2. Technical data<br />
Housing<br />
Material: ABS<br />
Design: Dust-tight, max. 3x M32/M20 possible,<br />
ATEX Ex II 3D T60°C<br />
Protection class: IP 65<br />
Operating<br />
temperature:<br />
.<br />
0 - 50 °C<br />
Climatic category: KWF acc. DIN 400040<br />
<strong>Control</strong> lamp<br />
(≤ 75 % relative humidity,<br />
no condensation allowed)<br />
Operation: LED green<br />
Cleaning: LED yellow<br />
Fault: LED red<br />
Valve display: LED red<br />
Alarm threshold: LED red<br />
Electrical data<br />
Electrical<br />
connection:<br />
Terminal strip 2.5 mm²/valve 1<br />
Voltage (primary): DC 24 V, AC 230 V/50-60 Hz<br />
Tolerance: ± 10 %<br />
Power: 42 W/30 VA<br />
Mains fuse: 3.15 A time-lag/0.315 A time-lag<br />
Valve outputs: 12 (extendable to 24)<br />
Valve voltage: DC 24 V<br />
Tolerance: ± 10 %<br />
Valve current: 1 A (for pulse time ≤ 1 s and<br />
interval time ≥ pulse time, otherwise 0.5 A)<br />
Relay outputs: Pin wiring DC 24 V/0.3 A, AC 250/5 A<br />
(Version with 2<br />
output ralays)<br />
1 change-over contact for operating/fault mes-<br />
.<br />
sage<br />
(fail-safe circuit)<br />
1 normaly open for cleaning message<br />
Inputs: Start or dp input<br />
Enable (contact closed)/Stop (contact open)<br />
Technical data is subject to change without notice!<br />
3. Order numbers<br />
Instant cleaning<br />
Fault acknowledgement (button)<br />
dp switch (optional)<br />
Order number Type designation<br />
79743071 <strong>MFS</strong>-<strong>05</strong> DC 24 V, standard<br />
79743477 <strong>MFS</strong>-<strong>05</strong> DC 24 V, 2 relay outputs<br />
79743<strong>05</strong>5 <strong>MFS</strong>-<strong>05</strong> AC 230 V, 50 - 60 Hz, standard<br />
79742974 <strong>MFS</strong>-<strong>05</strong> AC 230 V, 50 - 60 Hz, 2 relay outputs<br />
<strong>Control</strong> <strong>MFS</strong>-<strong>05</strong> 2