02.10.2012 Views

EN-NP100-12R-01 • June - Accu-Profi

EN-NP100-12R-01 • June - Accu-Profi

EN-NP100-12R-01 • June - Accu-Profi

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Specifications<br />

<strong>•</strong> NOMINAL VOLTAGE: 12V<br />

<strong>•</strong> NOMINAL CAPACITY:<br />

20 hr. rate of 5.0A to 10.5V 100.0Ah<br />

10 hr. rate of 9.0A to 10.5V 90.0Ah<br />

5 hr. rate of 16.0A to 10.2V 80.0Ah<br />

1 hr. rate of 60.0A to 9.60V 60.0Ah<br />

<strong>•</strong> WEIGHT (approx.): 68 pounds (30.8kgs)<br />

<strong>•</strong> <strong>EN</strong>ERGY D<strong>EN</strong>SITY (20 hr. rate):<br />

1.62 WH/cubic inch (99.4 WH/liter)<br />

<strong>•</strong> SPECIFIC <strong>EN</strong>ERGY (20 hr. rate):<br />

17.6 WH/pound (38.9 WH/kg)<br />

<strong>•</strong> INTERNAL RESISTANCE OF CHARGED<br />

BATTERY:<br />

6.5 milliohms (approx.)<br />

<strong>•</strong> MAXIMUM DISCHARGE CURR<strong>EN</strong>T<br />

WITH STANDARD TERMINALS:<br />

150 amperes<br />

<strong>•</strong> MAXIMUM SHORT-DURATION<br />

DISCHARGE CURR<strong>EN</strong>T:<br />

500 amperes<br />

<strong>•</strong> OPERATING TEMPERATURE RANGE:<br />

CHARGE 5 0 F to 122 0 F<br />

(-15 0 C to 50 0 C)<br />

DISCHARGE -4 0 F to 140 0 F<br />

(-20 0 C to 60 0 C)<br />

<strong>•</strong> CHARGE RET<strong>EN</strong>TION (shelf life)<br />

at 68˚F (20˚C):<br />

1 month 97%<br />

3 months 91%<br />

6 months 85%<br />

<strong>•</strong> LIFE EXPECTANCY:<br />

STANDBY USE 3 to 5 years<br />

CYCLE USE (approx.):<br />

100% depth of discharge 250 cycles<br />

50% depth of discharge 550 cycles<br />

30% depth of discharge 1200 cycles<br />

<strong>•</strong> SEALED CONSTRUCTION:<br />

Can be operated in any position<br />

without leakage.<br />

<strong>•</strong> STANDARD TERMINAL:<br />

Receptacle terminal<br />

<strong>•</strong> HOUSING MATERIAL: PP Resin<br />

<strong>•</strong> OPTIONAL:<br />

Container and cover made from<br />

Flame Retardant PP<br />

(UL94-V0/L.O.I.>28%)<br />

Terminal<br />

DIM<strong>EN</strong>SIONS: MM (INCHES)<br />

Dimensions<br />

12.95 (329.0)<br />

DIM<strong>EN</strong>SIONS: INCHES (MM)<br />

NP<br />

<strong>NP100</strong>-<strong>12R</strong><br />

<strong>NP100</strong>-<strong>12R</strong>FR<br />

Sealed Rechargeable<br />

Lead-Acid Battery<br />

12V, 100Ah<br />

6.77 (172.0)<br />

M6<br />

Φ20 (0.79)<br />

UL listing pending - File No MH14328<br />

Publication No: <strong>EN</strong>-<strong>NP100</strong>-<strong>12R</strong>-<strong>01</strong> <strong>•</strong> <strong>June</strong> 2005<br />

8.43 (214.0)


REMAINING CAPACITY<br />

PERC<strong>EN</strong>TAGE OF CAPACITY AVAILABLE<br />

TERMINAL VOLTAGE<br />

SELF DISCHARGE CHARACTERISTICS<br />

(%)<br />

100<br />

75<br />

50<br />

25<br />

0<br />

(AH%)<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

DISCHARGE CHARACTERISTIC<br />

CURVES AT 25 0 C (77 0 F)<br />

CYCLE SERVICE LIFE IN RELATION<br />

TO DEPTH OF DISCHARGE<br />

EnerSys<br />

P.O. Box 14145<br />

Reading, PA 19612-4145<br />

USA<br />

Tel:+1-610-208-1991<br />

+1-800-538-3627<br />

EnerSys EMEA<br />

Brussels, Belgium<br />

Tel:+32 (0)2 247 94 47<br />

EnerSys Asia<br />

Guandong, China<br />

Tel:+86 755 689 9220<br />

(V)<br />

14.0<br />

13.0<br />

12.0<br />

11.0<br />

OP<strong>EN</strong> CIRCUIT VOLTAGE<br />

VS REMAINING CAPACITY<br />

10.0<br />

3 6 9 12 15 18 0 20 40 60 80 100<br />

STORAGE TIME (MONTHS)<br />

TESTING CONDITIONS: DISCHARGE CURR<strong>EN</strong>T: 0.17C AMP. (F.V. 1.7V/CELL)<br />

CHARGING CURR<strong>EN</strong>T: 0.09C AMP.<br />

CHARGING VOLUME: 125% OF DISCHARGED CAPACITY<br />

AMBI<strong>EN</strong>T TEMPERATURE: 20 0 C TO 25 0 C (68 0 F TO 77 0 F)<br />

100% D.O.D.<br />

50% D.O.D.<br />

40 0 C (104 0 F)<br />

NUMBER OF CYCLES<br />

30 0 C (86 0 F)<br />

20 0 C (68 0 F)<br />

30% DEPTH OF DISCHARGE<br />

200 400 600 800 1000 1200 1400<br />

OP<strong>EN</strong> CIRCUIT VOLTAGE<br />

PERC<strong>EN</strong>TAGE OF CAPACITY AVAILABLE<br />

(AH%)<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

0<br />

When the battery will be used by current in excess of 3C, consult with EnerSys prior to use.<br />

CHARGING METHODS (At 20˚C) Cycle use: Maximum charging current 0.25C<br />

Charging voltage 14.4 to 15.0V<br />

Standby use: Float charging voltage 13.50 to 13.80V<br />

CAUTION <strong>•</strong>Avoid short circuit<br />

<strong>•</strong>Do not charge in a sealed container.<br />

www.enersys.com<br />

PERC<strong>EN</strong>TAGE OF CAPACITY AVAILABLE<br />

TEMPERATURE EFFECTS IN RELATION<br />

TO BATTERY CAPACITY<br />

REMAINING CAPACITY (%)<br />

FLOAT SERVICE LIFE<br />

TESTING CONDITIONS: FLOATING VOLTAGE 2.25 TO 2.30V/CELL<br />

AMBI<strong>EN</strong>T TEMPERATURE: 20 0 C TO 22 0 C (64 0 F TO 72 0 F)<br />

1 2 3 4 5 5.5<br />

LIFE (YEARS)<br />

Represented by:<br />

AT 25 0 C (77 0 F)<br />

© 2005 EnerSys. All rights reserved.<br />

Trademarks are the property of EnerSys and its<br />

affiliates unless otherwise noted.<br />

Publication No: <strong>EN</strong>-<strong>NP100</strong>-<strong>12R</strong>-<strong>01</strong> <strong>•</strong> <strong>June</strong> 2005 Subject to revisions without prior notice. E.&O.E.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!