

verandah. Impressions of the original roof profile are often evident<br />

where it returned to the wall.<br />

Any physical evidence found should <strong>for</strong>m the basis of the new<br />

verandah reinstatement, and any remnants should be retained<br />

and incorporated into the new verandah.<br />

Historical photos may be available from past owners or online<br />

through the State Library of South Australia Mortlock Library<br />

Pictorial Collection of South Australiana: (search the street name<br />

or town acre eg 'acre 499')<br />

www.catalog.slsa.sa.gov.au:1084/search/X<br />

Additional resources and assistance can be sought via the<br />

<strong>Adelaide</strong> <strong>City</strong> Council heritage website:<br />

www.adelaidecitycouncil.com.au/heritage<br />

STANDARD VERANDAH DETAILS<br />

page 2<br />

DRAWINGS PREPARED 30/6/07<br />

2 of 5<br />

ENQUIRIES 08 8203 7445


E N D P A N E L S<br />

acrylic coated lead rolled top<br />

flashing<br />

A<br />

HIPPED<br />

GABLE ENDED (CONCAVE)<br />

GABLE END (BULLNOSE)<br />

fit snug against<br />

the wall (no<br />

flashing)<br />

B<br />

B v a r i a n t<br />

MATERIALS<br />

- matchboard (vertical or<br />

diagonal)<br />

- mini-orb<br />

(vertical)<br />

- fine (20mm) lattice<br />

(diagonal)<br />

NOTE: A RANGE OF CAST IRON BRACKETS AND FRIEZES<br />

WERE USED IN VICTORIAN TIMES FROM THE AC HARLEY<br />

FULTONS ET AL RANGES MANY OF WHICH ARE STILL<br />

AVALIABLE. CONTACT COUNCIL HERITAGE STAFF FOR<br />

ASSISTANCE WITH APPROPRIATE SELECTIONS<br />

C O R N E R B R A C K E T S D I V I D E R S C R E E N S<br />

A<br />

B<br />

C<br />

D<br />

E<br />

A<br />

B<br />

C<br />

STRAIGHT<br />

RAKED<br />

OGEE<br />

CURVED<br />

MATERIALS<br />

- corrugated<br />

iron (19mm<br />

barrel press<br />

iron)<br />

- mini-orb<br />

- 150mm<br />

regency<br />

beaded<br />

matchboard<br />

TYPICAL DESIGN<br />

The most common mid victorian era <strong>Adelaide</strong> verandah was<br />

typically a concave (eyelash) profile with square timber with<br />

decorative mouldings. Later verandahs had a bullnosed profile<br />

and later still had turned timber posts. Even quite modest<br />

cottages had relatively ornate verandahs, which served to both<br />

shelter and decorate the house.<br />

HEIGHT & WIDTH<br />

Typically ‘<strong>Adelaide</strong>’ verandahs were about 2200-2300mm (7+ft)<br />

high, such that the underside of the fascia aligned with the<br />

transom over the front door. Sometimes the verandah had a<br />

frieze rail at this height when the overall height of the building<br />

and verandah was greater. The width varied from as narrow as<br />

1100mm to as wide as 2500mm, though a width in the range<br />

1500-1800mm (5-6ft) is common. Generally smaller lower<br />

cottages set close to the street had narrower verandahs and<br />

larger houses with substantial front gardens had wider<br />

verandahs.<br />

NOTE*<br />

The most common mistake with new verandah reinstatement is<br />

having the fascia too high, such that it is higher than the front<br />

door and the roof slope too shallow.<br />

SET-OUT APPROACH<br />

Generally verandahs were set out with posts spaced, such that<br />

the posts frame both the front door and the adjacent windows<br />

such that the windows appear to be in the centre of the span.<br />

A common mistake is to set the posts out at equal spans such<br />

that the post positions do not relate to the windows, and<br />

sometimes even end up partly in front of the windows.<br />

PAINTING<br />

<strong>Verandah</strong> roofs were often painted, even when the main roof was<br />

not painted (ie left unpainted galvanized iron). Thus it is<br />

appropriate to have a new galvanized/grey roof and a red or a<br />

traditional striped verandah. Alternatively, if a uni<strong>for</strong>m appearance<br />

is sought, the new or existing roof and verandah can be painted<br />

with a traditional micaceous (bridge) paint, which generally is<br />

dark grey and very long lasting.<br />

The underside of verandahs was invariably a light pastel green<br />

type colour, such as ‘Eau de Nil’(Water of the Nile) or the backing<br />

colour of canvas, ‘Opaline Green’.<br />

The original colour is often evident on the wall plate or splatters<br />

on the wall. Blue/grey green variants can be used, but a soft<br />

pastel colour that is restful on the eye is the key, as opposed to<br />

cream or white. The green colour is also considered to deter flys.<br />

All metal elements including gutters & cast iron should be<br />

painted with gloss enamel (rather than water based acrylic<br />

paint) to avoide rusting.<br />

STANDARD VERANDAH DETAILS<br />

page 3<br />

DRAWINGS PREPARED 30/6/07<br />

3 of 5<br />

ENQUIRIES 08 8203 7445


P O S T / F A S C I A H O U S I N G C O M B I N A T I O N S<br />

1 : 2 0<br />

FINE (12mm) BEADED<br />

A FASCIA, NOTCHED INTO B<br />

FASCIA /<br />

FRIEZE<br />

ALIGNED<br />

WITH<br />

UNDERSIDE<br />

OF<br />

TRANSOM<br />

post width<br />

post width<br />

A<br />

POST<br />

A<br />

cast iron corner<br />

bracket<br />

SMALL OGEE<br />

CAPITAL WITH<br />

BEAD<br />

A<br />

PLAIN POST<br />

BASE(TYPICAL)<br />

historically buried<br />

ROUNDED EDGE PLAIN<br />

CONCRETE BASE<br />

B<br />

N E C K M O U L D I N G S<br />

1 : 1<br />

12-24mm BEADED FASCIA<br />

A B<br />

cast iron corner bracket<br />

B<br />

B<br />

LARGE OGEE<br />

CAPITAL WITH<br />

SCOTIA<br />

SIMPLE<br />

BEVELL<br />

SKIRTING<br />

BLOCK<br />

(COMMON)<br />

65-70mm CANT<br />

BRICK EDGING WITH<br />

CUT & STRUCK 3:1<br />

(SAND:LIME)<br />

MORTAR<br />

5mm gap with<br />

silicone to protect<br />

from rotting<br />

GALVANIZED 'T' PIECE 'U' OR 'T' PIECE POST FIXING<br />

CONCEALED POST FIXING CONCEALED BY SKIRTNG BLOCKS<br />

C<br />

C<br />

STOP CHAMFERED BEVELLED<br />

FASCIA<br />

(bevel stops<br />

100mm short of<br />

corner bracket)<br />

frieze<br />

cast iron corner bracket<br />

with frieze running<br />

between posts<br />

C<br />

C<br />

SMALL BLOCK<br />

CAPITAL<br />

32 - 40mm 32 - 40mm<br />

C<br />

D<br />

D<br />

SQUARE FASCIA WITH TIMBER<br />

FRIEZE RAIL<br />

frieze<br />

frieze rail 60 x 60<br />

cast iron corner<br />

bracket<br />

STRAIGHT CHAMFER<br />

CURVED CHAMFER WITH<br />

A (COMMON) B STEP (COMMON) C<br />

LAMBS<br />

TOUNGE<br />

SKIRTING<br />

BLOCK<br />

(LESS<br />

COMMON)<br />

230mm BULLNOSE<br />

SLATE<br />

D<br />

D<br />

LARGE BLOCK<br />

CAPITAL<br />

305mm BULLNOSE SLATE<br />

INAPPROPRIATE PROPRIETARY<br />

CAST ALUMINIUM 'OFF THE SHELF'<br />

POST BASE<br />

(may be beaded or stop<br />

chamfered to outside face)<br />

~ 290 - 350<br />

TO MATCH HEIGHT<br />

OF CORNER BRACKET<br />

OGEE CHAMFER (RARE)<br />

CAST IRON ELEVATED POST<br />

SHOE<br />

(UN COMMON)<br />

C A P I T A L S<br />

1 : 1<br />

A<br />

C<br />

OGEE CAPITAL<br />

SMALL BLOCK CAPITAL<br />

VERANDAH BASE<br />

Generally verandah bases are set sufficiently below the front door<br />

threshold to allow <strong>for</strong> a vent to aid underfloor ventilation in the<br />

hallway. Sometimes the base did come up to the underside of a<br />

thick redgum threshold when heights didn’t allow <strong>for</strong> a vent<br />

underneath.<br />

Tiled verandahs always had an edging of either bullnose slate or<br />

cant (splayed) bricks on edge. It was often common <strong>for</strong> a simple<br />

smooth concrete type finish verandah with a gently curved edge.<br />

Bullnose slate edging was generally between 32 and 40mm<br />

(11/4”-11/2”) thick, and sometimes as much as 50mm (2”). The<br />

width was either 230mm (9”) OR 305mm (1ft).<br />

Cant brick edging had a 60mm splay and were about 65mm wide.<br />

Below the edging it was typically bluestone where it was<br />

exposed.<br />

The posts were generally centred on the edging.<br />

<strong>Verandah</strong>s were not always tiled; often a simpe red screed was<br />

laid within the border, or a square of tiles in front of the front door.<br />

Earlier and mid Victorian houses typically had pottery tiles, 6”<br />

wide square set on a diagonal in two colours, or hexagonal tiles<br />

with oatmeal squares within. Later Victorian houses generally had<br />

the red and cream or black octagon and dot tessellated tiles.<br />

Tiles should be laid with virtually no grout gap to emulate the<br />

traditional appearance of verandah tiles, and not look like a<br />

bathroom floor.<br />

TIMBER ELEMENT DIMENSIONS<br />

<strong>Verandah</strong> posts were typically 100mm (4”) thick. These typically<br />

need to be planed down to size from a standard 115mm post.<br />

Only larger villas had thicker posts up to 120mm.<br />

A common mistake is to use off the shelf 90mm posts, which<br />

appear too thin and ‘matchstick’-like.<br />

Fascias were typically about 220mm deep by 32-50mm thick.<br />

Typically fascias had a bead at the bottom, which was usually<br />

finer than off-the-shelf beaded fascias.<br />

50mm fascias were employed where the fascia was stop<br />

chamfered rather than beaded.<br />

Where a timber frieze rail and cast iron infill freize used on larger/<br />

higher houses, the facia had neither a bead nor a stop chamfer.<br />

CARPENTRY/CONSTRUCTION<br />

<strong>Verandah</strong> fascias were typically housed into the posts such that<br />

the posts appear to run up to the underside of the gutter with the<br />

scotia running between the posts.<br />

<strong>Verandah</strong> posts typically had concealed fixing to the verandah<br />

base rather than metal post shoes. Simple cottages had the posts<br />

set into the ground. To emulate this appearance a concealed ‘T’<br />

piece can be used. More substantial houses typically had a<br />

simple skirting block around the base with concealed metal<br />

fixings. Very rarely elevated cast iron post shoes were employed.<br />

STANDARD VERANDAH DETAILS<br />

page 4<br />

DRAWINGS PREPARED 30/6/07<br />

of 5<br />

4<br />

ENQUIRIES 08 8203 7445


B A S E P L A N S S E T O U T<br />

A<br />

B<br />

C<br />

D<br />

PLAIN CONCRETE WITH ROUNDED EDGE<br />

(TYPICALLY PAINTED RED) NOT SHOWN<br />

HARLEQUIN PATTERN 150mm SQUARE<br />

POTTERY TILES<br />

230mm cant<br />

bricks<br />

150mm EQUAL SIDED OCTAGON POTTERY<br />

TILE (NB NO TILE BORDER)<br />

300mm slate<br />

100mm UNEQUAL SIDED TESSELLATED<br />

TILE<br />

300mm slate<br />

A<br />

traditional galv<br />

skylight<br />

B<br />

C<br />

SINGLE POSTS SYMMETRICAL ABOUT DOOR AND WINDOW<br />

(SINGLE FRONTED AND ROW COTTAGES)<br />

800<br />

existing galv roof<br />

SINGLE POSTS SYMMETRICAL ABOUT DOORS AND WINDOWS<br />

(DOUBLE FRONTED COTTAGES AND MAISONETTES)<br />

DOUBLE POSTS SYMMETRICAL ABOUT DOOR AND WINDOW<br />

(LARGER VILLAS)<br />

D I V I D E R S C R E E N<br />

C A P P I N G S + R A I L S<br />

A<br />

B<br />

C<br />

A<br />

optional painted lead<br />

capping <strong>for</strong> weather<br />

protection<br />

D<br />

B<br />

MATERIALS (TIMBER SPECIES)<br />

<strong>Verandah</strong> posts were typically made of jarrah or Oregon. Fascias<br />

were typically Oregon. The use of perma-pine is generally<br />

inappropriate <strong>for</strong> verandahs as it is prone to splitting and twisting<br />

and typically comes in 90mm and other inappropriate<br />

dimensions. The use of LSOP (laminated timber) is not<br />

recommended as the laminated timber surface texture rather<br />

than the natural timber grain shows through the paint.<br />

VERANDAH ROOFS<br />

If the original verandah roof remains, it should generally be<br />

retained. <strong>Verandah</strong> roofs were very well built out of heavy deep<br />

profile iron and tank riveted <strong>for</strong> additional strength. Even if slightly<br />

damaged they can generally be repaired which is preferable to<br />

being replaced with new, relatively lighter guage iron. If the main<br />

house is re-roofed in Colorbond it is better to paint the original<br />

verandah to match rather than replace the verandah iron itself.<br />

Historically verandah roofs were designed to appear as canvas.<br />

The concave profile emulates the natural slump that canvas<br />

would have. In Victorian times it was typical <strong>for</strong> verandahs to be<br />

striped in alternate colours as canvas is often striped. The<br />

verandah roof sheets were 8 flute rather than 10 flute. If the iron<br />

is replaced it is preferable to utilize 8 flute (rainwater) tank iron so<br />

that if the verandah is ever painted in stripes the stripes will be<br />

the correct width and set out across the width of the verandah.<br />

<strong>Verandah</strong> gutters should be ogee profile and narrower (100mm)<br />

than the main roof gutters, such that the gutter is refolded 50mm<br />

narrower than a standard gutter.<br />

<strong>Verandah</strong> downpipes were typically 50mm metal and cranked<br />

from the back around the quoins to connect into the main roof<br />

downpipes, which were typically set around the side behind the<br />

quoin. This configuration avoids the downpipes clashing with the<br />

post mouldings.<br />

COMMONLY REPEATED MISTAKES IN NEW VERANDAHS<br />

!<strong>Verandah</strong> posts too thin, 90mm<br />

!<strong>Verandah</strong> too high<br />

!Posts set at equal spans<br />

!<strong>Verandah</strong> base too high<br />

!Standard gutters rather than 100mm refolded ogee gutter<br />

!Tiling to the edge without a slate or brick border<br />

RARE VARIATIONS<br />

<strong>Verandah</strong>s occasionally had additional entry statements, such as<br />

a gablet over the entrance.<br />

STANDARD VERANDAH DETAILS<br />

page 5<br />

DRAWINGS PREPARED 30/6/07<br />

5 of 5<br />

ENQUIRIES 08 8203 7445


ADELAIDE VERANDAHS<br />

Victorian Period pre 1900<br />

PROPERTY DETAILS<br />

Owner:<br />

Contact Details:<br />

Property Address:<br />

maisonette row other:<br />

cottage<br />

double fronted<br />

cottage<br />

single fronted<br />

cottage<br />

House Type:<br />

VERANDAH SPECIFICATIONS (circle one <strong>for</strong> each element)<br />

This specification is to be completed with reference to and in accordance with <strong>Adelaide</strong> <strong>City</strong> Council's "<strong>Adelaide</strong> Standard <strong>Verandah</strong>" standard drawings.<br />

The verandah design should be, where possible, based on historical/ physical evidence. Any original remnants should be retained and incorporated into<br />

the new verandah. Contact <strong>Adelaide</strong> <strong>City</strong> Council's <strong>Heritage</strong> department on (08) 8203 7445 if you have any queries.<br />

ROOF PROFILE<br />

A B C D E<br />

POST WIDTH (mm)<br />

96 100 120 (other):<br />

END PANAL<br />

A B B varient<br />

BRACKETS<br />

A B C D E<br />

DIVIDER SCREEN<br />

A B C<br />

FASCIA TYPE<br />

A B C D<br />

TRANSOM UNDERSIDE HEIGHT mm FASCIA / FRIEZE UNDERSIDE HEIGHT mm<br />

CAPITAL TYPE<br />

A B C D<br />

CHAMFER TYPE<br />

A B C<br />

POST BASE TYPE<br />

A B C D<br />

VERANDAH BASE TYPE A B C D<br />

NECK MOULDINGS<br />

A B C<br />

BASE PLAN<br />

A B C D<br />

DIVIDER SCREEN CAPPINGS A B<br />

DIVIDER SCREEN RAILS A B C D<br />

DIAGRAM OF PROPOSED PLAN AND ELEVATION (2 squares = 1 metre)<br />

STANDARD VERANDAH DETAILS<br />

Pro<strong>for</strong>ma<br />

DRAWINGS PREPARED 30/6/07<br />

of 5<br />

ENQUIRIES 08 8203 7445


ADELAIDE VERANDAHS<br />

Victorian Period pre 1900<br />

PROPERTY DETAILS<br />

john smith<br />

Owner:<br />

8333 3333<br />

Contact Details:<br />

30 smith street 5000<br />

Property Address:<br />

maisonette row other:<br />

cottage<br />

double fronted<br />

cottage<br />

single fronted<br />

cottage<br />

House Type:<br />

VERANDAH SPECIFICATIONS (circle one <strong>for</strong> each element)<br />

This specification is to be completed with reference to and in accordance with <strong>Adelaide</strong> <strong>City</strong> Council's "<strong>Adelaide</strong> Standard <strong>Verandah</strong>" standard drawings.<br />

The verandah design should be, where possible, based on historical/ physical evidence. Any original remnants should be retained and incorporated into<br />

the new verandah. Contact <strong>Adelaide</strong> <strong>City</strong> Council's <strong>Heritage</strong> department on (08) 8203 7445 if you have any queries.<br />

ROOF PROFILE<br />

A B C D E<br />

POST WIDTH (mm)<br />

96 100 120 (other):<br />

END PANAL<br />

A B B varient<br />

BRACKETS<br />

A B C D E<br />

DIVIDER SCREEN<br />

A B C<br />

FASCIA TYPE<br />

A B C D<br />

TRANSOM UNDERSIDE HEIGHT 2400 mm FASCIA / FRIEZE UNDERSIDE HEIGHT 2400 mm<br />

CAPITAL TYPE<br />

A B C D<br />

CHAMFER TYPE<br />

A B C<br />

POST BASE TYPE<br />

A B C D<br />

VERANDAH BASE TYPE A B C D<br />

NECK MOULDINGS<br />

A B C<br />

BASE PLAN<br />

A B C D<br />

DIVIDER SCREEN CAPPINGS A B<br />

DIVIDER SCREEN RAILS A B C D<br />

DIAGRAM OF PROPOSED PLAN AND ELEVATION (2 squares = 1 metre)<br />

STANDARD VERANDAH DETAILS<br />

PROFORMA filled out<br />

DRAWINGS PREPARED 30/6/07<br />

of 5<br />

ENQUIRIES 08 8203 7445