Appendix<br />

Table 1<br />

August 2010<br />

European Commissi<strong>on</strong><br />

Employment, Social Affairs and Inclusi<strong>on</strong><br />

<str<strong>on</strong>g>Recommendati<strong>on</strong></str<strong>on</strong>g> <str<strong>on</strong>g>from</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> <str<strong>on</strong>g>Scientific</str<strong>on</strong>g> <str<strong>on</strong>g>Committee</str<strong>on</strong>g> <strong>on</strong> Occupati<strong>on</strong>al Exposure Limits for aniline<br />

The two OSHA methods, OSHA method PV 2118 and a modified versi<strong>on</strong> of <str<strong>on</strong>g>the</str<strong>on</strong>g> OSHA<br />

method PV 2118, gave virtually similar results and results were not significantly influenced<br />

by humidity or temperature (McKernan et al. 2008). Thus, results <str<strong>on</strong>g>from</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> NIOSH (limit of<br />

detecti<strong>on</strong>: 0.6 µg/sample and limit of quantitati<strong>on</strong>: 2 µg/sample (Pendergrass 2004)) and<br />

<str<strong>on</strong>g>the</str<strong>on</strong>g> modified OSHA method are tabulated below. The OSHA method has a higher<br />

detecti<strong>on</strong> limit than <str<strong>on</strong>g>the</str<strong>on</strong>g> NIOSH method (http://www.osha.gov/dsg/guidance/101707diacetyl-meeting-notes.html,<br />

accessed 12, December 2008). In c<strong>on</strong>sequence,<br />

comparis<strong>on</strong>s were not included where <str<strong>on</strong>g>the</str<strong>on</strong>g> NIOSH method detected diacetyl, but no<br />

diacetyl was detected in <str<strong>on</strong>g>the</str<strong>on</strong>g> modified OSHA method (Table I: [NIOSH (+);OSHA (0)]/N<br />

samples= 4/24 and Table II: [NIOSH (+);OSHA (0)]/N samples= 3/30 (McKernan et al. 2008));<br />

this would presumably have a limited influence <strong>on</strong> <str<strong>on</strong>g>the</str<strong>on</strong>g> comparis<strong>on</strong> between <str<strong>on</strong>g>the</str<strong>on</strong>g> two<br />

methods due to <str<strong>on</strong>g>the</str<strong>on</strong>g> limited number of data points excluded. The ratio between a result<br />

<str<strong>on</strong>g>from</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> OSHA and <str<strong>on</strong>g>the</str<strong>on</strong>g> NIOSH method (B/A) cannot be calculated where <str<strong>on</strong>g>the</str<strong>on</strong>g> OSHA<br />

method detects diacetyl, but <str<strong>on</strong>g>the</str<strong>on</strong>g> NIOSH method detects no diacetyl (Table I: [NIOSH<br />

(0);OSHA (+)]/N samples= 3/24 and Table II: [NIOSH (+);OSHA (0)]/N samples = 14/30<br />

(McKernan et al. 2008)) as such a ratio will be infinite. Thus, <str<strong>on</strong>g>the</str<strong>on</strong>g>se values have to be<br />

excluded <str<strong>on</strong>g>from</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> calculati<strong>on</strong>s; Table I allowed <str<strong>on</strong>g>the</str<strong>on</strong>g> use of 15/24 and Table II <str<strong>on</strong>g>the</str<strong>on</strong>g> use of<br />

5/30 data pairs (cf. McKernan et al. 2008). This lends a limited credit to a ratio calculated<br />

<str<strong>on</strong>g>from</str<strong>on</strong>g> <str<strong>on</strong>g>the</str<strong>on</strong>g> values of <str<strong>on</strong>g>the</str<strong>on</strong>g> remaining data pairs, which are listed below.<br />

Table<br />

McKernan et al. 2008<br />

NIOSH<br />

(ppm) (A)<br />

OSHA modified<br />

(ppm) (B)<br />

B/A<br />

I 0.04 0.11 2.75<br />

I 0.02 0.04 2.00<br />

I 0.07 0.08 1.14<br />

I 0.04 0.12 3.00<br />

I 0.1 0.15 1.50<br />

I 0.01 0.04 4.00<br />

I 0.42 0.54 1.29<br />

I 0.08 0.16 2.00<br />

I 0.02 0.16 8.00<br />

I 0.17 0.35 2.06<br />

I 0.02 0.07 3.50<br />

I 0.39 0.48 1.23<br />

I 1.05 1 0.95<br />

I 0.05 0.37 7.40<br />

I 0.02 0.04 2.00<br />

II 0.05 0.63 12.60<br />

II 0.57 1.58 2.77<br />

II 0.08 0.14 1.75<br />

II 0.53 6.33 11.94<br />

II 0.03 0.03 1.00<br />

Mean (range): 3.64<br />

(0.95-12.60)<br />

18