Numbering diagram for the multiple <strong>of</strong><br />

the first group selector at Bogota Centro<br />

I six digit numbering<br />

II five digit numbering<br />

76<br />

quench problems. At the same time the high transmission voltage allows the<br />

use <strong>of</strong> smaller wire gauge, important for an extended local network as that<br />

in Bogota. In non-operated condition the voltage on the subscriber's line is<br />

24 V. Guaranteed operating limits are 22 and 26 V.<br />

Release <strong>of</strong> a connection takes place from the calling subscriber only (A-subscriber).<br />

Should, however, the called subscriber (B-subscriber) omit to replace<br />

his receiver, the A-subscriber will be released but the connecting circuit remains.<br />

In this way possible malicious calls may be traced. Should the B-subscriber<br />

only replace his receiver both subscribers will remain connected and<br />

an alarm will be issued in the exchange after a certain time.<br />

The trunk final selector tots on a local call in progress and the operator may<br />

break in on this call, disconnect the subscriber not required and establish the<br />

trunk call connection. The operator cannot, however, break in on a trunk call<br />

in progress.<br />

The exchanges are equipped with traffic meters normally operated once for<br />

each completed call. For calls to one or more <strong>of</strong> the special services the<br />

metering may be suppressed as required by the administration. The system has<br />

provisions for introducing repeated counting during a call.<br />

For cashing charges in coin box instruments the link circuit has been arranged<br />

with current reversal on the calling line, when the called subscriber is<br />

answering. The current reversal is omitted for calls to special services which<br />

are not to be charged.<br />

A number <strong>of</strong> 500-groups in each exchange has been arranged for PBX-subscribers<br />

i. e. they have been provided with final selectors allowing free hunting<br />

over a number <strong>of</strong> consecutive lines. These lines may also be called individually<br />

for night service connections to the extensions in the private branch exchanges.