Jog mode<br />
CD06<br />
0 : Normal 1 : Jog Mode<br />
1. Set jogging operation from key panel & .<br />
2. LED blinking in JOG mode.<br />
Note : Refer to CD12 & CD42 for using jog mode by terminal control.<br />
Frequency meter<br />
correspond<br />
CD07<br />
The specification of the output<br />
meter is 10V(i.e. 1mA) full scale<br />
rating.<br />
Set by CD07 the value will be<br />
correspond to maximum<br />
correspond of MET terminal<br />
output meter.<br />
CW or CCW or<br />
CW/CCW<br />
CD08<br />
Setting Range 0 or 1<br />
Default value 0<br />
Setting Range 30.0 ~ 1200HZ<br />
60HZ region 120.0HZ<br />
50HZ region 100.0HZ<br />
Output<br />
(meter)<br />
10V<br />
Changeable<br />
30.00 1200HZ(F)<br />
Setting Range 0 ~ 2<br />
Default value 0<br />
0 : CW/CCW operation<br />
1 : CW only<br />
2 : CCW only<br />
If inadequate operation, the “OPE2“ warning message will be<br />
indicated.<br />