<strong>The</strong> <strong>World</strong> <strong>of</strong> <strong>Biomechanics</strong> <strong>zebris</strong> <strong>Medical</strong> <strong>GmbH</strong><br />

Simple and Precise - the <strong>zebris</strong><br />

Jaw Measurement Analysis System<br />

<strong>The</strong> <strong>zebris</strong> JMA measuring system for contact-free<br />

recording<strong>of</strong>allthelowerjaw,functionsusinga<br />

new type <strong>of</strong> ultrasonic sensor technology measuring<br />

in the proximity <strong>of</strong> the joint.<br />

<strong>The</strong> extremely light, equilibrated lower jaw sensor<br />

is fixed to the front teeth using a paraocclusal<br />

attachment.<br />

Reference points can be entered using a probe tip.<br />

<strong>The</strong> receiver sensor equipment is integrated in the<br />

facebow.<br />

In addition to various possibilities for function<br />

<strong>zebris</strong> <strong>Medical</strong> <strong>GmbH</strong>, Max-Eyth-Weg 42, 88316 Isny i. Allgäu, Germany<br />

tel. +49 7562/9726-0, fax +49 7562/9726-50, email: <strong>zebris</strong>@<strong>zebris</strong>.de, internet: www.<strong>zebris</strong>.de<br />

analysis, the added value is gained by the timesaving<br />

when correcting the dynamic occlusion.<br />

For this, an automatic computation <strong>of</strong> the<br />

characteristic data <strong>of</strong> current, fully-adjustable<br />

articulators is carried out (SAM®, Panadent,<br />

PROTAR®, ARTEX®, Reference® and STRATOS®) .<br />

Optionally,thesystemcanbefittedwitha<br />

4-channel myography system.<br />

<strong>The</strong> control and evaluation is carried out using<br />

a commercially available PC.<br />

NEW<br />

<strong>zebris</strong>


<strong>zebris</strong> JMA20 System ( Jaw Motion Analysis)<br />

Technical Data<br />

Measuring principle: travel time measurement <strong>of</strong> ultrasound pulses<br />

System JMA20<br />

Basic unit 75 x 150 x 266 mm (W xHxD)<br />

Weight 1,9 kg<br />

Buffer memory 60 KB<br />

USB Port to PC<br />

Optional: 4 analog channels 1000 Hz<br />

Fixation <strong>of</strong> the face bow: cushioned supporting surface,<br />

supporting band running over the head, adjustable nosepad<br />

Fixation <strong>of</strong> the measuring sensor: paraocclusal, using adhesive<br />

or a mounting aid<br />

Weight exerted on the lower jaw by sensor equipment:<br />

approx. 50g/28g(optional)<br />

Weight <strong>of</strong> the face bow with receiver sensors:<br />

approx. 170 g<br />

Measurement resolution: 0.01 mm<br />

Average local measurement error: approx. 0,1 mm<br />

Measuring resolution: 75 measurement/s (typ.)<br />

S<strong>of</strong>tware: runs under Windows XP<br />

Performable measurements<br />

Adjustment <strong>of</strong> articulator<br />

Function analysis<br />

EPA - Electronic Position Analysis <strong>of</strong> the condyles<br />

Determination <strong>of</strong> palatinal front teeth contour (optional)<br />

Myography - EMG (optional)<br />

Analysis <strong>of</strong> chewing movements (in preparation)<br />

Performance range<br />

Entry <strong>of</strong> reference levels (FP or CP) with probe tip<br />

Determination <strong>of</strong> arbitrary, terminal or kinematic articulation axes<br />

Display <strong>of</strong> movement tracks (computation module for angles and distances)<br />

Entry and determination <strong>of</strong> any reference points using a probe tip<br />

3D-animation <strong>of</strong> the temperomandibular articulation movement<br />

Translation/rotation velocity diagram showing the protrusion movement <strong>of</strong> the<br />

intercondylar axis<br />

Automatic computation <strong>of</strong> the characteristic data <strong>of</strong> current, fully-adjustable articulators<br />

SAM®, PROTAR®, ARTEX®, STRATOS®, Panadent, Reference®<br />

Superimposition <strong>of</strong> kinematic measuring data with analog data (EMG)<br />

Output <strong>of</strong> standard reports<br />

Data export<br />

4 channel myography EMG (optional)<br />

Technical modifications reserved<br />

© <strong>zebris</strong> 08/2005<br />