CONTROL PANEL MENU DISPLAY<br />

The control panel consists of four main menus. These menus are; Set Temperature, System, Lite+ and Tools. The Lite+ menu will only appear if<br />

the spa is equipped with an optional multicolor light (if equipped with the optional multicolor light, use the reference card provided with the light for<br />

operating instructions).<br />

Press the MODE ▲ or MODE ▼ button to scroll through the main menus. Once the desired menu is illustrated, press the ON ▲ button to activate<br />

the menu.<br />

TEMPERATURE CONTROL<br />

Set Temperature Display<br />

The set temperature range is from 80°F to 104°F (27°C to 40°C). Higher temperatures can be reached by using<br />

one of four codes: ut-1, ut-2, ut-3 and ut-4. These settings get progressively warmer, with ut-4 the highest at<br />

approximately 106°F (41°C). (The temperature of any setting may rise slightly depending on the current use and<br />

condition of your spa, and on outside temperature.)<br />

The set temperature of the spa water will automatically be 102°F (39°C) the first time power is applied. This is the<br />

setting programmed at the factory. After the spa has been set up and used, the last temperature value set by the<br />

user will be stored in memory. If power is disconnected from the spa, it will automatically revert to the last set temperature when power is<br />

reapplied.<br />

To display the set temperature of the spa, press the ON ▲ button. The set temperature will be displayed, unless the spa is locked (in which case<br />

the lock icon is displayed). The set temperature display will automatically shut off after 30 seconds.<br />

To increase the set temperature of the spa water, press ON ▲ button. Each time the button is pressed, the set temperature display will increment<br />

by one degree. If the button is held down, the set temperature display will increase by one degree every half-second.<br />

To decrease the set temperature of the spa water, press the OFF ▼ button . Each time the button is pressed, the set temperature display will<br />

decrement by one degree. If the button is held down, the set temperature display will decrease by one degree every half-second.<br />

If the set temperature value will not change, check the TEMPERATURE LOCK and SPA LOCK features. When either of these features is applied,<br />

the temperature control is disabled. To activate the temperature control buttons, remove all locking features applied.<br />

SYSTEM MODE<br />

System Display Active<br />

Your <strong>Tiger</strong> River spa is equipped with a System Mode. This function will allow you to conveniently turn the jet(s)<br />

on high speed and the light on maximum intensity at the same time.<br />

To activate the system mode, perform the following functions:<br />

Press the MODE ▲ button until the SYSTM symbol is illuminated on the display. The jets and light icons will flash<br />

until the system mode is activated. Press the ON ▲ button to activate the SYSTM mode feature.<br />

NOTE: Once activated, the jet and light functions can still be changed by pressing the JETS or LIGHT button.<br />

To deactivate the system mode, press the MODE ▲ button until the SYSTM symbol is illuminated on the display. Press the OFF ▼ button to<br />

deactivate.<br />

TOOLS MENU<br />

Tools Display<br />

The TOOLS menu is one of the main menus on the control panel. Within the TOOLS menu are six submenus, which<br />

consists of; Clean, Temp Lock, Spa Lock, Summer Timer and Exit.<br />

To enter into the TOOLS menu, scroll through the main menus using the MODE ▲ or MODE ▼ button until the<br />

TOOLS menu is illustrated. Press the ON ▲ button to enter into the TOOLS submenu, use the MODE ▲ or<br />

MODE ▼ button to scroll through the submenus. Once the desired submenu is illustrated, press the ON ▲ button<br />

to activate the submenu or press the OFF ▼ button to deactivate the submenu. To leave the TOOLS submenu, scroll through the submenu until<br />

EXIT is illustrated, press the ON ▲ button to exit the submenu.<br />

CLEANING MODE<br />

Clean Cycle Active<br />

All <strong>Tiger</strong> River spas are equipped with a “Cleaning” mode. When the mode is activated, the jet pump in the first jet<br />

system will turn on and run for ten minutes (used for water maintenance). To activate the “Cleaning" mode, press<br />

the MODE ▲ or MODE ▼ button until the TOOLS menu is illustrated. Then press the ON ▲ button to enter the<br />

TOOLS submenus. The CLEAN symbol will illuminated (the CLEAN mode is the first submenu) on the display.<br />

Press the ON ▲ button to activate the CLEAN mode feature.<br />

NOTE: The jet icon will remain solid in the CLEAN display and will flash on and off in the main display while the “Cleaning ” mode is active.<br />

To stop the Cleaning Cycle before the ten minutes is complete, Press the MODE ▲ button until the TOOLS menu is illuminated then press the ON<br />

button to enter the TOOLS submenus where the CLEAN symbol is illuminated on the display. Press the OFF ▼ button to deactivate.<br />

NOTE: Pressing the JETS button will also deactivate the clean cycle.<br />

Control Panel Operations<br />

Page 26

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!