Max. length of suction pipe [m]<br />
The chart below is a guide to the maximum length of the<br />
suction pipe depending on the flow capacity of the oil and<br />
the inner pipe diameter. It is assumed that the safety height<br />
The stated values are valid for a suction pipe without pipe<br />
bends/elbows, including the resistance values of the <strong>valve</strong>s<br />
(diaphragm <strong>anti</strong> <strong>siphon</strong> <strong>valve</strong> and filter/”Toc-Duo”) illustrated<br />
in the example of installation. When using the maximum<br />
possible length of the suction pipe, then the burner pump<br />
has to produce an underlying pressure of about –0.4 bar.<br />
Example of installation:<br />
”Flexo-Bloc”<br />
Tank<br />
Subject to technical modification without notice.<br />
Product range 9<br />
ti 101-1/10/10.2001/MW.<br />
<strong>Diaphragm</strong> <strong>anti</strong> <strong>siphon</strong> <strong>valve</strong> ”Oilstop V”<br />
In two pipe systems:<br />
Return pipe with<br />
free drain-off in the tank<br />
inner pipe diameter<br />
10 mm<br />
Suction pipe<br />
Return pipe<br />
Suction pipe<br />
OVENTROP UK LTD.<br />
Unit I – The Loddon Centre<br />
Wade Road<br />
Basingstoke, Hampshire RG24 8FL<br />
Telephone (01256) 330441<br />
Telefax (Sales) (01256) 330525<br />
Telefax (General) (01256) 470970<br />
E-Mail sales@oventrop.co.uk<br />
set at the handwheel corresponds to the actual height<br />
difference ∆hv.<br />
inner pipe diameter 13 mm<br />
Flow capacity of oil [l/h]<br />
Pipe bends/elbows, isolation- and change-over <strong>valve</strong>s or<br />
other installations in the suction pipe between the diaphragm<br />
<strong>anti</strong> <strong>siphon</strong> <strong>valve</strong> and the burner as well as oil of low<br />
temperature (underground tanks, unheated storage rooms,<br />
pipes installed outside, etc.) will mean additional pressure<br />
loss. Any such installations can reduce the maximum<br />
possible length of the suction pipe considerably, when<br />
compared with the values illustrated in the chart.<br />
”Toc-Duo”<br />
Burner<br />
Burner<br />
F. W. OVENTROP GmbH & Co. KG<br />
Paul-<strong>Oventrop</strong>-Straße 1<br />
D-59939 Olsberg<br />
Telephone (02962) 82-0<br />
Telefax (02962) 82405<br />
Internet http://www.oventrop.de<br />
eMail mail@oventrop.de<br />
9.2-2 1/2002<br />
Filter<br />
One pipe system<br />
Two pipe system<br />
∆h v (safety height) 1 to 4 m<br />