You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
SPINAL COLUMN ANALYSIS<br />
Assessment of the Mobility of the Cervical<br />
and Lumbar Spinal Column<br />
With special triple markers based The report shows the maximum<br />
on miniature ultrasonic transmitters, mobility - the range of motion<br />
simple and rapid function tests can (ROM). A diagram is presented<br />
be carried out on the cervical and for each main direction of move-<br />
lumbar spinal column and on the ment: flexion / extension, rotation<br />
entire torso.<br />
and lateral flexion.<br />
The measuring sensor mounted on<br />
a floor stand detects the travel time<br />
of the ultrasonic signals and<br />
transmits the results to the basic<br />
unit.<br />
During the measurement the patient<br />
makes fluent movements to<br />
his maximum mobility.<br />
Report<br />
The quality of performance of<br />
the movements is shown in<br />
phase diagrams taking into<br />
consideration the speed of the<br />
movements.<br />
The ability of the patient to reproduce<br />
movements can be seen<br />
in the coefficient of variability.<br />
In the analysis of lumbar spinal<br />
column movements, the synkinesis<br />
between lateral inclination<br />
and pelvic rotation as well as<br />
the coordination between hip and<br />
lumbar spine during flexion /<br />
extension are shown.<br />
Bar charts overlayed<br />
by standard ranges<br />
Output of<br />
Maximum mobility<br />
(ROM)<br />
Phase diagrams with<br />
speed anlysis<br />
<strong>zebris</strong><br />
Simple and fast data<br />
acquisition using the<br />
<strong>zebris</strong> measuring<br />
systems based on the<br />
principle of the travel<br />
time measurement of<br />
ultrasonic pulses<br />
"WinSpine" program<br />
supported by up to date<br />
Windows operating<br />
systems<br />
Coefficient of<br />
variability<br />
Coordination of<br />
movement<br />
Synkinesis between<br />
lateral inclination and<br />
pelvic rotation<br />
Coupling pattern<br />
For further information<br />
please contact<br />
<strong>zebris</strong> <strong>Medical</strong> <strong>GmbH</strong><br />
Max-Eyth-Weg 42<br />
D-88316 Isny i. Allgäu<br />
Germany<br />
Tel.: +49 7562 / 9726-0<br />
Fax: +49 7562 / 9726-50<br />
E-mail: <strong>zebris</strong>@<strong>zebris</strong>.de<br />
Internet: www.<strong>zebris</strong>.de<br />
© <strong>zebris</strong> 05/2004
NEU<br />
Accessories<br />
Head attachment<br />
with triple<br />
markers and<br />
reference marker<br />
for cervical spine<br />
measurement<br />
Attachment set<br />
with triple<br />
markers for<br />
lumbar spine<br />
analysis<br />
Technical modifications reserved<br />
<strong>zebris</strong>