Data Generator for X-<strong>Ray</strong>s:<br />
• Nominal voltage of X-<strong>Ray</strong> tube: 70 kVp<br />
• Anodic Current: 8mA<br />
• Power: 560W<br />
• Target Material: Tungsten<br />
• Target Angle: 19º<br />
• Focal Point: 0,8 mm (IEC – 60336/1993)<br />
• Total Filtration: 2,5 mm Al<br />
• Isolation with silicone oil<br />
• Shielded cylindrical colimator<br />
Approximate Net Weight (standard):<br />
• Model Mobile Pedestal 90 kg (total)<br />
• Model Wall 40 kg (total)<br />
• Model Fixed Pedestal 45 kg (total)<br />
Input Data:<br />
TYPE I<br />
Voltage rating: 127VAC<br />
Current: 13A<br />
Frequency: 60Hz<br />
Power: 1,60kVa<br />
Fuse: 20A<br />
TYPE II<br />
Voltage rating: 220VAC<br />
Current: 7A<br />
Frequency: 60Hz<br />
Power: 1,60kVa<br />
Fuse: 12A<br />
TYPE III<br />
Current: 12A<br />
Voltage rating: 220VAC<br />
Frequency: 50Hz<br />
Power: 2,60kVa<br />
Fuse: 20A<br />
Pre-Setting<br />
The unit already has programs of<br />
exposure times for each combination,<br />
which can be adjusted according to<br />
the needs of the professional.<br />
Functions:<br />
Setting the exposure times;<br />
Choosing the completion of radiography<br />
on film or digital sensor;<br />
Setting the dental element;<br />
Selecting the age group.<br />
<strong>KaVo</strong> Headoffice<br />
Rua Chapecó, 86 - Saguaçu<br />
CEP 89221-040 - Joinville / SC<br />
Tel.: (47) 3451.0100 | Fax.: (47) 3451.0214<br />
E-mail: falecom@kavo.com<br />
<strong>KaVo</strong> 70 kVp X-<strong>Ray</strong><br />
Fixed Pedestal<br />
Composed of column fixed to the floor with<br />
articulated pantographic arm. Optional rotating arm<br />
in measures 510 mm or 760 mm or 1010 mm.<br />
2 e 3<br />
Selection of<br />
<strong>Dental</strong> Element<br />
1<br />
Patient Selection<br />
Child or Adult<br />
<strong>KaVo</strong> São Paulo Innovation Center<br />
Alameda dos Aicás, 527 - Moema<br />
CEP 04086-001 - São Paulo / SP<br />
Tel.: (11) 3323.0500 | Fax.: (11) 3323.0505<br />
E-mail: saopaulo@kavo.com<br />
| ALWAYS FOR YOU<br />
7<br />
4<br />
Select Bite<br />
Select Film Image<br />
or Digital Image<br />
5 e 6<br />
Selection of<br />
<strong>Dental</strong> Element<br />
<strong>KaVo</strong> Distrito Federal Innovation Center<br />
Edifício Brasília Rádio Center SRTN - Quadra 702<br />
Conjunto P - Asa Norte - Loja 3<br />
CEP 70719-900 - Brasília / DF<br />
Tel.: (61) 3326.3995 | Fax.: (61) 3327.7653<br />
E-mail: distritofederal@kavo.com<br />
Iimages merely illustrative. The technical characteristics listed in this brochure may change without notice. PRINTED FEB. 2010.