DESCRIPTION AND<br />
MATERIAL<br />
CABLE<br />
USES<br />
GUIDELINES<br />
Technical Bulletin 85 01 1-800-327-0971<br />
MINIATURE HIGH DENSITY SERIES<br />
© 2009 <strong>Teledyne</strong> <strong>Impulse</strong><br />
TELEDYNE<br />
IMPULSE<br />
316 stainless steel passivated per QQ-P-35 Type VI with naval<br />
bronze engaging nut.<br />
Special alloys are available upon request (contact factory).<br />
Contains a removable glass reinforced epoxy insert.<br />
(Except for MHDG series and CCP's)<br />
Up to 61 contacts.<br />
Up to 600 VDC.<br />
10,000 PSI in mated condition (higher pressure rating available<br />
using special alloy metal shell; please contact factory).<br />
Bulkhead connector design open face pressure rated to 5,000 psi.<br />
MHD-CCR/CCP connectors can be overmolded with polyurethane.<br />
Contacts are gold plated per MIL-G-45204.<br />
Connector's amperage and voltage may be limited by the<br />
amperage and voltage ratings of the cable to which the con-<br />
nector is molded.<br />
This series is not molded to cable unless specified at the time<br />
of order.<br />
Signal telemetry.<br />
Hazardous environment.<br />
FCR is mounted by use of four equally spaced bolts around the<br />
flange surface.<br />
FCR is used in place of the BCR when the use of a bulkhead<br />
nut and washer is impractical.<br />
For all open face pressures above 5,000 PSI the BCR, FCR must<br />
be back potted (please contact the factory).<br />
The CCR is used in a variety of environments where<br />
cable to cable termination is necessary.<br />
Mounting torque should not exceed 150 in lbs. for this series.<br />
All mounting surfaces require a 32 finish.<br />
Align indexes.<br />
Keep o-ring grooves clean.<br />
Avoid o-ring cuts and nicks.<br />
Lubricate o-rings with Dow Corning #111 Valve Lubricant or<br />
equivalent.<br />
Replace o-rings when re-using connectors.<br />
Avoid contact with noxious solvents.<br />
Elastomers can be seriously degraded if exposed to direct<br />
sunlight or high ozone levels for extended periods of time.<br />
rev 0703
MHDG<br />
3.25<br />
2.13<br />
1.02<br />
.38<br />
STAINLESS<br />
STEEL<br />
ALIGNMENT<br />
KEY<br />
~<br />
MHDG-CCP<br />
1.00 DIA<br />
MHDG-BCR<br />
MINIATURE HIGH DENSITY SERIES<br />
2.35 STAINLESS<br />
STEEL<br />
.69 DIA<br />
NEOPRENE/<br />
POLYURETHANE<br />
OVERMOLD<br />
MHDG-CCP-RA<br />
RETAINING RING<br />
5100-68H<br />
O-RING<br />
2-017<br />
(SEE DETAIL A)<br />
O-RING<br />
2-016<br />
STAINLESS<br />
STEEL<br />
O-RING<br />
2-015<br />
.94 HEX<br />
O-RING<br />
5-254<br />
2.6<br />
MATED<br />
LENGTH<br />
9/16-18 UNF-2A<br />
3.8<br />
MATED<br />
LENGTH<br />
DELRIN<br />
WASHER<br />
NAVAL<br />
BRONZE<br />
STAINLESS<br />
STEEL<br />
TELEDYNE<br />
IMPULSE<br />
Technical Bulletin 85 20 1-800-327-0971 © 2009 <strong>Teledyne</strong> <strong>Impulse</strong><br />
rev 0105<br />
.56<br />
POLYURETHANE<br />
OVERMOLD<br />
DETAIL A<br />
~<br />
MHDG-CCP<br />
~<br />
MHDG-CCR<br />
~<br />
*****<br />
1.51<br />
4.14
MHDG<br />
.840<br />
1.12 TYP<br />
4X .125 DIA THRU<br />
STAINLESS<br />
STEEL<br />
.185<br />
O-RING 5-254<br />
O-RING 5-566<br />
.90 TYP<br />
MHDG-FCR<br />
**<br />
.576 DIA<br />
MOUNTING TORQUE<br />
FOR MHDG-BCR<br />
DUMMY PLUG FOR<br />
MHDG-BCR/FCR/CCR<br />
.375<br />
NOTE: CCP is not terminated to cable unless specified.<br />
* Please specify number of contacts.<br />
MINIATURE HIGH DENSITY SERIES<br />
2#14<br />
600VDC<br />
2#16<br />
5#20<br />
** Internal assembly same as MHDG-BCR (facing page).<br />
*** Blind tapped hole not to penetrate bulkhead, minimum full thread depth 2 times bolt diameter.<br />
32<br />
CONTACT<br />
CONFIGURATION<br />
(BCR FACE VIEW)<br />
8#20<br />
2#20 2#20<br />
4#22<br />
12#22 13#22<br />
300VDC 300VDC 300VDC<br />
MOUNTING INSTRUCTIONS<br />
.90<br />
15° LEAD IN<br />
CHAMFER<br />
32<br />
.580<br />
.578<br />
**** Oil filled version available. See section 86.<br />
***** O-Ring installation tool available - Contact factory for further details.<br />
1<br />
5<br />
6<br />
3#16 2#14<br />
2#16<br />
5#16<br />
600VDC 300VDC 300VDC<br />
3#16<br />
5#20<br />
32<br />
DIA<br />
MATED PRESSURE RATING (psi)<br />
DUMMY PLUG FOR<br />
MHDG-CCP<br />
9#20<br />
SEE<br />
CHART<br />
***<br />
10#20<br />
300VDC 300VDC 300VDC 300VDC<br />
8<br />
7<br />
12<br />
6<br />
5<br />
7<br />
4<br />
not to exceed<br />
150 in lbs<br />
MHDG-SCP<br />
1<br />
1<br />
9 2<br />
10<br />
11 3<br />
4<br />
2<br />
2<br />
3<br />
6<br />
10<br />
1<br />
3 2<br />
5<br />
7 1<br />
11<br />
8<br />
4<br />
1<br />
14 12<br />
2<br />
3<br />
2<br />
3<br />
9<br />
4<br />
8 13 5<br />
7 6<br />
4<br />
7<br />
1<br />
8 2<br />
6<br />
5<br />
1<br />
3<br />
9<br />
2<br />
4<br />
3<br />
1<br />
10 2<br />
11<br />
15 12 3<br />
9<br />
8<br />
14<br />
13 4<br />
7<br />
6<br />
5<br />
5<br />
7<br />
6<br />
10,000<br />
4<br />
8<br />
5<br />
10<br />
MHDG-SCR<br />
1<br />
9<br />
1<br />
4<br />
3<br />
2<br />
2<br />
3<br />
6 7<br />
5<br />
14<br />
4<br />
13<br />
3 12<br />
8<br />
15<br />
9<br />
16<br />
10<br />
2<br />
1<br />
11<br />
1#20<br />
15#22<br />
300VDC<br />
TELEDYNE<br />
IMPULSE<br />
Technical Bulletin 85 21 1-800-327-0971 © 2009 <strong>Teledyne</strong> <strong>Impulse</strong><br />
rev 1006
MHD<br />
CONNECTOR SIZE<br />
A O-RING<br />
B ENGAGING NUT<br />
C O-RING<br />
D DELRIN WASHER(2X)<br />
E RETAINING RING<br />
F DIA<br />
G<br />
H I DIA<br />
I<br />
G<br />
MATED<br />
PRESSURE RATING (psi)<br />
I<br />
MINIATURE HIGH DENSITY SERIES<br />
SCP<br />
F<br />
SCR<br />
H<br />
MHDG MHDL<br />
MHDM MHDO<br />
2-016 2-018 2-020 2-023<br />
605165 605280 602004 605450<br />
2-017 R00787-<br />
039-070<br />
2-022 2-024<br />
605101 605273 602005 605430<br />
5100-68 5100-75 5100-100 5100-112<br />
.69 .75 1.00 1.12<br />
1.05 .95 .97<br />
1.25<br />
1.00<br />
1.25<br />
1.43<br />
1.62<br />
1.00 .90 .87<br />
1.25<br />
10,000 10,000 10,000 10,000<br />
E<br />
D<br />
C<br />
B<br />
A<br />
MHDR<br />
2-029<br />
602261<br />
2-029<br />
602220<br />
5100-156<br />
1.56<br />
1.45<br />
2.00<br />
1.45<br />
10,000<br />
TELEDYNE<br />
IMPULSE<br />
Technical Bulletin 85 65 1-800-327-0971 © 2009 <strong>Teledyne</strong> <strong>Impulse</strong><br />
rev 1006