90<br />

1360<br />

ELECTRICAL SHOP SUPPLIES<br />

FANS<br />

EXHAUST FANS<br />

Heavy duty steel exhaust fans for industrial and commercial<br />

use. All fans feature 115 volt totally enclosed<br />

continuous run motors with built-in overload protection.<br />

Available in two styles: Panel series, used when<br />

moving air within an enclosed area; Exhaust series,<br />

when exhausting air to the outdoors. The exhaust<br />

series comes equipped with aluminum louvres which<br />

opens automatically when fan is operating. Both<br />

series are CSA approved. Back protection guards are<br />

included on 12 inch fans for both series. All other<br />

guards optional. 2 speed fans require switch #<br />

BA085 and variable speed fans require switch<br />

#BA058.<br />

FAN GUARDS<br />

ECONOMICAL CEILING FANS<br />

Prevent Heat Loss in your plant, cut fuel costs by up to 30%. Increase employee productivity<br />

with these economical ceiling fans.<br />

For: manufacturing plants, warehouses, repair shops, aircraft hangers, restaurants,<br />

indoor tennis courts, auditoriums.<br />

• Recirculates hot air and heat from ceiling down to floor and work area<br />

• Use wasted heat from production processes and lighting systems<br />

• Air movement in summer reduces humidity and temperature 8° (chill effect)<br />

• Readily installed, uses 110v/60Hz<br />

Model Fan C.F.M. Floor Area<br />

No. Dia." Air Del. Covered<br />

BA152 36 7,100 600 cu.ft.<br />

BA154 48 13,000 900 cu.ft.<br />

BA156 56 20,500 1,500 cu.ft.<br />

CONTROLS<br />

BA186 Variable Speed Controls 1 Fan<br />

BA187 Variable Speed Controls up to 3 Fans<br />

BA185 Variable Speed Controls up to 10 Fans<br />

The use of fan guards is compulsory unless the fan is installed out of<br />

reach at least 8 feet from the floor or ground. Fans must<br />

be guarded on both sides, front and back when mounted<br />

below 8'.<br />

B<br />

PANEL EXHAUST<br />

Fan Model Dimensions Model Dimensions Free Air<br />

Dia." No. A" B"(Max) No. A" B" C" D" RPM HP CFM<br />

STANDARD<br />

12 BA059 17 11 1/2 BA129 17 14 6 3/4 11 1/2 1725 1/4 1450<br />

14 BA062 18 3/4 11 1/2 BA132 18 3/4 15 3/4 6 3/4 11 1/2 1725 1/4 2200<br />

16 BA064 20 3/4 11 1/2 BA135 20 3/4 17 3/4 6 3/4 11 1/2 1725 1/4 3300<br />

18 BA067 22 3/4 11 1/2 BA138 22 3/4 19 3/4 6 3/4 11 1/2 1725 1/4 4300<br />

20 BA070 24 3/4 12 1/4 BA141 24 3/4 21 3/4 6 3/4 12 1/4 1725 1/3 5000<br />

2 SPEED HIGH/LOW<br />

12 BA482 17 11 1/2 BA130 17 14 6 3/4 11 1/2 1725/1140 1/4 1450/1000<br />

14 BA483 18 3/4 11 1/2 BA133 18 3/4 15 3/4 6 3/4 11 1/2 1725/1140 1/4 2200/1450<br />

16 BA484 20 3/4 11 1/2 BA136 20 3/4 17 3/4 6 3/4 11 1/2 1725/1140 1/4 3300/2100<br />

18 BA485 22 3/4 11 1/2 BA139 22 3/4 19 3/4 6 3/4 11 1/2 1725/1140 1/4 4300/2850<br />

20 BA486 24 3/4 12 1/4 BA142 24 3/4 21 3/4 6 3/4 12 1/4 1725/1140 1/3 5000/3250<br />

24 BA487 28 3/4 12 1/4 BA495 28 3/4 25 3/4 6 3/4 12 1/4 1100/800 1/3 5000/3000<br />

VARIABLE RATE AT HIGH<br />

12 BA060 17 11 1/2 BA490 17 14 6 3/4 11 1/2 1625 1/4 1370<br />

14 BA488 18 3/4 11 1/2 BA491 18 3/4 15 3/4 6 3/4 11 1/2 1625 1/4 2070<br />

16 BA065 20 3/4 11 1/2 BA492 20 3/4 17 3/4 6 3/4 11 1/2 1625 1/4 3110<br />

18 BA068 22 3/4 11 1/2 BA493 22 3/4 19 3/4 6 3/4 11 1/2 1625 1/4 4050<br />

20 BA489 24 3/4 12 1/4 BA494 24 3/4 21 3/4 6 3/4 12 1/4 1625 1/3 4700<br />

24 BA073 28 3/4 12 1/4 BA145 28 3/4 25 3/4 6 3/4 12 1/4 1625 1/3 5170<br />

SMOKE EJECTORS<br />

Remove smoke, welding fumes and undesirable contaminants from the air or bring clean air in. Reversible smoke ejectors are equipped with a<br />

totally enclosed ball bearing motor with automatic overload protection. Units are CSA approved. Explosion proof models in accordance with Class<br />

1 Group D/Class II Group EFG. All are 115 VAC, 1/3 H.P., 1725 RPM equipped with a 6 foot power cord, cord holder and cadmium plated protection<br />

guards. Hoses are fire safe, single ply, neoprene impregnated nylon.<br />

Model CFM Fan Dim.<br />

No. Type @.10"SP L" x W" x H"<br />

BA099 Standard 1620 16 x 14 5/8 x 14 5/8<br />

BA100 Exp. Proof 1620 16 x 14 5/8 x 14 5/8<br />

BA101 Standard 3050 13 5/8 x 18 1/2 x 18 1/2<br />

BA102 Exp. Proof 3050 13 5/8 x 18 1/2 x 18 1/2<br />

BA103 Standard 3700 14 3/8 x 21 x 21<br />

BA104 Exp. Proof 3700 14 3/8 x 21 x 21<br />

COLLAR ADAPTORS<br />

Model Fan<br />

No. Size"<br />

BA026 12<br />

BA028 16<br />

BA029 18<br />

OPTIONAL GUARDS<br />

FRONT GUARD BACK GUARD<br />

Fan Model Model<br />

Dia. No. No.<br />

12 BA496 -<br />

14 BA497 BA502<br />

16 BA498 BA503<br />

18 BA499 BA504<br />

20 BA500 BA505<br />

24 BA501 BA506<br />

FLEXIBLE HOSES<br />

Model<br />

No. Length' Dia."<br />

BA049 15 12<br />

BA050 20 16<br />

BA051 20 18<br />

D<br />

C<br />

B<br />

A<br />

DIMENSIONS<br />

A<br />

Panel Fan<br />

Exhaust Fan<br />

A