CONCENTO PLUS<br />

<strong>Data</strong> <strong>Sheet</strong><br />

<strong>Catalogue</strong><br />

Sicherheit nach DIN VDE 0834 Teil 1 und 2<br />

COMMUNICATION IN PERFECTION<br />

For nursing homes and assisted living –<br />

Safety in accordance with DIN VDE 0834 Part 1 and 2


Product overview<br />

1. Room terminals ................................................ 1<br />

19 0700 20 Terminal SD6 P .............................................. 2<br />

19 0700 40 Terminal S4 P ............................................... 4<br />

19 0700 70 Terminal S4 B ............................................... 6<br />

19 0700 80 Display module .............................................. 8<br />

19 0701 00 Call / presence combination bus (RAB) .......................... 10<br />

2. Room lamps, corridor displays ................................... 12<br />

77 0180 10 Room lamp universal, 3 sections ............................... 13<br />

77 0181 10 Room lamp universal, 3 sections, with doorplate .................. 14<br />

77 0185 10 Room lamp universal, 3 sections, glass decor .................... 15<br />

Z 00 8203 x2 Room signal plate, 2 sections .................................. 16<br />

Z 00 8203 x3 Room signal plate, 3 sections .................................. 17<br />

Z 00 8203 02 Apartment signal plate, 2 sections .............................. 18<br />

Z 00 8203 03 Apartment signal plate, 3 sections .............................. 19<br />

19 078x 08 Corridor display, 8-digit ........................................ 20<br />

19 078x 16 Corridor display, 16-digit ....................................... 21<br />

3. Switches .................................................... 22<br />

19 0707 20x Pull cord switch .............................................. 23<br />

19 0708 00 Call switch .................................................. 24<br />

19 0708 50 Call & cancel switch/WC ....................................... 25<br />

19 0709 00 Cancel switch/WC ............................................ 26<br />

19 0707 50x Pneumatic switch ............................................. 27<br />

4. Call switches with connection socket .............................. 28<br />

19 0704 00 Call switch with connection socket .............................. 29<br />

19 0704 20 Call switch with 2 connection sockets ........................... 30<br />

5. Plug-in call devices for connecting to connection sockets ............ 31<br />

19 0790 0x Pear push switches ........................................... 32<br />

19 0790 3x Pear push switches ........................................... 33<br />

Z 00 8201 10 Large-surface pneumatic switch ................................ 34<br />

Z 00 8201 20 Sound detector ............................................... 35<br />

Z 00 8201 30 1-channel respiratory dual sensor system ........................ 36<br />

Z 00 8002 04 Sensor mat CONCENTO ......................................<br />

37<br />

TUNSTALL <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes


6. Wireless call devices ........................................... 38<br />

Z 00 8202 00 Radio receiver 869.2125 MHz .................................. 39<br />

Z 00 8202 40 Handheld transmitter .......................................... 40<br />

Z 00 8202 10 Large-surface radio pneumatic switch ........................... 41<br />

Z 00 8202 50 Radio call switch ............................................. 42<br />

7. Wired call devices .............................................. 43<br />

Z 00 8002 00 Sensor mat with free cable ends ................................ 44<br />

19 0708 80 Smoke detector 24 V DC ...................................... 45<br />

8. Software .................................................... 46<br />

19 0803 00 ConLogPLUS Management Software ............................. 47<br />

19 0803 05 ConLogPLUS Management Software Client ....................... 49<br />

19 8000 10 Remote maintenance module for ConLogPLUS .................... 50<br />

9. System control ................................................. 49<br />

19 0800 84 Fire alarm Interface ........................................... 50<br />

19 0700 10 Group electronic (GE) ......................................... 51<br />

19 0700 00 Management interface ........................................ 53<br />

10. Power supply units ............................................ 56<br />

77 3400 00 Power supply unit UPS ........................................ 57<br />

77 3401 00 Power supply unit ............................................ 58<br />

77 3400 10 Power supply unit UPS 60 ..................................... 59<br />

77 3450 00 Battery set for UPS 60 ........................................ 60<br />

19 2103 02 Power supply unit 5A ......................................... 61<br />

11. Appendix: Accessories ......................................... 62<br />

19 0700 90 Mounting kit for terminal or GE ................................. 63<br />

19 1421 10 Pull cord kit for terminal ....................................... 63<br />

19 0800 92 Surface mounting frame for mounting kit ......................... 63<br />

19 0790 04 Self-releasing adapter for pear push switch ....................... 64<br />

19 0790 06 Extension cable for pear push switch, 5 m ....................... 64<br />

70 0361 00 Equipment and cable clamp .................................... 64<br />

19 9201 00 Central plate for 2 buttons ..................................... 65<br />

19 9201 04 Central plate for 1 button & 1 connection socket .................. 65<br />

19 9201 06 Central plate for 1 button ...................................... 65<br />

19 9201 08 Central plate for 1 button & 2 connection sockets ................. 65<br />

19 9200 06 Frame Jung AS 500 .......................................... 66<br />

19 9200 03 Frame Gira Standard 55 .......................................<br />

66<br />

TUNSTALL <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes


19 9200 07 Frame Gira Standard 55 glossy ................................. 66<br />

19 9200 04 Frame Merten System M-SMART ............................... 66<br />

19 9200 05 Frame Berker S.1 ............................................ 66<br />

19 8000 00 Personal Computer, German ................................... 67<br />

19 8001 00 Personal Computer, English ................................... 67<br />

19 0800 14 Null-modem cable ............................................ 67<br />

19 0800 15 Serial extension cable ......................................... 67<br />

19 0800 22 DCF77 Radio clock module for PC .............................. 67<br />

19 1990 12 Interface converter RS232 to RS485 ............................ 68<br />

19 1990 55 Sub-D adapter cable .......................................... 68<br />

70 0890 97 Overvoltage protection circuit .................................. 68<br />

11 5350 00 Telephone interface relay ...................................... 68<br />

77 0189 00 Doorplate universal ........................................... 69<br />

Z 00 8203 10 Room plate .................................................. 69<br />

Z 00 8203 20 Room plate with backlighting ................................... 69<br />

Z 00 8203 00 Apartment plate .............................................. 69<br />

70 0807 07 Connector, 7-pole ............................................ 71<br />

19 0702 82 Diagnostic connection cable ................................... 71<br />

17 0100 00 Back box solid wall, 1-gang .................................... 71<br />

17 0410 00 Back box solid wall, 2-gang .................................... 71<br />

17 5100 00 Back box partition wall, 1-gang ................................. 71<br />

17 5400 00 Back box partition wall, 2-gang ................................. 71<br />

12. Services ................................................... 72<br />

19 0000 63 Initial start-up assistance / commissioning support ................ 73<br />

19 0000 64 System introduction on-site .................................... 73<br />

19 0000 70 Preparation of a project specific database (per 10 rooms) ..........<br />

73<br />

TUNSTALL <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes


1. Room terminals<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 1


Terminal SD6 P<br />

19 0700 20 - Page 1 -<br />

General description<br />

Communication terminal with display, incorporat‐<br />

ing duplex speech system with all operating ele‐<br />

ments necessary for communication between pa‐<br />

tients or residents and staff.<br />

The terminal controls and monitors all room func‐<br />

tions in accordance with the German standard DIN<br />

VDE 0834. It is connected directly to the ward bus.<br />

The room components (room lamp and switches)<br />

are connected to the terminal.<br />

If the ward bus fails, the terminal continues working<br />

independently for the room. This provides max‐<br />

imum operational reliability.<br />

Specification<br />

Red call button with reassurance light and<br />

integrated location light<br />

Green presence button 1 with reminder light<br />

Yellow presence button 2 with reminder light<br />

Grey answer button with reminder light<br />

Grey remote cancel button (for calls that can<br />

be remotely cancelled after speech connection)<br />

with reminder light<br />

Grey universal button, freely programmable,<br />

preferably used as WC cancel button with<br />

reminder light<br />

All indicator lights use long lasting low-energy<br />

LEDs<br />

Simple operation thanks to clear symbols on all<br />

buttons<br />

2-line backlit display, 8-digit.<br />

Context-dependent display, e.g.: Call type,<br />

group and room number or up to 25-digit free<br />

text, number of further calls in the background,<br />

time and system messages<br />

Operating mode setting via display menu:<br />

- Patient's / resident's room<br />

- Staff room (incl. announcement function)<br />

- Staff room with function as main console<br />

(incl. announcement function and manual<br />

timezone change)<br />

High-quality voice communication<br />

Free function assignment of all inputs (7)<br />

Up to 4 room components can be connected in<br />

parallel per input<br />

Retrofittable pull cord (pull cord kit for terminal<br />

must be ordered separately)<br />

Service interface<br />

Automatic registration of the connected room<br />

components<br />

3 outputs 24 V / 100 mA for room lamp<br />

All inputs and outputs with short circuit,<br />

overload and reverse polarity protection<br />

Test function for testing the internally and<br />

externally connected illuminants<br />

Visual and audible indication of forwarded calls<br />

with presence activated. Tone depending on<br />

call type.<br />

Display of ”own” calls with suppression of the<br />

audible call forwarding.<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 2


Terminal SD6 P<br />

19 0700 20 - Page 2 -<br />

Service interface.<br />

Terminal can be programmed and configured<br />

during operation<br />

Compatible with existing Concento systems<br />

(agreement and inspection by manufacturer<br />

required)<br />

Technical data<br />

Dimensions incl.<br />

mounting plate (HxWxD): 190 x 102 x 50 mm<br />

Weight: approx. 330 g<br />

Housing material: ABS<br />

Colour: alpine white,<br />

similar to RAL 9010<br />

Power supply: 18 – 26 V DC<br />

Standby current<br />

consumption: approx. 90 mA<br />

at 24 V DC<br />

Order number Product name Note<br />

19 0700 20 Terminal SD6 P<br />

Necessary accessories, order separately:<br />

19 0700 90 Mounting kit for Terminal or GE see Appendix ”Accessories”<br />

17 0410 00 Back box solid wall, 2-gang see Appendix ”Accessories”<br />

17 5400 00 Back box partition wall, 2-gang see Appendix ”Accessories”<br />

Optional accessories, order if required:<br />

19 0800 92 Surface mounting frame for mounting kit see Appendix ”Accessories”<br />

19 1421 10 Pull cord kit for terminal see Appendix ”Accessories”<br />

Spare parts, order if required:<br />

19 9100 04 Connector, 4-pole<br />

19 9100 10 Connector, 10-pole<br />

19 9100 12 Connector, 12-pole<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 3


Terminal S4 P<br />

19 0700 40 - Page 1 -<br />

General description<br />

Communication terminal incorporating duplex<br />

speech system with all operating elements ne‐<br />

cessary for communication between patients or<br />

residents and staff.<br />

The terminal controls and monitors all room func‐<br />

tions in accordance with the German standard DIN<br />

VDE 0834. It is connected directly to the ward bus.<br />

The room components (room lamp and switches)<br />

are connected to the terminal.<br />

If the ward bus fails, the terminal continues working<br />

independently for the room. This provides max‐<br />

imum operational reliability.<br />

Specification<br />

Red call button with reassurance light and<br />

integrated location light<br />

Green presence button with reminder light<br />

Grey answer button with reminder light<br />

Grey remote cancel button (for calls that can<br />

be remotely cancelled after speech connection)<br />

with reminder light<br />

All indicator lights use long lasting low-energy<br />

LEDs<br />

Simple operation thanks to clear symbols on all<br />

buttons<br />

High-quality voice communication<br />

Free function assignment of all existing inputs<br />

(7) via external service module<br />

Up to 4 room components can be connected in<br />

parallel per input<br />

Retrofittable pull cord (pull cord kit for terminal<br />

must be ordered separately)<br />

Automatic registration of the connected room<br />

components<br />

3 outputs 24 V / 100 mA for room lamp<br />

All inputs and outputs with short circuit,<br />

overload and reverse polarity protection<br />

Test function for testing the internally and<br />

externally connected illuminants<br />

Audible indication of forwarded calls with<br />

presence activated, tone depending on call<br />

type<br />

Service interface<br />

Terminal programmable during operation<br />

Compatible with existing Concento systems<br />

(agreement and inspection by manufacturer<br />

required)<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 4


Terminal S4 P<br />

19 0700 40 - Page 2 -<br />

Technical data<br />

Dimensions incl.<br />

mounting plate (HxWxD): 190 x 102 x 50 mm<br />

Weight: approx. 305 g<br />

Housing material: ABS<br />

Colour: alpine white,<br />

similar to RAL 9010<br />

Power supply: 18 – 26 V DC<br />

Standby current<br />

consumption: approx. 80 mA<br />

at 24 V DC<br />

Order number Product name Note<br />

19 0700 40 Terminal S4 P<br />

Necessary accessories, order separately:<br />

19 0700 90 Mounting kit for Terminal or GE see Appendix ”Accessories”<br />

17 0410 00 Back box solid wall, 2-gang see Appendix ”Accessories”<br />

17 5400 00 Back box partition wall, 2-gang see Appendix ”Accessories”<br />

Optional accessories, order if required:<br />

19 0800 92 Surface mounting frame for mounting kit see Appendix ”Accessories”<br />

19 1421 10 Pull cord kit for terminal see Appendix ”Accessories”<br />

Spare parts, order if required:<br />

19 9100 04 Connector, 4-pole<br />

19 9100 10 Connector, 10-pole<br />

19 9100 12 Connector, 12-pole<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 5


Terminal S4 B<br />

19 0700 70 - Page 1 -<br />

General description<br />

Communication terminal incorporating duplex<br />

speech system with all operating elements ne‐<br />

cessary for communication between patients or<br />

residents and staff. Integrated inactivity alarm<br />

function for use in assisted living.<br />

The terminal controls and monitors all room func‐<br />

tions in accordance with the German standard DIN<br />

VDE 0834. It is connected directly to the ward bus.<br />

The room components (room lamp and switches)<br />

are connected to the terminal.<br />

If the ward bus fails, the terminal continues working<br />

independently for the room. This provides max‐<br />

imum operational reliability.<br />

Specification<br />

Red call button with reassurance light and<br />

integrated location light<br />

Green presence button with reminder light<br />

Grey day button / answer button with reminder<br />

light<br />

Grey away button / remote cancel button (for<br />

calls that can be remotely cancelled after<br />

speech connection) with reminder light<br />

All indicator lights use long lasting low-energy<br />

LEDs<br />

Simple operation thanks to clear symbols on all<br />

buttons<br />

Inactivity alarm function via 24-hour timer with<br />

trigger signal via an input or manually via day<br />

button<br />

”Resident away“ function with logging and<br />

status display.<br />

High-quality voice communication<br />

Free function assignment of all existing inputs<br />

(7) via external service module<br />

Up to 4 room components can be connected in<br />

parallel per input<br />

Retrofittable pull cord (pull cord kit for terminal<br />

must be ordered separately)<br />

Automatic registration of the connected room<br />

components<br />

Test function for testing the internally and<br />

externally connected illuminants<br />

3 outputs 24 V / 100 mA for room lamp<br />

All inputs and outputs with short circuit,<br />

overload and reverse polarity protection<br />

Audible indication of forwarded calls with<br />

Presence activated, tone depending on call<br />

type<br />

Service interface<br />

Terminal programmable during operation<br />

Compatible with existing Concento systems<br />

(agreement and inspection by manufacturer<br />

required)<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 6


Terminal S4 B<br />

19 0700 70 - Page 2 -<br />

Technical data<br />

Dimensions incl.<br />

mounting plate (HxWxD): 190 x 102 x 50 mm<br />

Weight: approx. 305 g<br />

Housing material: ABS<br />

Colour: alpine white,<br />

similar to RAL 9010<br />

Power supply: 18 – 26 V DC<br />

Standby current<br />

consumption: approx. 80 mA<br />

at 24 V DC<br />

Order number Product name Note<br />

19 0700 70 Terminal S4 B<br />

Necessary accessories, order separately:<br />

19 0700 90 Mounting kit for Terminal or GE see Appendix ”Accessories”<br />

17 0410 00 Back box solid wall, 2-gang see Appendix ”Accessories”<br />

17 5400 00 Back box partition wall, 2-gang see Appendix ”Accessories”<br />

Optional accessories, order if required:<br />

19 0800 92 Surface mounting frame for mounting kit see Appendix ”Accessories”<br />

19 1421 10 Pull cord kit for terminal see Appendix ”Accessories”<br />

Spare parts, order if required:<br />

19 9100 04 Connector, 4-pole<br />

19 9100 10 Connector, 10-pole<br />

19 9100 12 Connector, 12-pole<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 7


Display module<br />

19 0700 80 - Page 1 -<br />

General description<br />

Module for operation by the staff with presence but‐<br />

ton and call switch, plus display and buzzer for indi‐<br />

cating forwarded calls.<br />

The display module controls and monitors all room<br />

functions in accordance with the German standard<br />

DIN VDE 0834. It is connected directly to the ward<br />

bus. The room components (room lamp and<br />

switches) are connected to the terminal.<br />

If the ward bus fails, the display module continues<br />

working independently for the room. This provides<br />

maximum operational reliability.<br />

Made primarily for wall installation on 1-gang back<br />

box.<br />

Specification<br />

Red call button with reassurance light and<br />

integrated location light<br />

Green presence button with reminder light<br />

All indicator lights use long lasting low-energy<br />

LEDs<br />

Simple operation thanks to clear symbols on<br />

both buttons<br />

2-line backlit display, 8-digit.<br />

Context-dependent display, e.g.: Call type,<br />

group and room number or up to 25-digit free<br />

text, number of further calls in the background,<br />

time and system messages<br />

Visual and audible indication of forwarded calls<br />

with Presence activated, tone depending on<br />

call type<br />

Display of ”own” calls with suppression of the<br />

audible call forwarding<br />

Input for WC call switch (NO contact)<br />

Input for WC cancel switch (NO contact)<br />

Cancellation of WC calls can be set as an<br />

option via the presence button.<br />

3 inputs for beds (NO contact); can be<br />

changed in CONTENTO PLUS systems via<br />

display menu to: NO contact / NC contact, call<br />

type from more than 30 variants<br />

1 input in CONTENTO PLUS system for door<br />

call, in Concento system for room call; can be<br />

changed in CONTENTO PLUS via display menu<br />

to: NO contact / NC contact, call type from<br />

more than 30 variants<br />

Up to 4 monitored room devices can be<br />

connected per input<br />

3 outputs 24 V / 100 mA for room lamp<br />

All inputs and outputs with short circuit,<br />

overload and reverse polarity protection<br />

1 Connector, plug-in, 4-pole<br />

1 Connector, plug-in, 12-pole<br />

Compatible with existing Concento systems<br />

(agreement and inspection by manufacturer<br />

required)<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 8


Display module<br />

19 0700 80 - Page 2 -<br />

Technical data<br />

Dimensions (HxWxD): 190 x 102 x 50 mm<br />

Weight: approx. 180 g<br />

Housing material: ABS<br />

Colour: alpine white,<br />

similar to RAL 9010<br />

Power supply: 18 – 26 V DC<br />

Standby current<br />

consumption: approx. 7 mA at 24 V DC<br />

Order number Product name Note<br />

19 0700 80 Display module<br />

Necessary accessories, order separately:<br />

17 0100 00 Back box solid wall, 1-gang see Appendix ”Accessories”<br />

17 0410 00 Back box partition wall, 1-gang see Appendix ”Accessories”<br />

Spare parts, order if required:<br />

19 9100 04 Connector, 4-pole<br />

19 9100 12 Connector, 12-pole<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 9


Call/presence combination bus (RAB)<br />

19 0701 00 - Page 1 -<br />

General description<br />

Module for operation by the staff with presence but‐<br />

ton and call switch, plus buzzer or indicating for‐<br />

warded calls.<br />

The RAB controls and monitors all room functions<br />

in accordance with the German standard DIN VDE<br />

0834. It is connected directly to the ward bus. The<br />

room components (room lamp and switches) are<br />

connected to the terminal.<br />

If the ward bus fails, the RAB continues working in‐<br />

dependently for the room. This provides maximum<br />

operational reliability.<br />

Specification<br />

Red call button with reassurance light and<br />

integrated location light<br />

Green presence button with reminder light<br />

Simple operation thanks to clear symbols on<br />

both buttons<br />

Audible indication of forwarded calls with<br />

Presence activated, tone depending on call<br />

type<br />

Input for WC call switch (NO contact)<br />

Input for WC cancel switch (NO contact)<br />

3 inputs for beds (NO contact); can be<br />

changed in CONTENTOPLUS systems via<br />

external service module to: NO contact / NC<br />

contact, call type from more than 30 variants<br />

1 input in CONTENTOPLUS system for door<br />

call, in Concento system for room call; can be<br />

changed in CONTENTOPLUS via external<br />

service module to: NO contact / NC contact,<br />

call type from more than 30 variants<br />

Up to 4 monitored room devices can be<br />

connected per input<br />

3 outputs 24 V / 100 mA for room lamp<br />

All inputs and outputs with short circuit,<br />

overload and reverse polarity protection<br />

1 Connector, plug-in: 4-pole<br />

1 Connector, plug-in: 12-pole<br />

Compatible with existing Concento systems<br />

(agreement and inspection by manufacturer<br />

required)<br />

Without central plate, without frame<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 10


Call/presence combination bus (RAB)<br />

19 0701 00 - Page 2 -<br />

Technical data<br />

Dimensions (HxB): approx. 71 x 71 mm<br />

Weight (incl. central plate<br />

and frame): approx. 75 g<br />

Power supply: 18 – 26 V DC<br />

Standby current<br />

consumption: 7 mA at 24 V DC<br />

Order number Product name Note<br />

19 0701 00 Call/presence combination bus (RAB)<br />

Necessary accessories, order separately:<br />

19 9201 00 Central plate for 2 buttons<br />

19 9200 06 Frame Jung AS 500 see Appendix ”Accessories”<br />

19 9200 03 Frame Gira Standard 55 see Appendix ”Accessories”<br />

19 9200 07 Frame Gira Standard 55 glossy see Appendix ”Accessories”<br />

19 9200 04 Frame Merten System M-SMART see Appendix ”Accessories”<br />

19 9200 05 Frame Berker S.1 see Appendix ”Accessories”<br />

17 0100 00 Back box solid wall, 1-gang see Appendix ”Accessories”<br />

17 0410 00 Back box partition wall, 1-gang see Appendix ”Accessories”<br />

Spare parts, order if required:<br />

19 9100 04 Connector, 4-pole<br />

19 9100 12 Connector, 12-pole<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 11


2. Room lamps,<br />

corridor displays<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 12


Room lamp universal, 3 sections<br />

77 0180 10<br />

General description<br />

Signal lamp with 3 light sections for visual indica‐<br />

tion of all call types, staff presence and WC call as<br />

individual display.<br />

Suitable for installation on walls, in corridors or in<br />

rooms. Modular design with interchangeable dec‐<br />

orative frame.<br />

Other design versions on request.<br />

Compatible with system CCS, EccoLine L200,<br />

NewLine L200, Concento and CONCENTO PLUS .<br />

Specification<br />

3 Light sections<br />

Energy-saving, long-life LED illuminants<br />

Pluggable LED modules for easy change and<br />

for free selection of signalling colours<br />

Utility patent (DPMA)<br />

Design patent (DPMA)<br />

Easy plug & play installation<br />

Optical signalling<br />

LED red: Calls<br />

LED green: Presence<br />

LED white: WC call<br />

Technical data<br />

Dimensions (HxWxD): 110 x 150 x 40 mm<br />

Colour: Silver<br />

Housing material: Polycarbonate<br />

Power supply: 24 V DC<br />

Current consumption: 30 mA per light section<br />

Order number Product name Note<br />

77 0180 10 Room lamp universal, 3 sections<br />

Accessories required, order separately:<br />

70 0807 07 Connector, 7‐pole<br />

10 1701 00 Back box solid wall, 1‐gang see Appendix ”Accessories”<br />

10 1706 00 Back box partition wall, 1‐gang see Appendix ”Accessories”<br />

Optionally for rooms not connected to the nurse call system:<br />

70 0189 00 Doorplate universal see Appendix ”Accessories”<br />

Spare parts, order if required:<br />

77 0190 00 LED module, red<br />

77 0190 02 LED module, green<br />

77 0190 03 LED module, white<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 13


Room lamp universal, 3 sections,<br />

with doorplate<br />

77 0181 10<br />

General description<br />

Signal lamp with 3 light sections and doorplate for<br />

visual indication of all call types, staff presence and<br />

WC call as individual display. Doorplate as label<br />

field for the room name<br />

Suitable for installation on walls, in corridors or in<br />

rooms. Modular design.<br />

Compatible with system CCS, EccoLine L200,<br />

NewLine L200, Concento and CONCENTO PLUS .<br />

Specification<br />

3 Light sections<br />

Energy-saving, long-life LED illuminants<br />

Pluggable LED modules for easy change and<br />

for free selection of signalling colours<br />

Utility patent (DPMA)<br />

Design patent (DPMA)<br />

Easy plug & play installation<br />

Optical signalling<br />

LED red: Calls<br />

LED green: Presence<br />

LED white: WC call<br />

Technical data<br />

Dimensions (HxWxD): 190 x 150 x 40 mm<br />

Label field (HxW): approx. 70 x 92 mm<br />

Colour: Silver<br />

Housing material: Polycarbonate<br />

Power supply: 24 V DC<br />

Current consumption: 30 mA per light section<br />

Order number Product name Note<br />

77 0181 10 Room lamp universal, 3 sections, with doorplate<br />

Accessories required, order separately:<br />

70 0807 07 Connector, 7‐pole<br />

10 1701 00 Back box solid wall, 1‐gang see Appendix ”Accessories”<br />

10 1706 00 Back box partition wall, 1‐gang see Appendix ”Accessories”<br />

Optionally for rooms not connected to the nurse call system:<br />

70 0189 00 Doorplate universal see Appendix ”Accessories”<br />

70 0189 00 Doorplate universal see Appendix ”Accessories”<br />

Spare parts, order if required:<br />

77 0190 00 LED module, red<br />

77 0190 02 LED module, green<br />

77 0190 03 LED module, white<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 14


Room lamp universal, 3 sections, glass decor<br />

77 0185 10<br />

General description<br />

Signal lamp with 3 light sections for visual indica‐<br />

tion of all call types, staff presence and WC call as<br />

individual display.<br />

Suitable for installation on walls, in corridors or in<br />

rooms. Modular design with decorative glass<br />

frame.<br />

Further design versions on request.<br />

Compatible with system CCS, EccoLine L200,<br />

NewLine L200, Concento and CONCENTO PLUS .<br />

Specification<br />

3 Light sections<br />

Energy-saving, long-life LED illuminants<br />

Pluggable LED modules for easy change and<br />

for free selection of signalling colours<br />

Utility patent (DPMA)<br />

Design patent (DPMA)<br />

Easy plug & play installation<br />

Optical signalling<br />

LED red: Calls<br />

LED green: Presence<br />

LED white: WC call<br />

Technical data<br />

Dimensions (HxWxD): approx. 110 x 150 x 40 mm<br />

Housing material: Polycarbonate<br />

Power supply: 24 V DC<br />

Current consumption: 30 mA per light section<br />

Order number Product name Note<br />

77 0185 10 Room lamp universal, 3 sections, glass decor<br />

Accessories required, order separately:<br />

70 0807 07 Connector, 7‐pole<br />

10 1701 00 Back box solid wall, 1‐gang see Appendix ”Accessories”<br />

10 1706 00 Back box partition wall, 1‐gang see Appendix ”Accessories”<br />

Spare parts, order if required:<br />

77 0190 00 LED module, red<br />

77 0190 02 LED module, green<br />

77 0190 03 LED module, white<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 15


Room signal plate, 2 sections<br />

Z 00 8203 x2<br />

General description<br />

Elegant acrylic LED signal plate in a very attractive<br />

design with integrated LEDs in brilliant colours,<br />

fully visible through 180 degrees.<br />

2 light sections for visual indication of all call types<br />

and staff presence. Doorplate as label field for the<br />

room name.<br />

Only on room signal plate with backlighting: Back‐<br />

lighting as LEDs, power consumption: 30 mA.<br />

Attention: A separate power supply must be<br />

provided for the backlighting<br />

Suitable for installation on walls in corridors.<br />

Specification<br />

Energy-saving, long-life LED illuminants<br />

Convex shape<br />

Nameplate can be changed as desired<br />

Signalling<br />

LED red: Calls<br />

LED green: Presence<br />

Technical data<br />

Dimensions (HxWxD): 126 x 150 x 40 mm<br />

Weight: max. 250 g<br />

Power supply: 24 V DC<br />

Current consumption: 20 mA per light section<br />

Order number Product name Note<br />

Z 00 8203 12 Room signal plate, 2 sections<br />

Z 00 8203 22 Room signal plate with backlighting, 2 sections incl. white LEDs for backlighting<br />

Accessories required, order separately:<br />

10 1701 00 Back box solid wall, 1‐gang see Appendix ”Accessories”<br />

10 1706 00 Back box partition wall, 1‐gang see Appendix ”Accessories”<br />

Optionally for rooms not connected to the nurse call system:<br />

Z 00 8203 10 Room plate see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 16


Room signal plate, 3 sections<br />

Z 00 8203 x3<br />

General description<br />

Elegant acrylic LED signal plate in a very attractive<br />

design with integrated LEDs in brilliant colours,<br />

fully visible through 180 degrees.<br />

3 light sections for visual indication of all call types,<br />

staff presence and WC call as individual display.<br />

Doorplate as label field for the room name.<br />

Only on room signal plate with backlighting: Back‐<br />

lighting as LEDs, power consumption: 30 mA.<br />

Attention: A separate power supply must be<br />

provided for the backlighting<br />

Suitable for installation on walls in corridors.<br />

Specification<br />

Energy-saving, long-life LED illuminants<br />

Convex shape<br />

Nameplate can be changed as desired<br />

Signalling<br />

LED red: Calls<br />

LED green: Presence<br />

LED white: WC call<br />

Technical data<br />

Dimensions (HxWxD): 126 x 150 x 40 mm<br />

Weight: max. 250 g<br />

Power supply: 24 V DC<br />

Current consumption: 20 mA per light section<br />

Order number Product name Note<br />

Z 00 8203 13 Room signal plate, 3 sections<br />

Z 00 8203 23 Room signal plate with backlighting, 3 sections incl. white LEDs for backlighting<br />

Accessories required, order separately:<br />

10 1701 00 Back box solid wall, 1‐gang see Appendix ”Accessories”<br />

10 1706 00 Back box partition wall, 1‐gang see Appendix ”Accessories”<br />

Optionally for rooms not connected to the nurse call system:<br />

Z 00 8203 10 Room plate see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 17


Apartment signal plate, 2 sections<br />

Z 00 8203 02<br />

General description<br />

Elegant acrylic LED signal plate with integrated<br />

LEDs in brilliant colours, fully visible through 180<br />

degrees.<br />

2 light sections for visual indication of all call types<br />

and staff presence. Doorplate as label field for the<br />

apartment name.<br />

Suitable for installation on walls in corridors.<br />

Specification<br />

Energy-saving, long-life LED illuminants<br />

Convex shape<br />

Nameplate can be changed as desired<br />

Signalling<br />

LED red: Calls<br />

LED green: Presence<br />

Technical data<br />

Dimensions (HxWxD): 120 x 148 x 24 mm<br />

Weight: max. 220 g<br />

Power supply: 24 V DC<br />

Current consumption: 20 mA per light section<br />

Order number Product name Note<br />

Z 00 8203 02 Apartment signal plate, 2 sections<br />

Accessories required, order separately:<br />

10 1701 00 Back box solid wall, 1‐gang see Appendix ”Accessories”<br />

10 1706 00 Back box partition wall, 1‐gang see Appendix ”Accessories”<br />

Optionally for rooms / apartments not connected to the nurse call system:<br />

Z 00 8203 00 Apartment plate see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 18


Apartment signal plate, 3 sections<br />

Z 00 8203 03<br />

General description<br />

Elegant acrylic LED signal plate with integrated<br />

LEDs in brilliant colours, fully visible through 180<br />

degrees.<br />

3 light sections for visual indication of all call types,<br />

staff presence and WC call as individual display.<br />

Doorplate as label field for the apartment name.<br />

Suitable for installation on walls in corridors.<br />

Specification<br />

Energy-saving, long-life LED illuminants<br />

Convex shape<br />

Nameplate can be changed as desired<br />

Signalling<br />

LED red: Calls<br />

LED green: Presence<br />

LED white: WC call<br />

Technical data<br />

Dimensions (HxWxD): 120 x 148 x 24 mm<br />

Weight: max. 220 g<br />

Power supply: 24 V DC<br />

Current consumption: 20 mA per light section<br />

Order number Product name Note<br />

Z 00 8203 03 Apartment signal plate, 3 sections<br />

Accessories required, order separately:<br />

10 1701 00 Back box solid wall, 1‐gang see Appendix ”Accessories”<br />

10 1706 00 Back box partition wall, 1‐gang see Appendix ”Accessories”<br />

Optionally for rooms / apartments not connected to the nurse call system:<br />

Z 00 8203 00 Apartment plate see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 19


Corridor display, 8-digit<br />

19 078x 08<br />

General description<br />

Display for the alphanumeric displaying of calls and<br />

general system information.<br />

Intended for installation in corridors or staff rooms.<br />

Direct connection to the ward bus.<br />

Specification<br />

Display of call type and room number<br />

8-digit text display, text height 50 mm<br />

Light colour: Red<br />

Extra-bright Osram quality LEDs with ambient<br />

light-dependent light intensity, 2 brightness<br />

levels<br />

Serial RS485 interface with 19200 Baud<br />

Cable infeed from above<br />

Connecting cable 4-pole, length: approx. 1.2 m<br />

Preset address can be changed via DIP switch<br />

Protection class IP43<br />

Reverse polarity protection<br />

Overvoltage protection<br />

Single-sided version:<br />

Keyholes (distance: 46 cm) for wall mounting<br />

Double-sided version:<br />

Incl. ceiling suspension, 30 cm long<br />

Technical data<br />

Dimensions (HxWxD): 125 x 504 x 43 mm<br />

Weight: approx. 1 kg<br />

Housing material: Aluminium, lacquered<br />

Colour: RAL 9010 pure white<br />

Power supply:<br />

Current consumption, call:<br />

24 V DC<br />

- single-sided version: 270 mA<br />

- double-sided version: 530 mA<br />

Order number Product name Note<br />

19 0781 08 Corridor display, 8-digit Single-sided version<br />

19 0782 08 Corridor display, 8-digit, double-sided Double-sided version<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 20


Corridor display, 16-digit<br />

19 078x 16<br />

Similar to illustrated example<br />

General description<br />

Display for the alphanumeric displaying of calls and<br />

general system information.<br />

Intended for installation in corridors or staff rooms.<br />

Direct connection to the ward bus.<br />

Specification<br />

Display of call type and room number<br />

16-digit text display, text height 50 mm<br />

Light colour: Red<br />

Extra-bright Osram quality LEDs with ambient<br />

light-dependent light intensity, 2 brightness<br />

levels<br />

Serial RS485 interface with 19200 Baud<br />

Cable infeed from above<br />

Connecting cable 4-pole, length: approx. 1.2 m<br />

Preset address can be changed via DIP switch<br />

Protection class IP43<br />

Reverse polarity protection<br />

Overvoltage protection<br />

Single-sided version:<br />

Keyholes for wall mounting<br />

Double-sided version:<br />

Incl. ceiling suspension, 30 cm long<br />

Technical data<br />

Dimensions (HxWxD): 125 x 804 x 43 mm<br />

Weight: approx. 1,5 kg<br />

Housing material: Aluminium, lacquered<br />

Colour: RAL 9010 pure white<br />

Power supply:<br />

Current consumption, call:<br />

24 V DC<br />

- single-sided version: 530 mA<br />

- double-sided version: 1,060 mA<br />

Order number Product name Note<br />

19 0781 16 Corridor display, 16-digit Single-sided version<br />

19 0782 16 Corridor display, 16-digit, double-sided Double-sided version<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 21


3. Switches<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 22


Pull cord switch<br />

19 0707 20x<br />

General description<br />

Pull cord switch with reassurance light for raising<br />

calls. The reassurance light lights up as soon as a<br />

call is raised.<br />

Suitable for ceiling installation or wall installation.<br />

Specification<br />

Pull cord switch module with reassurance light<br />

as LED<br />

2 m red cord with red triangular handle<br />

Easy identification by symbol<br />

Sealing flange, degree of protection IP44<br />

Connection to terminal, display module,<br />

call/presence combination bus<br />

Terminating resistor 120 kOhm integrated<br />

Suitable for 1-gang back box<br />

Central plate 55 x 55 mm included<br />

Frame included<br />

Technical data<br />

Weight: approx. 90 g<br />

Material and colour: see switch range<br />

Standby current consumption: 0.05 mA<br />

Order number Product name Note<br />

19 0707 20J Pull cord switch incl. frame Jung AS 500 Frame Jung AS 500<br />

19 0707 20B Pull cord switch incl. frame Berker S. 1 Frame Berker S. 1<br />

19 0707 20G Pull cord switch incl. frame Gira Standard 55 matt Frame Gira Standard 55 matt<br />

19 0707 20GG Pull cord switch incl. frame Gira Standard 55 glossy Frame Gira Standard 55 glossy<br />

19 0707 20M Pull cord switch incl. frame Merten System M-SMART Frame Merten System M-SMART<br />

Necessary accessories, order separately:<br />

17 0100 00 Back box solid wall, 1-gang see Appendix ”Accessories”<br />

17 5100 00 Back box partition wall, 1-gang see Appendix ”Accessories”<br />

Spare parts reorder if required:<br />

19 1421 22 Pull cord for pull cord switch 2 m with triangle<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 23


Call switch<br />

19 0708 00<br />

General description<br />

Switch with a call button with reassurance light for<br />

raising calls. The reassurance light lights up as<br />

soon as a call is raised.<br />

Made primarily for wall installation.<br />

Specification<br />

Red call button with reassurance light and<br />

integrated location light as LED<br />

Easy identification by symbol<br />

Terminating resistor 120 kOhm integrated<br />

Connection to terminal, display module,<br />

call/presence combination bus<br />

Suitable for 1-gang back box<br />

Without central plate, without frame<br />

Technical data<br />

Weight: approx. 50 g<br />

Standby current consumption: 1 mA<br />

Order number Product name Note<br />

19 0708 00 Call switch<br />

Necessary accessories, order separately:<br />

19 9201 06 Central plate for 1 button<br />

19 9200 06 Frame Jung AS 500 see Appendix ”Accessories”<br />

19 9200 03 Frame Gira Standard 55 matt see Appendix ”Accessories”<br />

19 9200 07 Frame Gira Standard 55 glossy see Appendix ”Accessories”<br />

19 9200 04 Frame Merten System M-SMART see Appendix ”Accessories”<br />

19 9200 05 Frame Berker S.1 see Appendix ”Accessories”<br />

17 0100 00 Back box solid wall, 1-gang see Appendix ”Accessories”<br />

17 5100 00 Back box partition wall, 1-gang see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 24


Call & cancel switch/WC<br />

19 0708 50<br />

General description<br />

Switch with a call button and a cancel button for<br />

raising calls and for local cancellation in the WC<br />

area. The reassurance light in the call button lights<br />

up as soon as a call is raised.<br />

Made primarily for wall installation.<br />

Specification<br />

Red call button with reassurance light and<br />

integrated location light as LED<br />

Grey cancel button with reminder light as LED<br />

Easy identification by symbols<br />

Terminating resistor 120 kOhm integrated<br />

Connection to terminal, display module,<br />

call/presence combination bus<br />

Suitable for 1-gang back box<br />

Without central plate, without frame<br />

Technical data<br />

Weight: approx. 50 g<br />

Standby current consumption: 2 mA<br />

Order number Product name Note<br />

19 0708 50 Call & cancel switch/WC<br />

Necessary accessories, order separately:<br />

19 9201 00 Central plate for 2 buttons<br />

19 9200 06 Frame Jung AS 500 see Appendix ”Accessories”<br />

19 9200 03 Frame Gira Standard 55 matt see Appendix ”Accessories”<br />

19 9200 07 Frame Gira Standard 55 glossy see Appendix ”Accessories”<br />

19 9200 04 Frame Merten System M-SMART see Appendix ”Accessories”<br />

19 9200 05 Frame Berker S.1 see Appendix ”Accessories”<br />

17 0100 00 Back box solid wall, 1-gang see Appendix ”Accessories”<br />

17 5100 00 Back box partition wall, 1-gang see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 25


Cancel switch/WC<br />

19 0709 00<br />

General description<br />

Switch with a cancel button with reminder light for<br />

local cancellation of calls in the WC area.<br />

Preferably for the separate cancellation of calls<br />

from WC rooms en-suite to rooms.<br />

Made primarily for wall installation.<br />

Specification<br />

Grey cancel button with reminder light as LED<br />

Easy identification by symbol<br />

Terminating resistor 120 kOhm integrated<br />

Connection to terminal, display module,<br />

call/presence combination bus<br />

Suitable for 1-gang back box<br />

Without central plate, without frame<br />

Technical data<br />

Weight: approx. 50 g<br />

Standby current consumption: 1 mA<br />

Order number Product name Note<br />

19 0709 00 Cancel switch/WC<br />

Necessary accessories, order separately:<br />

19 9201 06 Central plate for 1 button<br />

19 9200 06 Frame Jung AS 500 see Appendix ”Accessories”<br />

19 9200 03 Frame Gira Standard 55 matt see Appendix ”Accessories”<br />

19 9200 07 Frame Gira Standard 55 glossy see Appendix ”Accessories”<br />

19 9200 04 Frame Merten System M-SMART see Appendix ”Accessories”<br />

19 9200 05 Frame Berker S.1 see Appendix ”Accessories”<br />

17 0100 00 Back box solid wall, 1-gang see Appendix ”Accessories”<br />

17 5100 00 Back box partition wall, 1-gang see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 26


Pneumatic switch<br />

19 0707 50x<br />

General description<br />

Pneumatic call switch with integrated reassurance<br />

light for raising calls via pneumatic actuation.<br />

The reassurance light lights up as soon as a call is<br />

raised.<br />

Made primarily for wall installation.<br />

Specification<br />

2 m air hose with red rubber ball<br />

Reassurance light as LED<br />

Hose is monitored for pulling off<br />

Terminating resistor 120 kOhm integrated<br />

Connection to terminal, display module,<br />

call/presence combination bus<br />

Suitable for 1-gang back box<br />

Central plate 55 x 55 mm included<br />

Frame included<br />

Technical data<br />

Weight: approx. 205 g<br />

Material and colour: see switch range<br />

Standby current consumption: 0.05 mA<br />

Order number Product name Note<br />

19 0707 50J Pneumatic switch incl. frame Jung AS 500 Frame Jung AS 500<br />

19 0707 50B Pneumatic switch incl. frame Berker S. 1 Frame Berker S. 1<br />

19 0707 50G Pneumatic switch incl. frame Gira Standard 55 matt Frame Gira Standard 55 matt<br />

19 0707 50GG Pneumatic switch incl. frame Gira Standard 55 glossy Frame Gira Standard 55 glossy<br />

19 0707 50M Pneumatic switch incl. frame Merten System M-SMART Frame Merten System M-SMART<br />

Necessary accessories, order separately:<br />

17 0100 00 Back box solid wall, 1-gang see Appendix ”Accessories”<br />

17 5100 00 Back box partition wall, 1-gang see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 27


4. Call switches<br />

with connection socket<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 28


Call switch with connection socket<br />

19 0704 00<br />

General description<br />

A call button with reassurance light for raising calls.<br />

The reassurance light lights up as soon as a call is<br />

raised.<br />

A socket for connecting a pear push switch or an‐<br />

other plug-in call device.<br />

Made primarily for wall installation.<br />

Specification<br />

Red call button with reassurance light and<br />

integrated location light as LED<br />

Easy identification by symbol<br />

1 connection socket with disconnection<br />

monitoring for pear push switch<br />

Connection to terminal, display module,<br />

call/presence combination bus<br />

Terminating resistor 120 kOhm integrated<br />

Suitable for 1-gang back box<br />

Without central plate, without frame<br />

Technical data<br />

Weight: approx. 55 g<br />

Standby current consumption: 18.48 mA<br />

Bestell‐Nummer Product name Note<br />

19 0704 00 Call switch with connection socket<br />

Necessary accessories, order separately:<br />

19 9201 04 Central plate for 1 button & 1 connection socket<br />

19 9200 06 Frame Jung AS 500 see Appendix ”Accessories”<br />

19 9200 03 Frame Gira Standard 55 matt see Appendix ”Accessories”<br />

19 9200 07 Frame Gira Standard 55 glossy see Appendix ”Accessories”<br />

19 9200 04 Frame Merten System M-SMART see Appendix ”Accessories”<br />

19 9200 05 Frame Berker S.1 see Appendix ”Accessories”<br />

19 0790 02 Pear push switch incl. call and light switch, 3 m see separate data sheet<br />

19 0790 00 Pear push switch incl.call switch, 3 m see separate data sheet<br />

19 0790 32 Pear push switch incl. call and light switch, 3 m see separate data sheet<br />

19 0790 30 Pear push switch incl. 2 call switches, 3 m see separate data sheet<br />

17 0100 00 Back box solid wall, 1-gang see Appendix ”Accessories”<br />

17 5100 00 Back box partition wall, 1-gang see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 29


Call switch with 2 connection sockets<br />

19 0704 20<br />

General description<br />

A call button with reassurance light for raising calls.<br />

The reassurance light lights up as soon as a call is<br />

raised.<br />

Two identical sockets for connecting pear push<br />

switches and/or other plug-in call devices.<br />

Made primarily for wall installation.<br />

Specification<br />

Red call button with reassurance light and<br />

integrated location light as LED<br />

Easy identification by symbol<br />

2 connection sockets with disconnection<br />

monitoring for pear push switches<br />

Connection to terminal, display module,<br />

call/presence combination bus<br />

Terminating resistor 120 kOhm integrated<br />

Suitable for 1-gang back box<br />

Without central plate, without frame<br />

Technical data<br />

Weight: approx. 55 g<br />

Standby current consumption: 18.48 mA<br />

Bestell‐Nummer Product name Note<br />

19 0704 20 Call switch with 2 connection sockets<br />

Necessary accessories, order separately:<br />

19 9201 08 Central plate for 1 button & 2 connection sockets<br />

19 9200 06 Frame Jung AS 500 see Appendix ”Accessories”<br />

19 9200 03 Frame Gira Standard 55 matt see Appendix ”Accessories”<br />

19 9200 07 Frame Gira Standard 55 glossy see Appendix ”Accessories”<br />

19 9200 04 Frame Merten System M-SMART see Appendix ”Accessories”<br />

19 9200 05 Frame Berker S.1 see Appendix ”Accessories”<br />

19 0790 02 Pear push switch incl. call and light switch, 3 m see separate data sheet<br />

19 0790 00 Pear push switch incl.call switch, 3 m see separate data sheet<br />

19 0790 32 Pear push switch incl. call and light switch, 3 m see separate data sheet<br />

19 0790 30 Pear push switch incl. 2 call switches, 3 m see separate data sheet<br />

17 0100 00 Back box solid wall, 1-gang see Appendix ”Accessories”<br />

17 5100 00 Back box partition wall, 1-gang see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 30


5. Plug-in call devices for<br />

connecting to<br />

connection socket<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 31


Pear push switch<br />

19 0790 0x<br />

Pear push switch incl. call and light switch<br />

Pear push switch incl. call switch<br />

General description<br />

Pear push switch incl. call and light switch: Waterprotected<br />

call and light switch for raising calls and<br />

for switching the reading light on and off.<br />

Pear push switch incl. call switch: Water-protected<br />

call switch for raising calls.<br />

Specification<br />

Red call button with reassurance light and<br />

integrated location light as LED<br />

3 tactile locating points on the call button<br />

Only pear push switch incl. call and light<br />

switch: Yellow light button<br />

Easy identification by symbols<br />

Disconnection monitoring<br />

Easy cleaning and disinfection thanks to<br />

water-protected, closed housing<br />

Protected against temporary immersion in<br />

water and dust-tight (IP67)<br />

3 m flexible connecting cable with 8-pole<br />

mini-DIN plug<br />

Technical data<br />

Dimensions (HxWxD): 70 x 35 x 10 mm<br />

Weight: approx. 150 g<br />

Material: ABS<br />

Colour: white, similar to RAL 9010<br />

Standby current<br />

consumption: 0.658 mA<br />

Order number Product name Note<br />

19 0790 02 Pear push switch incl. call and light switch, 3 m<br />

19 0790 00 Pear push switch incl.call switch, 3 m<br />

Optional accessories, order if required:<br />

19 0790 04 Self-releasing adapter pear push switch see Appendix ”Accessories”<br />

19 0790 06 Extension cable for pear push switch, 5 m see Appendix ”Accessories”<br />

70 0361 00 Equipment and cable clamp see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 32


Pear push switch<br />

19 0790 3x<br />

Pear push switch incl. call and light switch<br />

Pear push switch incl. 2 call switches<br />

General description<br />

Pear push switch incl. call and light switch: Mois‐<br />

ture-resistant call and light switch for raising calls<br />

and for switching the reading light on and off.<br />

Pear push switch incl. 2 call switches: Moistureresistant<br />

call switch for raising calls.<br />

Specification<br />

Pear push switch incl. call and light switch:<br />

- Red call button<br />

- Yellow light button<br />

Pear push switch incl. 2 call switches:<br />

- 2 red call buttons<br />

Reassurance light and integrated location light<br />

as LED<br />

Call button identified by a symbol<br />

Disconnection monitoring<br />

Easy cleaning and disinfection thanks to<br />

moisture-resistant, closed housing<br />

3 m flexible connecting cable with 8-pole<br />

mini-DIN plug<br />

Technical data<br />

Dimensions (HxB): 60 x 20 mm<br />

Weight: approx. 100 g<br />

Housing material: ABS<br />

Colour:<br />

Standby current<br />

RAL 9018, papyrus white<br />

consumption: 0.442 mA<br />

Order number Product name Note<br />

19 0790 32 Pear push switch incl. call and light switch, 3 m<br />

19 0790 30 Pear push switch incl. 2 call switches, 3 m<br />

Optional accessories, order if required:<br />

19 0790 04 Self-releasing adapter pear push switch see Appendix ”Accessories”<br />

19 0790 06 Extension cable for pear push switch, 5 m see Appendix ”Accessories”<br />

70 0361 00 Equipment and cable clamp see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 33


Large-surface pneumatic switch<br />

Z 00 8201 10<br />

Order number Product name Note<br />

Z 00 8201 10 Large-surface pneumatic switch<br />

General description<br />

Call switch for large-surface pneumatic activation.<br />

Only a very slight actuation force is required in or‐<br />

der to activate the switch. It is therefore very well<br />

suited when there are activation problems due to ill‐<br />

ness.<br />

Specification<br />

Red call button, round<br />

LED initiation indicator lights up red when the<br />

call button is pressed<br />

Disconnection monitoring<br />

Console mounting, also permanently installable<br />

Protected against splash water on all sides<br />

(IP44)<br />

Cable approx. 3 m long, with 8-pole mini-DIN<br />

plug for connecting to call switch with<br />

connection socket, order no. 19 0704 x0.<br />

Technical data<br />

Dimensions (HxØ): 45 x 110 mm<br />

Button diameter: 90 mm<br />

Weight: max. 125 g<br />

Operating voltage: 24 V DC / 35 mA<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 34


Sound detector<br />

Z 00 8201 20<br />

Order number Product name Note<br />

Z 00 8201 20 Sound detector<br />

General description<br />

Highly sensitive sound detector in desktop housing<br />

design, with intelligent speech level interpretation.<br />

Specification<br />

Integrated On/Off button<br />

Raising calls manually<br />

Variable sensitivity and response<br />

Simulation mode (for adjusting without initiating<br />

a call)<br />

Disconnection monitoring<br />

Operating, initiation and reassurance lamp<br />

Potential-free switching contact output<br />

Cable approx. 3 m long, with 8-pole mini-DIN<br />

plug for connecting to call switch with<br />

connection socket, order no. 19 0704 x0.<br />

Technical data<br />

Dimensions (HxØ): 50 x 110 mm<br />

Weight: approx. 150 g<br />

Colour: alpine white,<br />

similar to RAL 9010<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 35


1-channel respiratory dual sensor system<br />

Z 00 8201 30<br />

General description<br />

Flexible aid for raising calls via respiration. Highlysensitive<br />

sensor detects the slightest respiratory<br />

movements on the mouthpiece and triggers a cor‐<br />

responding function in the nurse call system.<br />

Thanks to easily interchangeable disposable parts<br />

such as the mouthpiece, antibacterial filter and<br />

hose, the system is well suited for use where pa‐<br />

tients change frequently. Simple disassembly of<br />

contaminated parts is performed without a tool and<br />

can be done by nursing staff. Very stable support‐<br />

ing arm with universal claw can be used almost<br />

everywhere without a tool: on round and square<br />

profiles (bed rails or stands) up to 6 cm thick, and<br />

many more. The electronic sensor module meets<br />

the highest standards in terms of quality and safety<br />

during use<br />

Specification<br />

1-channel sensor unit for raising calls by<br />

sucking or blowing, incl. cable approx. 3 m long<br />

with 8-pole mini-DIN plug for connecting to a<br />

call switch with connection socket, Order no.<br />

19 0704 x0<br />

Universal articulated arm, matt/chrome<br />

stainless steel. Extends max. 1 m, 4 hose<br />

clamps, flexible gooseneck, 2 articulated joints<br />

with clamping lever, with universal clamp for<br />

varied installation<br />

Disposable set for patient, comprised of:<br />

Mouthpiece, corrugated hose, bacteriological<br />

HEPA filter<br />

Disconnection monitoring<br />

Technical data<br />

Dimensions of the<br />

sensor unit (HxWxD): 180 x 105 x 65 mm<br />

Mounting: plug-in<br />

Operating voltage: 24 V DC / 100 mA<br />

Degree of protection: IP44<br />

Weight: approx. 1,950 g<br />

Order number Product name Note<br />

Z 00 8201 30 1-channel respiratory dual sensor system<br />

Consumables for reordering:<br />

Z 00 8200 31 Mouthpiece, corrugated hose, bacteriological HEPA filter Set contains 1 of each<br />

Z 00 8200 32 Mouthpiece Set of 5<br />

Z 00 8200 33 Corrugated hose 900 mm Set of 5<br />

Z 00 8200 34 Bacteriological HEPA filter Set of 5<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 36


Sensor mat CONCENTO<br />

Z 00 8002 04<br />

Order no. Product name Note<br />

Z 00 8002 04 Sensor mat CONCENTO<br />

General description<br />

Large-surface mat for raising calls by stepping on<br />

or pressing the mat.<br />

Suitable for use in hospitals, nursing homes and<br />

similar institutions.<br />

The mat is positioned e.g. by the bed. A call to the<br />

nurse call centre is raised when the patient gets out<br />

of bed or falls out of bed and onto the mat.<br />

Specification<br />

Fault monitoring<br />

Large sensor surface area<br />

Disconnection monitoring<br />

Waterproof<br />

PVC, easy to clean<br />

Cable approx. 3 m long, with 8-pole mini-DIN<br />

plug for connecting to call switch with<br />

connection socket, order no. 19 0704 x0.<br />

Technical data<br />

Colour: Ivory<br />

Material: PVC<br />

Power supply: 24 V DC<br />

Dimensions (W x D): 1200 x 500 mm<br />

Stepping surface thickness: 4 mm<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 37


6. Wireless call devices<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 38


Radio receiver 869.2125 MHz<br />

Z 00 8202 00<br />

General description<br />

Switching receiver on operating frequency<br />

869.2125 MHz (social alarm frequency) for receiv‐<br />

ing the signals from associated radio transmitters.<br />

Specification<br />

Integrated antenna<br />

8 radio transmitters programmable<br />

Master mode can be activated to receive any<br />

number of radio transmitters<br />

Intelligent battery monitoring of the associated<br />

radio transmitters (if present at the transmitter)<br />

Monitoring of the automatic daily test<br />

messages in accordance with EN 50134 (if<br />

present at the transmitter)<br />

Disconnection monitoring<br />

Operation monitoring in accordance EN 50134<br />

Protection Class IP20<br />

Radio range dependent on the spatial<br />

conditions, approx. 15 to 30 m<br />

Short cable with 8-pole mini-DIN plug for<br />

connecting to the call switch with connection<br />

socket, order no. 19 0704 x0.<br />

Technical data<br />

Dimensions (HxWxD): 130 x 40 x 24 mm<br />

Weight: approx. 70 g<br />

Operating voltage: 24 V DC<br />

Order number Product name Note<br />

Z 00 8202 00 Radio receiver 869.2125 MHz<br />

Optional accessories, order if required:<br />

Z 00 8202 20 Magnetic wall bracket see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 39


Handheld transmitter<br />

Z 00 8202 40<br />

General description<br />

Water-protected (IP66) clock-shaped handheld<br />

transmitter with stretch armband for carrying on the<br />

wrist.<br />

Specification<br />

Red call button, rubber-coated, diameter:<br />

19 mm<br />

LED initiation indicator lights up red when the<br />

call button is pressed<br />

Protected against powerful water jets (IP66)<br />

Automatic daily test message in accordance<br />

with EN 50135<br />

Intelligent battery monitoring with control signal<br />

on receiver<br />

Typical battery life: 3 years<br />

Radio frequency 869.2125 MHz<br />

Stretch wriststrap with clip buckle<br />

Technical data<br />

Dimensions (HxWxD): 46 x 43 x 15 mm<br />

Weight: approx. 25 g<br />

Power supply. 3.0 V button cell battery<br />

CR2032, replaceable<br />

Order number Product name Note<br />

Z 00 8202 40 Handheld transmitter<br />

Radio receiver required, order separately:<br />

Z 00 8202 00 Radio receiver 869.2125 MHz<br />

Stretch wriststraps for reordering:<br />

Z 00 8202 41 Stretch wriststrap Packaging unit: 10 wriststraps<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 40


Large-surface radio pneumatic switch<br />

Z 00 8202 10<br />

Order number Product name Note<br />

Z 00 8202 10 Large-surface radio pneumatic switch<br />

Radio receiver required, order separately:<br />

Z 00 8202 00 Radio receiver 869.2125 MHz<br />

General description<br />

Wireless switch for large-surface pneumatic initia‐<br />

tion of calls.<br />

Only a very slight actuation force is required in or‐<br />

der to activate the switch. It is therefore very well<br />

suited when there are activation problems due to ill‐<br />

ness.<br />

Used in conjunction with the radio receiver on the<br />

same frequency.<br />

Specification<br />

Red call button, round<br />

LED initiation indicator lights up red when the<br />

call button is pressed<br />

Protected against splash water on all sides<br />

(IP44)<br />

Intelligent battery monitoring with control signal<br />

on receiver<br />

Automatic daily test message in accordance<br />

with EN 50135<br />

Typical battery life: 3 years<br />

Radio frequency 869.2125 MHz<br />

Technical data<br />

Dimensions (HxB): 45 x 110 mm<br />

Button diameter: 90 mm<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 41


Radio call switch<br />

Z 00 8202 50<br />

Order number Product name Note<br />

Z 00 8202 50 Radio call switch<br />

Radio receiver required, order separately:<br />

Z 00 8202 00 Radio receiver 869.2125 MHz<br />

General description<br />

Water-protected (IP66) radio transmitter for direct<br />

wall mounting.<br />

Specification<br />

Red call button, rubber-coated, diameter:<br />

19 mm<br />

LED initiation indicator lights up red when the<br />

call button is pressed<br />

Protected against powerful water jets (IP66)<br />

Intelligent battery monitoring with control signal<br />

on receiver<br />

Automatic daily test message in accordance<br />

with EN 50135<br />

Typical battery life: 3 years<br />

Radio frequency 869.2125 MHz<br />

Wall mounting via screw mounting or<br />

double-sided adhesive tape<br />

Technical data<br />

Dimensions (DxT): 80 x 15 mm<br />

Weight: approx. 55 g<br />

Power supply. 3.0 V button cell battery<br />

CR2032, replaceable<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 42


7. Wired call devices<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 43


Sensor mat with free cable ends<br />

Z 00 8002 00<br />

Order no. Product name Note<br />

Z 00 8002 00 Sensor mat with free cable ends<br />

General description<br />

Large mat for raising calls by stepping on or press‐<br />

ing the mat.<br />

Suitable for use in hospitals, nursing homes, retire‐<br />

ment homes, assisted living and similar facilities,<br />

as well as in private accommodation.<br />

The mat is positioned e.g. by the bed. A call is<br />

raised when the patient gets out of bed or falls out<br />

of bed and onto the mat. The call is forwarded to the<br />

connected nurse call system or to the connected<br />

call device.<br />

Specification<br />

Large sensor surface area<br />

Protected against splash water<br />

PVC, easy to clean<br />

Connecting cable with free wire ends for<br />

connecting to any desired alarm system<br />

NO contact<br />

Technical data<br />

Colour: Ivory<br />

Material: PVC<br />

Power supply: 24 V DC<br />

Dimensions (W x D): 1.200 x 500 mm<br />

Stepping surface thickness: 4 mm<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 44


Smoke detector 24 V DC<br />

19 0708 80<br />

Order no. Product name Note<br />

19 0708 80 Smoke detector 24 V DC<br />

General description<br />

Optoelectronic smoke detector for the early detec‐<br />

tion of smoke.<br />

Specification<br />

Measure principle: IRED radiation / optical<br />

(scattering) / photo diode<br />

Response threshold in accordance with<br />

prEN ISO 12239<br />

Sensor fault signal 'Beep' + after approx. 22 s<br />

LED pulse<br />

Individual display: LED red<br />

Audible alarm approx. 85 dB (3 m)<br />

Approval VdS G 202061<br />

Monitored area 60 m2 Ceiling mounting, maximum 6 m height<br />

Degree of protection: IP 30<br />

Relay module with potential-free contact for<br />

forwarding the alarm<br />

Power supply circuit board 24 V DC<br />

Technical data<br />

Dimensions (HxD): 48 x 96 mm<br />

Weight: approx. 130 g<br />

Material: Polycarbonate<br />

Calibre<br />

Colour: white<br />

Standby current consumption: 10 A<br />

Current consumption, alarm: 35 mA<br />

Voltage supply: 24 V DC<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 45


8. Software<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 46


ConLog PLUS Management Software<br />

19 0803 00 - Page 1 -<br />

General description<br />

The purpose of the ConLogPLUS management soft‐<br />

ware is the central configuration and programming<br />

of nurse call systems, and the logging and evalua‐<br />

tion of all system events of these nurse call sys‐<br />

tems. It can also be used in Concento systems with<br />

ConLog II software.<br />

Basic properties of the software<br />

The PC with ConLogPLUS Management<br />

Software is connected to the management<br />

interface of the nurse call system<br />

Graphic user interface<br />

User interface can be adapted to the user's<br />

specific needs<br />

Easy to use due to intuitive operation<br />

Freely definable user management: Only the<br />

functions that the individual users groups (e.g.<br />

system administrators, service technicians)<br />

need for their work are available to them<br />

Project-based data administration<br />

Automatic daily back-up of the database with<br />

time setting<br />

Online back-up possible<br />

Network-capable: Can be used as a<br />

stand-alone solution or allows networking of<br />

several PCs to form a client/server structure<br />

Optionally 10 additional workstations (clients)<br />

can be set up - to be ordered separately<br />

Software in German and English. Additional<br />

languages on request.<br />

Remote diagnosis of the ConLog PLUS<br />

Management Software via ISDN FRITZ!Card<br />

and pcAnywhere software<br />

System configuration and programming<br />

Central configuration of the entire nurse call<br />

system<br />

Establishment of the logical structure of the<br />

nurse call system in wards, zones and shifts<br />

Entry of ward and room names<br />

Programming of the management interface, the<br />

group electronics and terminals with the<br />

project-specific settings via the bus system<br />

through the management interface<br />

Firmware updates of the management<br />

interface, the group electronics and terminals<br />

Administration of the system interfaces for<br />

radio paging and telephony<br />

Administration of call forwarding to Telecare<br />

Control Centres<br />

Call logging and reporting<br />

Logging all events of the nurse call system with<br />

date timestamp<br />

Recording the raising of calls, call type, call<br />

location, call answering, acknowledgement,<br />

cancellation<br />

Distinguishing between remote cancellation<br />

and cancellation at call location<br />

Active alarm stack, status messages, event<br />

display<br />

SQL database format<br />

Import of existing databases in Access format<br />

possible from ConLogll versions<br />

Simple and effective reporting<br />

Reports can be configured according to the<br />

parameters, e.g. according to call type, date,<br />

room number, floor<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 47


ConLog PLUS Management Software<br />

19 0803 00 - Page 2 -<br />

Order number Product name Note<br />

System requirements<br />

Operating system<br />

Microsoft ® Windows ® 7 (32 Bit, 64 Bit) or<br />

Microsoft ® Windows ® XP with SP3<br />

Minimum hardware requirement:<br />

CPU with 1 GHz<br />

4 GB RAM<br />

40 GB hard drive<br />

1 serial COM interface<br />

DVD drive<br />

17 inch monitor<br />

USB 2.0<br />

LAN<br />

For remote diagnosis:<br />

ISDN FRITZ!Card<br />

Software pcAnywhere installed<br />

19 0803 00 ConLog PLUS Management Software Server license<br />

Necessary accessories, order separately:<br />

19 0700 00 Management Interface see separate data sheet<br />

19 0800 15 Serial extension cable see Appendix ”Accessories”<br />

19 8000 00 Personal Computer, German see Appendix ”Accessories”<br />

19 8001 00 Personal Computer, English see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 48


ConLog PLUS Management Software Client<br />

19 0803 05<br />

General description<br />

The purpose of the ConLog PLUS management soft‐<br />

ware is the central configuration and programming<br />

of nurse call systems, and the logging and evalua‐<br />

tion of all system events of these nurse call sys‐<br />

tems. Up to 10 client workstations, order no.<br />

19 0803 05, can be operated in the network with<br />

one server workstation, order no. 19 0803 00.<br />

Basic properties of the software<br />

Graphic user interface<br />

User interface can be adapted to the user's<br />

specific needs<br />

Easy to use due to intuitive operation<br />

Freely definable user management: Only the<br />

functions that the individual users groups (e.g.<br />

system administrators, service technicians)<br />

need for their work are available to them<br />

Software in German and English. The user can<br />

enter additional languages.<br />

System configuration and programming<br />

Central configuration of the entire nurse call<br />

system<br />

Establishment of the logical structure of the<br />

nurse call system in wards, zones and shifts<br />

Entry of ward and room names<br />

Order number Product name Note<br />

Programming of the management interface, the<br />

group electronics and terminals with the<br />

project-specific settings via the bus system via<br />

management interface<br />

Firmware updates of the management<br />

interface, the group electronics and terminals<br />

Administration of the system interfaces for<br />

radio paging and telephony<br />

Administration of call forwarding to Telecare<br />

Control Centres<br />

Call logging and reporting<br />

Recording the raising of calls, call type, call<br />

location, call answering, acknowledgement,<br />

cancellation<br />

Distinguishing between remote cancellation<br />

and cancellation at call location<br />

Active alarm stack, status messages, event<br />

display<br />

Simple and effective reporting<br />

Reports can be configured according to the<br />

parameters, e.g. according to call type, date,<br />

room number, floor<br />

System requirements<br />

Operating system<br />

Microsoft ® Windows ® 7 (32 Bit, 64 Bit) or<br />

Microsoft ® Windows ® XP with SP3<br />

Minimum hardware requirement:<br />

CPU with 1 GHz<br />

4 GB RAM<br />

40 GB hard drive<br />

1 serial COM interface<br />

DVD drive<br />

17 inch monitor<br />

USB 2.0<br />

LAN<br />

19 0803 05 ConLog PLUS Management Software Client Client license<br />

Necessary accessories, order separately:<br />

19 8000 00 Personal Computer, German see Appendix ”Accessories”<br />

19 8001 00 Personal Computer, Englisch see Appendix ”Accessories”<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 49


Remote maintenance module for ConLog PLUS<br />

19 8000 10<br />

General description<br />

For remotely controlling the computer on which the<br />

ConLogPLUS Management Software is installed in<br />

order to diagnose faults, install updates or provide<br />

support in operation.<br />

A system technician logs onto the PC to do this.<br />

Third-party remote access is not possible.<br />

Order number Product name Note<br />

19 8000 10 Remote maintenance module for ConLog PLUS<br />

Necessary accessories, order separately:<br />

Performance features<br />

Efficient troubleshooting on remote systems<br />

File transfer in the background<br />

Supports 13 different authentication methods<br />

including LDAP, ADS, NDS, Novell Bindery, NT<br />

domains and RSA SecurID<br />

Input prompt, task manager, services and<br />

Regedit can be started directly from the user<br />

interface<br />

Fast remote connections due to compatibility<br />

with cable and DSL modems<br />

Reliable security functions protect against<br />

unauthorised access<br />

System requirements (not included)<br />

Operating system:<br />

Microsoft ® Windows ® 7 or<br />

Microsoft ® Windows ® XP<br />

Hardware:<br />

CPU with min. 500 MHz<br />

Min. 128 MB RAM<br />

Min. 35 MB free disc space<br />

1 serial COM drive<br />

CD-ROM drive<br />

Free PCI slot<br />

Local ISDN connection to the PC<br />

19 0700 00 Management Interface see separate data sheet<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 50


9. System control<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 51


Fire alarm interface<br />

19 0800 84<br />

Order number Product name Note<br />

19 0800 84 Fire alarm interface<br />

General description<br />

Fire alarm interface for connecting a fire alarm sys‐<br />

tem via ESPA protocol 4.4.4 to a Concento or<br />

<strong>CONCENTOPLUS</strong> system.<br />

Note: This system does not replace a fire alarm<br />

system alert in accordance with the German stan‐<br />

dard DIN VDE 0833.<br />

Specification<br />

Programming via the supplied software tool<br />

”BMA-IConfig”<br />

Status LED for group bus and voltage supply<br />

on the printed circuit board<br />

Coupling of alarms for display in the nurse call<br />

system depending on the system<br />

programming: Logical group and room number<br />

or free text<br />

Connection to the group bus<br />

RS232, interface to fire alarm system,<br />

preferably FAT 2002<br />

Technical data<br />

Dimensions (HxWxD): 190 x 116 x 63 mm<br />

Weight: 322 g<br />

Housing material: Plastic<br />

Power supply: 24 V DC<br />

Standby current<br />

consumption: 40 mA<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 52


Group electronic (GE)<br />

19 0700 10 - Page 1 -<br />

General description<br />

The group electronic (GE) is the control unit within<br />

the decentralised system structure of the<br />

<strong>CONCENTOPLUS</strong> system.<br />

The group electronic monitors and controls all of<br />

the data traffic, as well as the speech communica‐<br />

tion of all users connected to one ward bus. All<br />

group electronics are connected to each other via<br />

the group bus. The group bus is controlled by all<br />

connected group electronics according to the mas‐<br />

ter-slave principle.<br />

The group electronic is intended for wall mounting<br />

in floor distributors or installation rooms<br />

Compatible with existing Concento systems<br />

(agreement and inspection by manufacturer re‐<br />

quired).<br />

Specification<br />

Control of the ward bus<br />

Control of functions covering more than one<br />

ward such as group coupling, shift operation,<br />

speech connection covering more than one<br />

group, higher-order calls (e.g. alarm call)<br />

Master-slave principle on the group bus<br />

Display of the master-slave status<br />

Up to 40 users per ward bus<br />

Up to 40 users per group bus<br />

Up to 128 logical groups per system<br />

Fault display for the group electronic<br />

Fault display for the group bus<br />

Fault display for the ward bus<br />

Energy-efficient, durable LEDs<br />

Button for displaying the active messages<br />

(calls, presence, faults) on the ward bus<br />

2-line display, 8-digit, with backlighting for<br />

status display: Time, shift and number of<br />

messages in the system<br />

3 buttons for operating the display menu<br />

Output to the group lamp, 24 V / 300 mA<br />

Output to the fault lamp, 24 V / 300 mA<br />

Output to the fault signal relay (NO/NC),<br />

potential-free<br />

Input for mains power failure message<br />

(24 V DC), preferably in conjunction with power<br />

supply unit UPS, order no. 77 3400 00, or<br />

power supply unit UPS 60, order no.<br />

77 3400 10)<br />

All inputs and outputs with short circuit,<br />

overload and reverse polarity protection<br />

Stand-alone operation possible without group<br />

bus<br />

Group electronic can be programmed and<br />

configured during operation<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 53


Group electronic (GE)<br />

19 0700 10 - Page 2 -<br />

Technical data<br />

Dimensions incl.<br />

mounting plate (HxWxD): 190 x 102 x 50 mm<br />

Weight: approx. 295 g<br />

Housing material: ABS<br />

Colour: alpine white,<br />

similar to RAL 9010<br />

Standby current<br />

consumption: approx. 60 mA<br />

at 24 V DC<br />

Order number Product name Note<br />

19 0700 10 Group electronic (GE)<br />

Necessary accessories, order separately:<br />

19 0700 90 Mounting kit for terminal or GE see Appendix ”Accessories”<br />

10 1702 00 Back box solid wall, 2-gang see Appendix ”Accessories”<br />

10 1707 00 Back box partition wall, 2-gang see Appendix ”Accessories”<br />

Spare parts, order if required:<br />

19 9100 04 Connector, 4-pole<br />

19 9100 10 Connector, 10-pole<br />

19 9100 12 Connector, 12-pole<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 54


Management Interface<br />

19 0700 00<br />

General description<br />

Interface for transmitting call and system mes‐<br />

sages, speech phrases and connections for the<br />

speech communication via telephone systems. Ad‐<br />

ditional interfaces are available for system admin‐<br />

istration and for forwarding logging data.<br />

Compatible with existing Concento systems<br />

(agreement and inspection by manufacturer re‐<br />

quired).<br />

Performance features<br />

Convenient programming with<br />

ConLogPLUS Management Software<br />

Extensive configuration possibilities of the<br />

various interfaces and system parameters<br />

Call transfer to Telecare Control Centres<br />

(WILMA or PNC centres)<br />

Convenient speech phrases for call type and<br />

call location (ward and room number) and for<br />

operation<br />

Intuitive menu guidance for simple and safe<br />

operation<br />

Order number Product name Note<br />

19 0700 00 Management Interface<br />

Intelligent status displays: <strong>Data</strong> bus, ESPA<br />

4.4.4, telephone connection and ConLogPLUS connection<br />

Extensive information display: Date, time, IP<br />

address, ID number<br />

Interfaces<br />

RS232, interface to the light call server<br />

RS232, interface, ESPA 4.4.4 protocol<br />

RJ45, network connection up to 100 MBit/s<br />

RJ45, connection prepared for VoIP and<br />

ESPA-X protocol up to 100 MBit/s<br />

RJ11, telephone connection<br />

USB connection prepared for future<br />

applications<br />

Interface to the group bus or ward bus<br />

Fault signal output, potential-free (NO/NC)<br />

Bus connections and power supply connection<br />

with short circuit, overload and reverse polarity<br />

protection<br />

Equipment<br />

Console housing for wall mounting, with<br />

removable control unit and separate<br />

connection unit<br />

Membrane keyboard with 16 function keys<br />

Colour TFT display with 320 x 240 characters,<br />

3.5”, backlit<br />

SDHC memory card (4 GB) for data storage<br />

Real-time clock, lithium battery CR2032<br />

Wall mounting via 1-gang back box or cable<br />

duct<br />

Technical data<br />

Dimensions (HxWxD): 135 x 190 x 90 mm<br />

Weight: approx. 640 g<br />

Housing material: ABS<br />

Farbe: RAL 9002 grey white<br />

Power supply: 18 – 26 V DC<br />

Standby current<br />

consumption: 240 mA at 24 V DC<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 55


10. Power supply units<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 56


Power supply unit UPS<br />

77 3400 00<br />

General description<br />

Power supply unit for supplying the nurse call sys‐<br />

tem with safety extra-low voltage (SELV), com‐<br />

pliant with EN 60950. The number of rooms, that<br />

can be connected, is project specific. Integrated<br />

batteries for uninterruptable operation with a mini‐<br />

mum of 15 minutes backup power supply.<br />

Wide range input for international use.<br />

Short-circuit and overload protected.<br />

Control LEDs and contact outputs for transmission<br />

of status information: normal operation, battery<br />

operation, fault message.<br />

Closed housing in protection class I. Designed for<br />

wall mounting in rooms.<br />

Input<br />

Nominal input voltage: 115 - 230 V AC<br />

Voltage range: 90 - 264 V AC<br />

Input frequency: 50 - 60 Hz<br />

Input current: 4 A at 115 V AC<br />

2 A at 230 V AC<br />

Output<br />

Nominal output voltage: 24 V DC +/- 2%<br />

- at battery operation: typ. 26.5 - 19.5 V DC<br />

Output current: 12 A<br />

Output power: 288 W<br />

Battery capacity: 7 Ah<br />

Loading current: typ. 700 mA<br />

Back-up time: approx. 17 min at 80% load<br />

Approvals<br />

Safety: EN 60950, SELV<br />

EMC, CE certified: EN 55022 class B<br />

ENV 50204; EV 61000-3-2<br />

EN 61000-4-2, -3, -4, -5, -6, -8, -11<br />

Protection class: Class I<br />

Degree of protection: IP 20<br />

Connections<br />

Mains input: Direct mains connection<br />

via internal screw clamp<br />

Outputs: Pluggable via clamp<br />

General<br />

Ambient temperature: 0 ... +50 °C<br />

Storage temperature: -25 ... +60 °C<br />

MTBF: 100.000 hours<br />

(without batteries)<br />

Weight: 9 kg<br />

Dimensions (HxWxD): 244 x 325 x 178 mm<br />

Colour: RAL 7035 Light grey<br />

Order number Product name Notes<br />

77 3400 00 Power supply unit UPS<br />

Spare parts, order if required:<br />

00 0211 39 Connector for control and message outputs, 7-pole<br />

00 0211 40 Connector for mains connection, 3-pole<br />

00 0211 41 Connector for 24 V connection<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 57


Power supply unit<br />

77 3401 00<br />

General description<br />

Power supply unit for supplying the nurse call sys‐<br />

tem with safety extra-low voltage (SELV), com‐<br />

pliant with EN 60950. The number of rooms, that<br />

can be connected, is project specific.<br />

Wide range input for international use.<br />

Short-circuit and overload protected.<br />

Control LEDs and contact output for transmission<br />

of the active operation status.<br />

Closed housing in protection class I. Designed for<br />

wall mounting in rooms.<br />

Technical data<br />

Input<br />

Nominal input voltage: 115 - 230 V AC<br />

Voltage range: 90 - 264 V AC<br />

Input frequency: 50 - 60 Hz<br />

Input current: 4 A at 115 V AC<br />

2 A at 230 V AC<br />

Output<br />

Nominal output voltage: 24 V DC +/- 2%<br />

Output current: 12 A<br />

Output power: 288 W<br />

Approvals<br />

Safety: EN 60950, SELV<br />

EMC, CE certified: EN 55022 class B<br />

ENV 50204; EV 61000-3-2<br />

EN 61000-4-2, -3, -4, -5, -6, -8, -11<br />

Protection class: Class I<br />

Degree of protection: IP 20<br />

Connections<br />

Mains input: Direct mains connection<br />

via internal screw clamp<br />

Outputs: Pluggable via clamp<br />

General<br />

Ambient temperature: 0 ... +50 °C<br />

Storage temperature: -25 ... +60 °C<br />

MTBF: 100000 hours<br />

Weight: 2 kg<br />

Dimensions (HxWxD): 244 x 325 x 178 mm<br />

Colour: RAL 7035 Light grey<br />

Order number Product name Notes<br />

77 3401 00 Power supply unit<br />

00 0211 39 Connector for control and message outputs, 7-pole<br />

00 0211 40 Connector for mains connection, 3-pole<br />

00 0211 41 Connector for 24 V connection, 4-pole<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 58


Power supply unit UPS 60<br />

77 3400 10<br />

General description<br />

Power supply unit for supplying the nurse call sys‐<br />

tem with safety extra-low voltage (SELV), com‐<br />

pliant with EN 60950. The number of rooms, that<br />

can be connected, is project specific. Uninterrupt‐<br />

able operation in connection with battery set for<br />

UPS 60, order no. 77 3450 00, with approx. 1 hour<br />

backup power supply. Wide range input for interna‐<br />

tional use. Short-circuit and overload protected.<br />

Control LEDs and contact outputs for transmission<br />

of status information: normal operation, battery<br />

operation, fault message.<br />

Closed housing in protection class I. Designed for<br />

wall mounting in rooms, preferably above the bat‐<br />

tery set for UPS 60.<br />

Input<br />

Nominal input voltage: 115 - 230 V AC<br />

Voltage range: 90 - 264 V AC<br />

Input frequency: 50 - 60 Hz<br />

Input current:<br />

Output<br />

5.5 A at 115 V AC<br />

3 A at 230 V AC<br />

Nominal output voltage: 24 V DC +/- 2%<br />

- at battery operation: typ. 26.5 - 19.5 V DC<br />

Output current: 12.5 A<br />

Output power: 288 W<br />

Battery capacity to be connected: 24 Ah<br />

Loading current: typ. 3.0 A<br />

Back-up time: approx. 1 hour<br />

Approvals<br />

Safety: EN 60950, SELV<br />

EMC, CE certified: EN 55022 class B<br />

ENV 50204; EV 61000-3-2<br />

EN 61000-4-2, -3, -4, -5, -6, -8, -11<br />

Protection class: Class I<br />

Degree of protection:<br />

Connections<br />

IP 20<br />

Mains input: Direct mains connection<br />

via internal screw clamp<br />

Battery connection: Screw clamp<br />

Outputs:<br />

General<br />

Pluggable via clamp<br />

Ambient temperature: 0 ... +50 °C<br />

Storage temperature: -25 ... +60 °C<br />

MTBF: 100000 hours<br />

Weight.: 4 kg<br />

Dimensions (HxWxD): 244 x 325 x 178 mm<br />

Colour: RAL 7035 Light grey<br />

Order number Product name Notes<br />

77 3400 10 Power supply unit UPS 60<br />

Necessary accessories, order separately:<br />

77 3450 00 Battery set for UPS 60 Refer to separate data sheet<br />

Spare parts, order if required:<br />

00 0211 39 Connector for control and message outputs, 7-pole<br />

00 0211 40 Connector for mains connection, 3-pole<br />

00 0211 41 Connector for 24 V connection, 4-pole<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 59


Battery set for UPS 60<br />

77 3450 00<br />

General description<br />

Batteries which build in connection with the power<br />

supply unit UPS 60 an uninterruptable power sup‐<br />

ply (UPS) with approx. 1 hour backup power sup‐<br />

ply.<br />

Closed housing in protection class III. Designed for<br />

wall mounting in rooms, preferably below the power<br />

supply unit UPS 60.<br />

Technical data<br />

Input<br />

Nominal input voltage: 24 VDC<br />

Output<br />

Output current: 12.5 A<br />

Output voltage: typ. 26.5 - 19.5 V DC<br />

Battery capacity: 24 Ah<br />

Approvals<br />

Safety: EN 60950, SELV<br />

Protection class: Class III<br />

Degree of protection: IP 20<br />

Connection<br />

to power supply unit: Screw clamp<br />

General<br />

Ambient temperature: 0 ... +50 °C<br />

Storage temperature: -20 ... +50 °C<br />

Weight.: 25.2 kg<br />

Dimensions (HxWxD): 244 x 450 x 178 mm<br />

Colour: RAL 7035 Light grey<br />

Order number Product name Notes<br />

77 3450 00 Battery set for UPS 60<br />

Necessary accessories, order separately:<br />

77 3400 10 Power supply unit UPS 60 Refer to separate data sheet<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 60


Power supply unit 5A<br />

19 2103 02<br />

General description<br />

Power supply unit for supplying power to the nurse<br />

call system. The number of rooms that can be con‐<br />

nected is project-specific. Flush-mounted unit. The<br />

connection must be made with fixed wiring.<br />

Input<br />

Rated input voltage: Ue: 120-230 / 230-500 V AC, 50/60 Hz<br />

Input current Ie at 120/230V: 2,2/1,2 Aeff Recommended circuit-breaker characteristic C 6 A<br />

for 1-phase AC systems.<br />

To protect a system in a two-phase operation on<br />

two outer conductors of a three-phase system,<br />

protection must be provided by either a two-pole<br />

coupled line-protection circuit breaker or a motor<br />

circuit breaker, using the outer contact pairs.<br />

Order number Product name Note<br />

19 2103 02 Power supply unit 5A<br />

Power consumption (active power): 140 W<br />

Output<br />

Output DC voltage Ua: Delivery state: 24 V +/-1%<br />

Setting range 24 V to 28,8 V (set via potentiometer<br />

on front of unit)<br />

Direct output current Ia: 0 - 5 A<br />

Environment<br />

Temperature<br />

for storage and shipment: -25 °C to +85 °C<br />

for operation: 0 °C to +60 °C<br />

Climatic category: 3K3<br />

Standards<br />

Degree of protection: IP20<br />

Protection class: 1<br />

Safety to EN 60950: SELV<br />

Safety separation afforded according to EN60950;<br />

EN 50178;VDE 0100 Part 410; EN 61140+EN<br />

60947-1; UL508; CSA C22.2<br />

Interference emission to EN 50081-1<br />

RI suppression according to EN 55022, limit-value<br />

curve B<br />

Interference immunity to EN 61000-6-2<br />

Limitation of input current harmonics to EN<br />

61000-3-2<br />

Signalling<br />

LED green: Output voltage >20,5 V<br />

LED amber: Overload, output voltage < 20,5 V (in<br />

”Constant current” mode only)<br />

General<br />

Weight: 1,2 kg<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 61


11. Appendix: Accessories<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 62


Order no. Designation<br />

19 0700 90 Mounting kit for Terminal or GE<br />

Wall bracket and connectors for securing and wiring up<br />

a terminal or the group electronic of the<br />

<strong>CONCENTOPLUS</strong> or Concento system.<br />

- Screw attachment<br />

- Material: ABS<br />

- Weight of mounting plate: 60 g<br />

- Dimensions (HxWxD): 172 x 79 x 16 mm<br />

- Colour: alpine white, similar to RAL 9010<br />

- Suitable for 2-gang back box<br />

- Plug-in screw connector, 4-pole, as connector for<br />

voltage supply, maximum wire cross section 2.5 mm2 - Plug-in screw connector, 10-pole, as connector, with<br />

reverse polarity protection<br />

- Plug-in screw connector, 12-pole, as connector, with<br />

reverse polarity protection<br />

19 1421 10 Pull cord kit for Terminal<br />

Pull cord switch as an optional accessory for terminals<br />

of the <strong>CONCENTOPLUS</strong> or Concento system, for initia‐<br />

ting calls by pulling the cord.<br />

- Switch for installation in the wall bracket<br />

- Red pull cord, length 1.5 m<br />

- Red triangular handle with symbol<br />

- 120 kOhm terminating resistor for call monitoring<br />

- 14 cm connecting cable, 2-pole with plug, to be<br />

connected at input R7 of the terminal<br />

- Pulling force for initiation approx. 400 g<br />

- Installation in the mounting kit for terminal<br />

19 0800 92 Surface mounting frame for mounting kit<br />

For surface mounting a terminal or the group electronic<br />

of the <strong>CONCENTOPLUS</strong> or Concento system in con‐<br />

junction with the mounting kit, order no. 19 0700 90.<br />

Mounting plate in white Resopalit with rounded ABS<br />

safety edges.<br />

Dimensions (HxWxD): 172 x 79 x 19 mm<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 63


Order no. Designation<br />

19 0790 04 Self-releasing adapter pear push switch<br />

Device protection for connecting pear push switches,<br />

order no. 19 0790 xx. Consisting of plug and socket for<br />

pear push switch with 8-pole mini-DIN plug.<br />

- Length: 20 cm<br />

- Colour: white, similar to RAL 9010<br />

19 0790 06 Extension cable for pear push switch, 5 m<br />

Extension cable for pear push switches, order no. 19<br />

0790 xx. Consisting of 5-metre cable and plug and<br />

socket for pear push switch with 8-pole mini-DIN plug.<br />

- Length: 5 metres<br />

- Colour: white, similar to RAL 9010<br />

70 0361 00 Equipment and cable clamp<br />

Pragmatic protection for all equipment operated by pati‐<br />

ents. Exact guidance of all cables and equipment along<br />

the bed rail or the ”bed gallows”.<br />

No more damage due to the patient's attempt to pull<br />

themselves up on expensive technical equipment: The<br />

equipment and cable clamp detaches itself automati‐<br />

cally from the rail in the event of pulling.<br />

- Various attachment possibilities for different cable<br />

diameters<br />

- For using hoses or cables with a diameter of 4, 5, 6<br />

and 9 mm (e.g. pear push switch, patient handset,<br />

hearing tube)<br />

- The symmetrical design allows 2 equipment holders<br />

to be put together mirror-inverted in order to double<br />

the holding strength<br />

- Can also be used for other equipment in the hospital<br />

- Weight: 23 g<br />

- Colour: RAL 7035 light grey<br />

- Material: ABS<br />

Dimensions: max. height: 160 mm<br />

max. thickness: 18 mm<br />

Width: 70 mm<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 64


Order no. Designation<br />

19 9201 00 Central plate for 2 buttons<br />

Central plate for call/presence combination bus or for<br />

call & cancel switch/WC.<br />

- Material: ABS<br />

- Colour: alpine white, similar to RAL 9010<br />

- External dimensions: 55 x 55 mm<br />

19 9201 04 Central plate for<br />

1 button & 1 connection socket<br />

Central plate for call switch with connection socket.<br />

- Material: ABS<br />

- Colour: alpine white, similar to RAL 9010<br />

- External dimensions: 55 x 55 mm<br />

19 9201 06 Central plate for 1 button<br />

Central plate for call switch or cancel switch/WC.<br />

- Material: ABS<br />

- Colour: alpine white, similar to RAL 9010<br />

- External dimensions: 55 x 55 mm<br />

19 9201 08 Central plate for<br />

1 button & 2 connection sockets<br />

Central plate for call switch with 2 connection sockets.<br />

- Material: ABS<br />

- Colour: alpine white, similar to RAL 9010<br />

- External dimensions: 55 x 55 mm<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 65


Order no. Designation<br />

19 9200 06 Frame Jung AS 500<br />

- Frame, single, 81 x 81 mm<br />

- Internal dimensions: 55 mm<br />

- Colour: White<br />

- Manufacturer's article no.: AS 581 WW<br />

19 9200 03 Frame Gira Standard 55<br />

- Frame, single, 81 x 81 mm<br />

- Internal dimensions: 55 mm<br />

- Colour: Pure white, silky matt<br />

- Manufacturer's article no.: 021104<br />

19 9200 07 Frame Gira Standard 55 glossy<br />

- Frame, single, 81 x 81 mm<br />

- Internal dimensions: 55 mm<br />

- Colour: Pure white, glossy<br />

- Manufacturer's article no.: 021103<br />

19 9200 04 Frame Merten System M-SMART<br />

- Frame, 1-fach, 81 x 81 mm<br />

- Internal dimensions: 55 mm<br />

- Colour: polar white, classy matt<br />

- Manufacturer's article no.: 484119<br />

19 9200 05 Frame Berker S.1<br />

- Frame, single, 81 x 81 mm<br />

- Internal dimensions: 55 mm<br />

- Colour: polar white, matt<br />

- Manufacturer's article no.: 1011 99 09<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 66


Order no. Designation<br />

19 8000 00 Personal Computer, German<br />

Personal Computer e.g. for ConLogPLUS Management<br />

Software. Minimum configuration compatible with in‐<br />

dustry standard:<br />

- Processor model: Intel Celeron Dual Core E3400<br />

- Main memory: 4 GB DDR3<br />

- Hard drive: 250 GB<br />

- Optical drive: DVD burner<br />

- Network card: Ethernet 10/100/100 Mbps<br />

- Keyboard, mouse<br />

- Operating system: Windows 7 Professional 32-bit,<br />

German<br />

- VGA, DisplayPort, serial connection, Ethernet,<br />

several USB 2.0, 3x PCI<br />

- Serial COM port<br />

- 17 inch TFT monitor<br />

- Supply voltage: 230 V AC / 50 Hz<br />

The version corresponds with the respective standard<br />

equipment available for delivery. Further details on<br />

request.<br />

19 8001 00 Personal Computer, English<br />

same as 19 800 00, but in English.<br />

19 0800 14 Null-modem cable<br />

e.g. for connecting the Management Interface to paging<br />

system.<br />

- Sub-D, 9-pole, socket/socket<br />

- Length: 3 m<br />

19 0800 15 Serial extension cable<br />

e.g. for connecting the ConLogPLUS Management Soft‐<br />

ware to the Management Interface.<br />

- 9-pole Sub-D<br />

- Length: 3 m<br />

19 0800 22 DCF77 radio clock module for PC<br />

For synchronising the nurse call system<br />

<strong>CONCENTOPLUS</strong> with the standard time of the DCF77<br />

transmitter.<br />

- LED display red/green<br />

- USB connection for the PC<br />

- CD with driver software<br />

- Cable length: 2 m<br />

Dimensions (HxWxD): 80 x 40 x 20 mm<br />

Similar to illustrated example<br />

Similar to illustrated example<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 67


Order no. Designation<br />

19 1990 12 Interface converter RS232 to RS485<br />

For converting RS 232 interfaces to RS-422/485 inter‐<br />

faces.<br />

- DTE/DCE selector switch<br />

- Bi-directional conversion<br />

- Monitor for TXD/RXD diagnosis<br />

- Asynchronous transmission<br />

- Full-duplex / half-duplex DCE/DTE mode<br />

- Transmission rate: 128 kbps<br />

- Range: 1.3 km<br />

- Device can be configured via three switches<br />

- Plastic housing<br />

- 9 V DC plug-in power supply unit included<br />

19 1990 55 Sub-D adapter cable<br />

- 9-pole Sub-D socket<br />

- 25-pole Sub-D plug<br />

- Length: 25 cm<br />

70 0890 97 Overvoltage protection circuit<br />

11 5350 00 Telephone interface relay<br />

For connecting analog telephones to a nurse call sys‐<br />

tem, for forwarding calls as a phone call.<br />

- Call voltage: 32 - 80 V AC<br />

- Power supply: 5 - 40 V<br />

- On/Off switch<br />

- Switch output: Changeover contact<br />

- Adjustable call pause bridging<br />

- Adjustable switching time of the output contact<br />

Dimensions (HxWxD): 70 x 35 x 70 mm<br />

Mounting on 35 mm DIN rail<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 68


Order no. Designation<br />

77 0189 00 Doorplate universal<br />

Doorplate without light sections, for universal use.<br />

Suitable for installation on walls, in corridors or in<br />

rooms. Modular design.<br />

- Universal modular doorplate<br />

- Labelling easily changed<br />

- Simple mounting<br />

Dimensions (HxWxD): 190 x 150 x 40 mm<br />

Label field (HxW): approx. 70 x 92 mm<br />

Z 00 8203 10 Room plate<br />

Doorplate as label field for the room name.<br />

- Convex shape<br />

- Nameplate can be changed as desired<br />

- Can be fitted onto size 55 switch box or various<br />

flush-mounted boxes<br />

Dimensions (HxWxD): 126 x 150 x 40 mm<br />

Z 00 8203 20 Room plate with backlighting<br />

Doorplate as label field for the room name.<br />

- Convex shape<br />

- Nameplate can be changed as desired<br />

- Can be fitted onto size 55 switch box or various<br />

flush-mounted boxes<br />

- Backlighting as LED display, power consumption:<br />

30 mA via separate power supply<br />

Dimensions (HxWxD): 126 x 150 x 40 mm<br />

Z 00 8203 00 Apartment plate<br />

Doorplate as label field for the apartment name.<br />

- Convex shape<br />

- Nameplate can be changed as desired<br />

Dimensions (HxWxD): 120 x 148 x 24 mm<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 69


Order no. Designation<br />

70 0807 07 Connector, 7-pole<br />

Plug-in screw terminal, e.g. for connecting the universal<br />

room lamps.<br />

- Screw plug connection up to 1.5 mm2 - Reverse polarity protection<br />

Dimensions (HxWxD): 10 x 28 x 15 mm<br />

19 0702 82 Diagnostic connection cable<br />

For connecting an electrical medical device to a<br />

connection socket.<br />

- Length: 3 m<br />

- 8-pole mini-DIN plug<br />

- Strain relief<br />

- Free wire ends<br />

Z 00 8202 20 Magnetic wall bracket<br />

Bracket for magnetically securing a radio receiver<br />

869.2125 MHz on the wall next to the call switch with<br />

connection socket.<br />

Dimensions (HxWxD): 60 x 25 x 10 mm<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 70


Order no. Designation<br />

17 0100 00 Back box solid wall, 1-gang<br />

Dimensions: Ø 66 mm / T 42 mm<br />

17 0410 00 Back box solid wall, 2-gang<br />

Dimensions (HxWxD): 140 x 69 x 42 mm<br />

17 5100 00 Back box partition wall, 1-gang<br />

Dimensions: Ø 68 mm / T 45 mm<br />

17 5400 00 Back box partition wall, 2-gang<br />

Dimensions (HxWxD): 142 x 68 x 45 mm<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 71


12. Services<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 72


Order no. Designation<br />

19 0000 63 Initial start-up assistance/Commissioning support for CONCENTO nurse<br />

call system<br />

Initial start-up assistance/commissioning support by the manufacturer. Flat-rate inside<br />

Germany, including flat-rate travel costs, plus accommodation and special surcharges such<br />

as overtime and public holiday surcharges, on site for 1 day (8 hours).<br />

Other countries on request.<br />

Target group: Electrical installation companies<br />

After the nurse call system has been installed, our service technician will support you during<br />

the structured nurse call system commissioning procedure.<br />

19 0000 64 System introduction to CONCENTO nurse call system<br />

System introduction by the manufacturer. Flat-rate inside Germany, including flat-rate travel<br />

costs, plus accommodation and special surcharges such as overtime and public holiday<br />

surcharges, on site for half a day (4 hours).<br />

Other countries on request.<br />

Target group: Nurses/male nurses, operators, site technicians.<br />

Following commissioning and handover of the nursecall system, the operator is responsible<br />

for staff instruction and for ensuring that staff have sufficient knowledge of how to operate<br />

and use the nurse call system.<br />

The German standard DIN VDE 0834 4/2000 provides detailed instructions about this. In‐<br />

struction must be provided by trained experts!<br />

Our service technician will instruct operators on site on the wards in how to operate the<br />

nurse call system. The system functions will be explained and demonstrated in detail with<br />

reference to the operating instructions, e.g. notification of presence, call handling, call for‐<br />

warding etc.<br />

Participants will be fully familiarised with the system. A list of participants confirms the in‐<br />

struction measure.<br />

19 0000 70 Preparation of a project specific database (per 10 rooms) for CON‐<br />

CENTO nurse call system<br />

A database containing the project-specific data is required for configuring a nurse call sys‐<br />

tem <strong>CONCENTOPLUS</strong> or Concento. We will prepare this database for you on the basis of<br />

your specified project-specific data.<br />

This order number must be ordered per 10 rooms.<br />

<strong>Tunstall</strong> <strong>GmbH</strong> CONCENTO PLUS <strong>Data</strong> sheet 11/2012 We reserve the right to make technical changes 73

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!