KaVo x-Ray (pdf, 3515.92 KB) - KaVo Dental
KaVo x-Ray (pdf, 3515.92 KB) - KaVo Dental
KaVo x-Ray (pdf, 3515.92 KB) - KaVo Dental
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Periapical X-<strong>Ray</strong> equipment, 70 kVp with a current of 8mA.<br />
The <strong>KaVo</strong> X-<strong>Ray</strong> equipment has full reproducibility of images, this means<br />
excellent picture quality in all x-ray photographs.<br />
Greater stability and ease of positioning, ensures complete security and<br />
reliability to you and your patients.<br />
Oil silicone-insulated head prevents wear on the coils and provides longer life.<br />
Easy-to-use head by handle allows greater stability and lower rates of<br />
maintenance.<br />
Circular collimador with 20 cm in length (from focal point to the end).<br />
Models:<br />
• Mobile Pedestal<br />
• Mobile Pedestal with Pre-Setting<br />
• Fixed Pedestal<br />
• Fixed Pedestal with Pre-Setting<br />
• Wall<br />
• Wall with articulated pantographic Pre-Setting<br />
The <strong>KaVo</strong> X-<strong>Ray</strong> uses silicone oil water-based with excellent dielectric properties, high chemical<br />
and thermal stability, oxidation resistance and higher fire safety. It is safe for the environment<br />
and contains no additives.<br />
<strong>KaVo</strong> X-<strong>Ray</strong><br />
Surprise yourself with this picture<br />
<strong>KaVo</strong> 70 kVp X-<strong>Ray</strong><br />
Mobile Pedestal<br />
Comprising pedestal cabinet with articulated<br />
pantographic arm and base with 4 casters.<br />
<strong>KaVo</strong> 70 kVp X-<strong>Ray</strong><br />
Wall<br />
Composed by bearing fixed to the<br />
wall with a articulated pantographic<br />
arm. Optional rotating arm in<br />
measures 510 mm or 760 mm<br />
or 1.010 mm.<br />
Digital Trigger<br />
Trigger with 5-meter cable, magnetic<br />
mounting, membrane keypad with<br />
exposure time adjustment and<br />
centesimal digital display for time<br />
viewing.
Data Generator for X-<strong>Ray</strong>s:<br />
• Nominal voltage of X-<strong>Ray</strong> tube: 70 kVp<br />
• Anodic Current: 8mA<br />
• Power: 560W<br />
• Target Material: Tungsten<br />
• Target Angle: 19º<br />
• Focal Point: 0,8 mm (IEC – 60336/1993)<br />
• Total Filtration: 2,5 mm Al<br />
• Isolation with silicone oil<br />
• Shielded cylindrical colimator<br />
Approximate Net Weight (standard):<br />
• Model Mobile Pedestal 90 kg (total)<br />
• Model Wall 40 kg (total)<br />
• Model Fixed Pedestal 45 kg (total)<br />
Input Data:<br />
TYPE I<br />
Voltage rating: 127VAC<br />
Current: 13A<br />
Frequency: 60Hz<br />
Power: 1,60kVa<br />
Fuse: 20A<br />
TYPE II<br />
Voltage rating: 220VAC<br />
Current: 7A<br />
Frequency: 60Hz<br />
Power: 1,60kVa<br />
Fuse: 12A<br />
TYPE III<br />
Current: 12A<br />
Voltage rating: 220VAC<br />
Frequency: 50Hz<br />
Power: 2,60kVa<br />
Fuse: 20A<br />
Pre-Setting<br />
The unit already has programs of<br />
exposure times for each combination,<br />
which can be adjusted according to<br />
the needs of the professional.<br />
Functions:<br />
Setting the exposure times;<br />
Choosing the completion of radiography<br />
on film or digital sensor;<br />
Setting the dental element;<br />
Selecting the age group.<br />
<strong>KaVo</strong> Headoffice<br />
Rua Chapecó, 86 - Saguaçu<br />
CEP 89221-040 - Joinville / SC<br />
Tel.: (47) 3451.0100 | Fax.: (47) 3451.0214<br />
E-mail: falecom@kavo.com<br />
<strong>KaVo</strong> 70 kVp X-<strong>Ray</strong><br />
Fixed Pedestal<br />
Composed of column fixed to the floor with<br />
articulated pantographic arm. Optional rotating arm<br />
in measures 510 mm or 760 mm or 1010 mm.<br />
2 e 3<br />
Selection of<br />
<strong>Dental</strong> Element<br />
1<br />
Patient Selection<br />
Child or Adult<br />
<strong>KaVo</strong> São Paulo Innovation Center<br />
Alameda dos Aicás, 527 - Moema<br />
CEP 04086-001 - São Paulo / SP<br />
Tel.: (11) 3323.0500 | Fax.: (11) 3323.0505<br />
E-mail: saopaulo@kavo.com<br />
| ALWAYS FOR YOU<br />
7<br />
4<br />
Select Bite<br />
Select Film Image<br />
or Digital Image<br />
5 e 6<br />
Selection of<br />
<strong>Dental</strong> Element<br />
<strong>KaVo</strong> Distrito Federal Innovation Center<br />
Edifício Brasília Rádio Center SRTN - Quadra 702<br />
Conjunto P - Asa Norte - Loja 3<br />
CEP 70719-900 - Brasília / DF<br />
Tel.: (61) 3326.3995 | Fax.: (61) 3327.7653<br />
E-mail: distritofederal@kavo.com<br />
Iimages merely illustrative. The technical characteristics listed in this brochure may change without notice. PRINTED FEB. 2010.