Typical Physical Properties<br />
Temperature Continuous max. +1832°F (1000°C)<br />
Pressure 1 psig (bar) <strong>4122</strong>-<strong>FC</strong><br />
<strong>4122</strong>-CMG<br />
<strong>4122</strong>-KAMM<br />
P x T, max. 2 <strong>4122</strong>-<strong>FC</strong><br />
psig x °F (bar x °F) <strong>4122</strong>-CMG<br />
<strong>4122</strong>-KAMM<br />
Notes:<br />
1. Based on ANSI RF flanges at our preferred torque. When approaching maximum pressure, continuous<br />
operating temperature, minimum temperature or 50% of maximum PxT, consult Garlock Engineering.<br />
2. PxT = psig x ºF (bar x ºC)<br />
* This is a general guide and should not be the sole means of selecting or rejecting this material. ASTM<br />
test results in accordance with ASTM F-104; properties based on 1/16" (1.6mm) gasket thickness unless<br />
otherwise mentioned.<br />
Residdual<br />
Mass (%)<br />
Typical Physical Properties for <strong>4122</strong>-<strong>FC</strong>*:<br />
ASTM Test Method F36<br />
Compressibility, range, %<br />
Recovery %<br />
ASTM F38<br />
Creep Relaxation, %<br />
ASTM F152<br />
Tensile, w/insert, psi (N/mm2 )<br />
ASTM F1315<br />
Density, lbs./ft3 (grams/cm3 )<br />
ASTM D149<br />
Dielectric Properties, volts/mil.<br />
100<br />
98<br />
96<br />
94<br />
92<br />
90<br />
88<br />
Weight Loss Testing (TGA¹)<br />
<strong>THERMa</strong>-PUR<br />
Vermiculite Gasket<br />
¹TGA—thermal gravimetric analysis in oxygen atmosphere<br />
@ 80°F to 1650°F with 30min hold at max temperature<br />
AUTHORIZED REPRESENTATIVE<br />
Garlock Sealing Technologies<br />
1666 Division Street<br />
Palmyra, New York 14522 USA<br />
1-315-597-4811<br />
1-800-448-6688<br />
Fax: 1-800-543-0598<br />
1-315-597-3039<br />
www.garlock.com<br />
<strong>THERMa</strong>-PUR<br />
maintained 95% of<br />
it's original weight<br />
Vermiculite Gasket<br />
lost 10% of its<br />
original weight<br />
0 200 400 600 800 1000 1200 1400 1600<br />
Temperature ( F)<br />
500 (34.5)<br />
1000 (68.9)<br />
Equal to flange rating<br />
150,000 (5,100)<br />
600,000 (21,500)<br />
Equal to flange rating<br />
35-45<br />
18<br />
25<br />
1,500 (10.34)<br />
95 (1.52)<br />
100<br />
Low Weight Loss<br />
<strong>THERMa</strong>-PUR<br />
proprietary<br />
formulation<br />
resists oxidation<br />
and has improved<br />
weight loss property<br />
by almost 2X<br />
when compared to<br />
other high temp<br />
organic based gasket<br />
such as graphite<br />
and vermaculite<br />
<strong>THERMa</strong>-PUR out performed vermiculite based gaskets in laboratory<br />
testing † . <strong>THERMa</strong>-PUR showed significantly less leakage even in<br />
extreme thermal cycling condition † Out Performs<br />
For test details, please contact Garlock Engineering<br />
2008 RECIPIENT OF<br />
ENVIRONMENTAL<br />
PROTECTION AGENCY’S<br />
W<strong>AR</strong>NING:<br />
Properties/applications shown throughout this brochure are typical. Your specific<br />
application should not be undertaken without independent study and evaluation<br />
for suitability. For specific application recommendations consult Garlock.<br />
Failure to select the proper sealing products could result in property damage<br />
and/or serious personal injury.<br />
Performance data published in this brochure has been developed from field<br />
testing, customer field reports and/or in-house testing.<br />
While the utmost care has been used in compiling this brochure, we assume no<br />
responsibility for errors. Specifications subject to change without notice. This<br />
edition cancels all previous issues. Subject to change without notice.<br />
Garlock Sealing Technologies, LLC is a registered trademark for packings,<br />
seals, gaskets, and other products of Garlock.<br />
© Garlock Sealing Technologies, LLC 2011. All rights reserved worldwide.<br />
Other facilities within the Garlock family companies are located in:<br />
Columbia, SC, USA Phone 1.803.783.1880 Fax 1.803.783.4279<br />
Houston, TX, USA Phone 1.315.597.4811 Fax 1.315.597.3216<br />
Houston, TX, USA Phone 1.713.747.6948 Fax 1.713.747.6029<br />
Denver, CO, USA Phone 1.303.988.1242 Fax 1.303.988.1922<br />
Sydney, Australia Phone 61.2.9793.2511 Fax 61.2.9793.2544<br />
Auckland, New Zealand Phone 64.9573.5651 Fax 64.9573.5636<br />
São Paulo, Brazil Phone 55.11.4352.6161 Fax 55.11.4352.8181<br />
Sherbrooke, Canada Phone 1.819.563.8080 Fax 1.819.563.5620<br />
W. Yorkshire, England Phone 44.1422.313600 Fax 44.1422.313601<br />
Saint-Étienne, France Phone 33.4.7743.5100 Fax 33.4.7743.5151<br />
Neuss, Germany Phone 49.2131.3490 Fax 49.2131.349.222<br />
Mexico City, Mexico Phone 52.55.5078.4600 Fax 52.55.5368.0418<br />
Singapore Phone 65.6285.9322 Fax 65.6284.5843<br />
Shanghai, China Phone 86.021.64544412 Fax 86.021.34080906<br />
Dubai, UAE Phone 971.4.8833652 Fax 971.4.8833682<br />
Pune, India Phone 91.20.3061.6608 Fax: 91.20.3061.6699<br />
GSK 3:78 VIA-07/2011