30.04.2013 Views

IVS-300 Application Note - santec

IVS-300 Application Note - santec

IVS-300 Application Note - santec

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

A new dimension in imaging<br />

<strong>IVS</strong>-<strong>300</strong><br />

SANTEC CORPORATION<br />

2011 Volume 1.0


<strong>IVS</strong>-<strong>300</strong> products line up<br />

1<br />

Hardware Software<br />

<strong>IVS</strong>-<strong>300</strong><br />

Select the Probe type<br />

Mouse type Long neck type<br />

Grip type<br />

A New Dimension in Imaging<br />

Inner Vision<br />

OCT Measurement and Imaging<br />

2D Analysis<br />

OCT Viewer<br />

2D Analysis / 3D Modeling<br />

Video Development (Option)<br />

Continuing its leadership in innovation in the Swept Source Optical Coherence Tomography (SS_OCT) market,<br />

Santec introduces the latest generation of SS-OCT console, the <strong>IVS</strong>-<strong>300</strong>. The <strong>IVS</strong>-<strong>300</strong> combines highly integrated<br />

all-in-one design with intuitive ease-of-use to deliver advanced imaging capabilities straight out of the box. With<br />

cutting edge features, functions and benefits the <strong>IVS</strong>-<strong>300</strong> empowers clinicians and researchers to effectively<br />

image and measure a range of parameters with the high sensitivity associated with the swept source OCT<br />

technique.<br />

Functions Include:<br />

Real-Time B-Scan Imaging: Video frame rate 2-D image slices.<br />

3-D image capture: Process 3-D image in a couple of seconds and export to the bundled 3D viewer.<br />

Thickness measurement function: Measures the thickness of layered structures with sub-micron precision.<br />

Surface profiling: Accurate surface or contour mapping, distortion-free, 3-D image.<br />

Cross-polarization Imaging: Enhance stability and contrast of image quality.


Sample data<br />

Finger<br />

Tooth with resin<br />

Composite resin filling<br />

Strawberry<br />

caries<br />

Enamel<br />

Dentin<br />

OCT-data(2D-Slice)<br />

Standard Type Probe<br />

(Non-Cross polarization)<br />

gum<br />

OCT-data<br />

epidermis<br />

Composite resin filling<br />

dermis<br />

caries<br />

Enamel<br />

Dentin<br />

OCT-data(2D-Slice)<br />

Cross Polarization Type Probe<br />

OCT-data(3D-Image) OCT-data(2D-Slice)<br />

SANTEC CORPORATION<br />

2D-Slice<br />

Stratum corneum<br />

Sweat gland<br />

OCT-data(2D-Slice)<br />

6


Contact information<br />

www.<strong>santec</strong>.com<br />

SANTEC CORPORATION<br />

5823 Ohkusa-Nenjyozaka, Komaki, Aichi 485-0802, Japan Tel. +81-568-79-1959 Fax +81-568-79-1718 E-Mail: sales@<strong>santec</strong>-net.co.jp<br />

SANTEC U.S.A. CORPORATION<br />

433 Hackensack Ave., Hackensack, NJ 07601, U.S.A. Toll Free +1-800-726-8321 (<strong>santec</strong>-1) Tel. +1-201-488-5505 Fax +1-201-488-7702 E-Mail: sales@<strong>santec</strong>.com<br />

SANTEC EUROPE LIMITED<br />

Magdalen Centre, Robert Robinson Ave., The Oxford Science Park, Oxford OX4 4GA, U.K. Tel. +44-1865-784960 Fax +44-1865-784961 E-Mail: sales@<strong>santec</strong>.co.uk<br />

SANTEC (SHANGHAI) Co., Ltd<br />

No.800 Zhangyang Road Changhang Tower, Pudong District, Shanghai 200122 China Tel. +86-21-58361261, +86-21-58361262 Fax +86-21-58361263<br />

E-Mail: sales@<strong>santec</strong>.com. cn<br />

2010 © SANTEC CORPORATION Santec reserves the right to make changes to equipment design, components or specifications without notice.<br />

<strong>IVS</strong>-<strong>300</strong> application note 2011-E / Volume.1.0 201108-A4-DO-MT-print

Hooray! Your file is uploaded and ready to be published.