Periapical X-<strong>Ray</strong> equipment, 70 kVp with a current of 8mA.<br />

The <strong>KaVo</strong> X-<strong>Ray</strong> equipment has full reproducibility of images, this means<br />

excellent picture quality in all x-ray photographs.<br />

Greater stability and ease of positioning, ensures complete security and<br />

reliability to you and your patients.<br />

Oil silicone-insulated head prevents wear on the coils and provides longer life.<br />

Easy-to-use head by handle allows greater stability and lower rates of<br />

maintenance.<br />

Circular collimador with 20 cm in length (from focal point to the end).<br />

Models:<br />

• Mobile Pedestal<br />

• Mobile Pedestal with Pre-Setting<br />

• Fixed Pedestal<br />

• Fixed Pedestal with Pre-Setting<br />

• Wall<br />

• Wall with articulated pantographic Pre-Setting<br />

The <strong>KaVo</strong> X-<strong>Ray</strong> uses silicone oil water-based with excellent dielectric properties, high chemical<br />

and thermal stability, oxidation resistance and higher fire safety. It is safe for the environment<br />

and contains no additives.<br />

<strong>KaVo</strong> X-<strong>Ray</strong><br />

Surprise yourself with this picture<br />

<strong>KaVo</strong> 70 kVp X-<strong>Ray</strong><br />

Mobile Pedestal<br />

Comprising pedestal cabinet with articulated<br />

pantographic arm and base with 4 casters.<br />

<strong>KaVo</strong> 70 kVp X-<strong>Ray</strong><br />

Wall<br />

Composed by bearing fixed to the<br />

wall with a articulated pantographic<br />

arm. Optional rotating arm in<br />

measures 510 mm or 760 mm<br />

or 1.010 mm.<br />

Digital Trigger<br />

Trigger with 5-meter cable, magnetic<br />

mounting, membrane keypad with<br />

exposure time adjustment and<br />

centesimal digital display for time<br />

viewing.


Data Generator for X-<strong>Ray</strong>s:<br />

• Nominal voltage of X-<strong>Ray</strong> tube: 70 kVp<br />

• Anodic Current: 8mA<br />

• Power: 560W<br />

• Target Material: Tungsten<br />

• Target Angle: 19º<br />

• Focal Point: 0,8 mm (IEC – 60336/1993)<br />

• Total Filtration: 2,5 mm Al<br />

• Isolation with silicone oil<br />

• Shielded cylindrical colimator<br />

Approximate Net Weight (standard):<br />

• Model Mobile Pedestal 90 kg (total)<br />

• Model Wall 40 kg (total)<br />

• Model Fixed Pedestal 45 kg (total)<br />

Input Data:<br />

TYPE I<br />

Voltage rating: 127VAC<br />

Current: 13A<br />

Frequency: 60Hz<br />

Power: 1,60kVa<br />

Fuse: 20A<br />

TYPE II<br />

Voltage rating: 220VAC<br />

Current: 7A<br />

Frequency: 60Hz<br />

Power: 1,60kVa<br />

Fuse: 12A<br />

TYPE III<br />

Current: 12A<br />

Voltage rating: 220VAC<br />

Frequency: 50Hz<br />

Power: 2,60kVa<br />

Fuse: 20A<br />

Pre-Setting<br />

The unit already has programs of<br />

exposure times for each combination,<br />

which can be adjusted according to<br />

the needs of the professional.<br />

Functions:<br />

Setting the exposure times;<br />

Choosing the completion of radiography<br />

on film or digital sensor;<br />

Setting the dental element;<br />

Selecting the age group.<br />

<strong>KaVo</strong> Headoffice<br />

Rua Chapecó, 86 - Saguaçu<br />

CEP 89221-040 - Joinville / SC<br />

Tel.: (47) 3451.0100 | Fax.: (47) 3451.0214<br />

E-mail: falecom@kavo.com<br />

<strong>KaVo</strong> 70 kVp X-<strong>Ray</strong><br />

Fixed Pedestal<br />

Composed of column fixed to the floor with<br />

articulated pantographic arm. Optional rotating arm<br />

in measures 510 mm or 760 mm or 1010 mm.<br />

2 e 3<br />

Selection of<br />

<strong>Dental</strong> Element<br />

1<br />

Patient Selection<br />

Child or Adult<br />

<strong>KaVo</strong> São Paulo Innovation Center<br />

Alameda dos Aicás, 527 - Moema<br />

CEP 04086-001 - São Paulo / SP<br />

Tel.: (11) 3323.0500 | Fax.: (11) 3323.0505<br />

E-mail: saopaulo@kavo.com<br />

| ALWAYS FOR YOU<br />

7<br />

4<br />

Select Bite<br />

Select Film Image<br />

or Digital Image<br />

5 e 6<br />

Selection of<br />

<strong>Dental</strong> Element<br />

<strong>KaVo</strong> Distrito Federal Innovation Center<br />

Edifício Brasília Rádio Center SRTN - Quadra 702<br />

Conjunto P - Asa Norte - Loja 3<br />

CEP 70719-900 - Brasília / DF<br />

Tel.: (61) 3326.3995 | Fax.: (61) 3327.7653<br />

E-mail: distritofederal@kavo.com<br />

Iimages merely illustrative. The technical characteristics listed in this brochure may change without notice. PRINTED FEB. 2010.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!