Protecting Property, Life and the Environment <strong>News</strong>letter No 17 Page 6<br />

New Products and services<br />

The “Shawston Firesleeve” will save you in labour time due to its unique Snap Lock Design.<br />

As you will be aware there is increasing responsibility placed on contractors to make good any area where the services penetrate<br />

a firewall. To assist you in doing this Shawston have put a wide range of the most common fire stopping products into<br />

stock.<br />

The “Shawston Firesleeve” is suitable for fire containment in both plasterboard and block work walls for a 2-hour rated seal. It<br />

has a stainless steel sleeve lined with a high expansion intumescent compound overlaid with a fire resistant acoustic foam<br />

compression seal.<br />

Viking Offers ESFR Protection in Freezers<br />

The Viking Corporation announces a new system for protecting freezer and cold storage environments. This new system, utilizing Vi-<br />

king’s K25 ESFR Pendent <strong>Sprinkler</strong>s (VK510) and a pre-mix of propylene glycol antifreeze and water, can enhance flexibility by eliminat-<br />

ing in-rack sprinklers in certain applications. Testing utilizing Viking’s K25 ESFR <strong>Sprinkler</strong> has been completed, and UL Listing is pend-<br />

ing.<br />

Viking’s K25 Antifreeze System protects up to Class II Storage Commodities in buildings up to 40 feet<br />

(12,2 m) high with racked storage up to 35 feet (10,7 m). The listing is for the 165° F (74° C) Viking<br />

K25 ESFR <strong>Sprinkler</strong> (VK510), though intermediate temperature sprinklers rated to 205° F (96° C) may<br />

be applied as referenced in NFPA 13 for installation in close proximity to heat sources. This special<br />

application for the K25 ESFR <strong>Sprinkler</strong> requires a minimum starting pressure of 40 psi (278 kPa) and<br />

has a maximum volume of antifreeze solution per system of 1100 gallons (4163 liters).<br />

The Viking K25 Antifreeze System provides a cost effective alternative to in-rack sprinkler systems for<br />

protecting storage environments as cold as –23° F (-30.6° C). In addition to having a positive impact on<br />

total installed cost, the system is also far less vulnerable to damage than traditional in-rack sprinklers.<br />

Viking Introduces New Concealed Dry <strong>Sprinkler</strong>s (see photo)<br />

This new line includes both standard response and quick response versions for both standard coverage<br />

and extended coverage applications.<br />

Standard Coverage Extended Coverage<br />

Standard Response (1” NPT) 5.6 (8,1) K-factor 5.6 (8,1) K-factor<br />

8.0 (11,5) K-factor<br />

Quick Response (1” NPT) 5.6 (8,1) K-factor 5.6 (8,1) K-factor<br />

The push-on, thread-off cover design allows for easy installation after the system has been tested and the ceiling has been finished. The<br />

cover provides ½” (12,7mm) vertical adjustment, a critical factor for proper installation of concealed sprinklers. It is only 3-1/8” (80mm) in<br />

diameter, may be removed without taking the system out of service and is available in chrome, white, ivory, black and custom colors.<br />

Protect Combustible Concealed Spaces with New Viking COIN <strong>Sprinkler</strong><br />

The new COIN Quick Response Combustible Interstitial Space <strong>Sprinkler</strong> has been tested and listed for use in specific light hazard com-<br />

bustible and non-combustible concealed horizontal spaces requiring sprinkler protection per installation standards. In some cases, it can<br />

allow the use of any listed CPVC piping system within concealed spaces requiring sprinkler protection.<br />

With extended cov erage listings for spacing up to 12’ x 12’ (3,7m x 3,7m), the COIN <strong>Sprinkler</strong> can be used with Wet Pipe Systems using<br />

steel or any listed CPVC pipe, or Dry Pipe Systems using galvanized steel pipe.<br />

The COIN sprinkler (VK900) is cULus Listed. It has a 4.2 (6,0 metric) K-factor and a starting pressure of 11.8 psi (81,4 kPa) at its maximum<br />

spacing and .1 gpm/ft 2 (4,1mm/min) density. Minimum starting pressure is 8 psi (55 kPa).<br />