<strong>1800B2</strong> <strong>and</strong> <strong>1800B2</strong>-<strong>HC</strong> <strong>Series</strong> <strong>Service</strong> <strong>Regulators</strong> 06 <strong>Elster</strong> American Meter<br />

<strong>1800B2</strong> Regulator Capacity Performance<br />

1-1/4" Outlet<br />

Set Point 7.0" W.C.<br />

at 50 SCFH<br />

SCFH (m 3 /h) 0.60 specific gravity<br />

gas at 60°F <strong>and</strong> 14.7 PSIA. Pressure<br />

spring 70017P044. Outlet pressure<br />

variance not to exceed +2" -1" W.C.<br />

from set point, horizontal position.<br />

3/4" Outlet<br />

Set Point 2 PSIG<br />

at 50 SCFH<br />

SCFH (m 3 /h) 0.60 specific gravity<br />

gas at 60°F <strong>and</strong> 14.7 PSIA. Pressure<br />

spring 70017P049. Outlet pressure<br />

variance not to exceed +/- 10%<br />

from set point, horizontal position.<br />

<strong>1800B2</strong> <strong>Series</strong> Regulator Capacity SCFH (m 3 /h)<br />

Inlet<br />

PSIG<br />

(bar)<br />

1<br />

(0.07)<br />

2<br />

(0.14)<br />

3<br />

(0.21)<br />

5<br />

(0.34)<br />

10<br />

(0.70)<br />

15<br />

(1.00)<br />

20<br />

(1.40)<br />

30<br />

(2.10)<br />

40<br />

(2.80)<br />

60<br />

(4.10)<br />

100<br />

(6.90)<br />

1/8" x 3/16"<br />

Orifice<br />

—<br />

175<br />

(5.0)<br />

225<br />

(6.4)<br />

275<br />

(7.8)<br />

375<br />

(10.6)<br />

450<br />

(12.7)<br />

500<br />

(14.2)<br />

650<br />

(18.4)<br />

800<br />

(22.7)<br />

1100<br />

(31.2)<br />

1700<br />

(48.1)<br />

3/16"<br />

Orifice<br />

150<br />

(4.2)<br />

250<br />

(7.1)<br />

325<br />

(9.2)<br />

475<br />

(13.4)<br />

800<br />

(22.7)<br />

1000<br />

(28.3)<br />

1200<br />

(34.0)<br />

1600<br />

(45.3)<br />

1900<br />

(53.8)<br />

1/4"<br />

Orifice<br />

200<br />

(5.7)<br />

350<br />

(9.9)<br />

475<br />

(13.4)<br />

750<br />

(21.2)<br />

1500<br />

(42.5)<br />

1800<br />

(51.0)<br />

2100<br />

(59.5)<br />

2500<br />

(70.8)<br />

5/16"<br />

Orifice<br />

275<br />

(7.8)<br />

475<br />

(13.4)<br />

550<br />

(15.6)<br />

1000<br />

(28.3)<br />

2200<br />

(62.3)<br />

2500<br />

(70.8)<br />

2500<br />

(70.8)<br />

3/8"<br />

Orifice<br />

350<br />

(9.9)<br />

500<br />

(14.2)<br />

700<br />

(19.8)<br />

1200<br />

(34.0)<br />

2500<br />

(70.8)<br />

2500<br />

(70.8)<br />

2500<br />

(70.8)<br />

1/2"<br />

Orifice<br />

400<br />

(11.3)<br />

650<br />

(18.4)<br />

1000<br />

(28.3)<br />

2000<br />

(56.6)<br />

2500<br />

(70.8)<br />

2500<br />

(70.8)<br />

9/16"<br />

Orifice<br />

400<br />

(11.3)<br />

900<br />

(25.5)<br />

1500<br />

(42.5)<br />

2500<br />

(70.8)<br />

2500<br />

(70.8)<br />

2500<br />

(70.8)<br />

— —<br />

— — — —<br />

— — — — —<br />

— — — — — —<br />

— — — — — —<br />

For optimum performance, maximum inlet pressure should not exceed maximum capacity rating for any given<br />

orifice size.<br />

<strong>1800B2</strong> <strong>Series</strong> Regulator Capacity SCFH (m 3 /h)<br />

Inlet<br />

PSIG<br />

(bar)<br />

3<br />

(0.21)<br />

5<br />

(0.34)<br />

10<br />

(0.70)<br />

15<br />

(1.00)<br />

20<br />

(1.40)<br />

30<br />

(2.10)<br />

40<br />

(2.80)<br />

60<br />

(4.10)<br />

100<br />

(6.90)<br />

125<br />

(8.60)<br />

1/8" x 3/16"<br />

Orifice<br />

—<br />

200<br />

(5.7)<br />

325<br />

(9.2)<br />

425<br />

(12.0)<br />

500<br />

(14.2)<br />

600<br />

(17.0)<br />

750<br />

(21.2)<br />

1100<br />

(31.2)<br />

1600<br />

(45.3)<br />

2000<br />

(56.6)<br />

3/16"<br />

Orifice<br />

200<br />

(5.7)<br />

300<br />

(8.5)<br />

450<br />

(12.7)<br />

600<br />

(17.0)<br />

750<br />

(21.2)<br />

950<br />

(26.9)<br />

1200<br />

(34.0)<br />

1600<br />

(45.3)<br />

2200<br />

(62.3)<br />

1/4"<br />

Orifice<br />

225<br />

(6.4)<br />

375<br />

(10.6)<br />

600<br />

(17.0)<br />

800<br />

(22.7)<br />

1000<br />

(28.3)<br />

1300<br />

(36.8)<br />

1600<br />

(45.3)<br />

2100<br />

(59.5)<br />

2500<br />

(70.8)<br />

5/16"<br />

Orifice<br />

275<br />

(7.8)<br />

475<br />

(13.4)<br />

750<br />

(21.2)<br />

1000<br />

(28.3)<br />

1200<br />

(34.0)<br />

1600<br />

(45.3)<br />

1900<br />

(53.8)<br />

2300<br />

(65.1)<br />

3/8"<br />

Orifice<br />

300<br />

(8.5)<br />

475<br />

(13.4)<br />

800<br />

(22.7)<br />

1000<br />

(28.3)<br />

1300<br />

(36.8)<br />

1700<br />

(48.1)<br />

2100<br />

(59.5)<br />

2500<br />

(70.8)<br />

1/2"<br />

Orifice<br />

375<br />

(10.6)<br />

600<br />

(17.0)<br />

1100<br />

(31.2)<br />

1400<br />

(39.6)<br />

1600<br />

(45.3)<br />

2300<br />

(65.1)<br />

2500<br />

(70.8)<br />

9/16"<br />

Orifice<br />

450<br />

(12.7)<br />

700<br />

(19.8)<br />

1200<br />

(34.0)<br />

1500<br />

(42.5)<br />

1800<br />

(51.0)<br />

—<br />

—<br />

— —<br />

— — — —<br />

— — — — — —<br />

For optimum performance, maximum inlet pressure should not exceed maximum capacity rating for any given<br />

orifice size.