SEALING THE TRIM PANELS<br />

It is necessary to seal trim panels against the<br />

stove and against the fireplace front. This will<br />

prevent the loss of warm room air up the<br />

chimney.<br />

1. (See Figure 9) Using the caulking gun and<br />

a cartridge of RTV silicone, run a bead of<br />

silicone all the way around the inside of the<br />

trim panels next to the stove.<br />

2. (See Figure 10) Attach 1 1/2" x 2" strip insulation<br />

around the back edge of the trim<br />

panels. Set the strip back 1" from the edge.<br />

NOTE: On rock face fireplaces, it may be<br />

necessary to add additional pieces of<br />

fiberglass to fill large or deep mortar joints.<br />

FINAL STEP<br />

1. Slide the stove back into the fireplace. Be<br />

sure the trim panels all tit snugly against the<br />

face of the fireplace. NOTE: Be sure the top<br />

edge of the trim panel runs true with the<br />

mortar joints on a brick fireplace. It it does not,<br />

one side of the stove can be shimmed from<br />

the bottom with metal to give a "square"<br />

appearance.<br />

2. Place a flashlight up through the damper<br />

and onto the top of the stove. Visually check<br />

all the way around the trim panels for evidence<br />

of light seepage. Any seepage should be<br />

blocked with the use of additional fiberglass<br />

and RTV silicone until a tight seal is achieved.<br />

(See Figure 10)<br />

Page 11<br />

FIGURE9<br />

FIGURE 10<br />

Standard Caulking Gun<br />

SEALING TRIM PANELS<br />

Insulafion Strip<br />

ATTACHING<br />

INSULATING STRIPS