<strong>RETEC</strong> <strong>Electrolytic</strong> <strong>Cells</strong><br />

Application field<br />

The <strong>RETEC</strong> <strong>Electrolytic</strong> cells have been used<br />

for metal recovery since more than 20 years.<br />

<strong>RETEC</strong> – cells are ideally suited for the<br />

recovery of gold, silver, copper, cadmium and<br />

nickel. The systems are simply designed,<br />

inexpensive and highly efficient.<br />

<strong>RETEC</strong> – cells can be installed for example<br />

next to a rinsing bath in order to reduce<br />

continuously the content of metal ions.<br />

Process Characteristics<br />

The metal ions present in the solution are<br />

reduced and deposited as metal on the<br />

surface of foamed cathodes which are made<br />

either of copper or of nickel.<br />

The cathode offers a very large effective<br />

surface. It enables an effective elimination of<br />

dissolved metal ions, even at a very low<br />

concentration (a few ppms).<br />

When one of the cell cathodes is fully charged<br />

with metal, the metallised cathode may either<br />

be sold for the metal value or used as an<br />

anode in a recycling unit.<br />

The Anodes are available in different qualities<br />

and consist of a titanium mesh covered with a<br />

noble-metal catalyst.


<strong>RETEC</strong> <strong>Electrolytic</strong> <strong>Cells</strong><br />

<strong>RETEC</strong><br />

Type<br />

02 07 6 15 25 50 CP3 CP6 CP9<br />

Useful<br />

volume [l]<br />

7 12 80 145 217 360 70 90 120<br />

Length x<br />

width [cm]<br />

27 x 32 54 x 26 55 x 55 82 x 58<br />

111 x<br />

58<br />

183 x<br />

58<br />

95 x 70 120 x 70 145 x 70<br />

Height [cm] 34 36 140 140 140 140 150 150 150<br />

Cathodes<br />

number<br />

2 7 6 15 25 50 4 7 10<br />

Cathode<br />

type<br />

Over all<br />

Type 1 Type 1 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2 Type 2<br />

cathode<br />

surface [dm²]<br />

8,2 28,7 105 262,5 437,5 875 70 122,5 175<br />

Anode<br />

number<br />

3 8 7 16 26 51 3 6 9<br />

Max. current<br />

per cell [A]<br />

10 20 100 250 500 1000 180 360 540<br />

Max. voltage<br />

per cell [V]<br />

10 10 10 10 10 10 10 10 10<br />

Flow rate<br />

pump max.<br />

[l/h]<br />

600 600 1600 1600 1600 1600<br />

1340<br />

2000<br />

1340<br />

2000<br />

1340<br />

2000<br />

Special<br />

Divided Divided Divided<br />

construction<br />

chambers<br />

with<br />

chambers<br />

with<br />

chambers<br />

with<br />

membrane membrane membrane<br />

Description of plant<br />

<strong>RETEC</strong> – cells are available in different sizes and can contain from 2 up to 50 cathodes. The systems<br />

are delivered fully equipped with rectifier and easy to install.<br />

The electrolyte is introduced at one end of the cell, passes through the cell and is evacuated through an<br />

overflow at the other end. The dissolved metal in the electrolyte is deposited on the surface of the<br />

cathodes.<br />

Cathodes are available from stock in two different sizes.<br />

Type 1: 18 x 23 cm, Type 2: 46 x 38 cm, each in Cu and Ni version<br />

For pilot testing, <strong>Gütling</strong> provides the customers with rental units which allow checking of system<br />

functionality and efficiency.<br />

<strong>Gütling</strong> <strong>Wassertechnologie</strong><br />

Merowingerstraße 7<br />

D - 70736 Fellbach<br />

Tel.: + 49 (0) 711/518550 – 0<br />

Fax: + 49 (0) 711/518550 – 220<br />

www.guetling.com<br />

guetling@veoliawater.com<br />

Advantages<br />

OVERFLOW<br />

ANODE SPACER<br />

AIR DISTRIBUTOR <br />

POWER SUPPLY<br />

CATHODE<br />

• Compact design<br />

• Low invest costs<br />

• High efficiency<br />

• Reduction of water consumption and labour costs by means<br />

of extension of rinse baths life time<br />

• Reduction of chemical consumption<br />

• Reduction of sludge amount<br />

• Little floor space requirements<br />

• Pilot cells available<br />

FILTER<br />

INLET AIR<br />

INLET ELECTROLYT<br />

12/2008