Promains Pty Ltd - Water Services Association of Australia
Promains Pty Ltd - Water Services Association of Australia
Promains Pty Ltd - Water Services Association of Australia
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
WSAA Product Appraisal 11/29 Part 3 42<br />
Characteristic Standard Clause Requirement Frequency<br />
Specific initial<br />
longitudinal<br />
compressive<br />
modulus<br />
COUPLINGS<br />
Coupling Type Tests<br />
Performance<br />
ISO 25780 5.6<br />
ISO 25780 7.5.2<br />
ISO 25780 7.5.3<br />
ISO 25780 7.5.4<br />
ISO 25780 7.5.5<br />
Determine the<br />
specific initial<br />
longitudinal<br />
compressive<br />
modulus<br />
Leak Tightness when<br />
subjected to an<br />
extenal pressure<br />
differential<br />
Leak Tightness when<br />
subjected to internal<br />
positive pressure<br />
following assembly<br />
Leak Tightness when<br />
simultaneously<br />
subjected to angular<br />
deflection and draw<br />
Leak Tightness when<br />
simultaneously<br />
subjected to<br />
misalignment and<br />
draw under static<br />
AS PER QUALITY PLAN<br />
COPYRIGHT<br />
Test<br />
Result<br />
Standard<br />
Result<br />
Pipe Size Doc ID<br />
Ec,m,Avg = 7812 Mpa PASS DN400 JP Test 2<br />
No damage, leakage or weeping<br />
No damage, leakage or weeping<br />
No damage, leakage or weeping<br />
No damage, leakage or weeping<br />
No signs <strong>of</strong><br />
damage to<br />
component<br />
s or change<br />
in pressure<br />
greater<br />
than<br />
0.08bar/h<br />
Withstand<br />
without<br />
leakage an<br />
internal<br />
pressure <strong>of</strong><br />
1.5 x PN for<br />
15mins<br />
No signs <strong>of</strong><br />
damage to<br />
component<br />
s nor leak<br />
No signs <strong>of</strong><br />
damage to<br />
component<br />
s nor leak<br />
DN400<br />
PN1<br />
DN400<br />
PN1<br />
DN400<br />
PN1<br />
DN400<br />
PN1<br />
JP Test 1<br />
JP Test 1<br />
JP Test 1<br />
JP Test 1