3-Way Temperature Control Valve - Amot
3-Way Temperature Control Valve - Amot
3-Way Temperature Control Valve - Amot
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
3-<strong>Way</strong> <strong>Temperature</strong> <strong>Control</strong> <strong>Valve</strong> - Model G, Version G<br />
Overview of <strong>Valve</strong> Body<br />
Specification<br />
<strong>Valve</strong> Body<br />
Flow to: 720m 3 /hr 3,170 US gpm<br />
For valves with higher flow rates see datasheet GEF_GPD_Temp_<strong>Control</strong>_<strong>Valve</strong><br />
Sizes: Standard flow High flow<br />
Datasheet_GG_Temp_<strong>Control</strong>_<strong>Valve</strong>_0212_rev7<br />
80mm - 200mm (3” - 8”) 80mm - 200mm (3” - 8”)<br />
For 50 mm (2”) and for 350 mm (14”) and above see Datasheet<br />
GEF_GPD_Temp_<strong>Control</strong>_<strong>Valve</strong> for data<br />
Body/rotor materials: Bronze For seawater, shock resistance, or<br />
magnetic permeability<br />
Seal material: Flourocarbon (Viton, FKM)<br />
Ductile iron High performance iron, for fresh<br />
water, lubricating oils<br />
Steel For high strength and high pressure<br />
ratings<br />
Stainless steel Corrosive and special applications<br />
Flanges: EN 1092, ASME and JIS standards.<br />
Maximum internal Ductile iron or bronze 10 bar (145 psi)<br />
valve pressure: Steel and stainless steel 16 bar (232 psi)<br />
Maximum temperature 100°C (212°F)<br />
of fluid:<br />
Vibration: Exceeds the requirements of Lloyd’s Register Type Approval System,<br />
Test Specification Number 1, 2002, Vibration Test 2.<br />
For both electric and pneumatic:<br />
Frequency<br />
range<br />
Key features and benefits<br />
l Lightweight and compact<br />
Displacement Acceleration Lloyd’s<br />
5 - 25 Hz +/- 1.6mm +/- 1.6mm<br />
25 - 100 Hz +/- 5.0g (49 m/s 2 ) +/- 4.0g (39 m/s 2 )<br />
100 - 300 Hz +/- 1.0g (9.81 m/s 2 ) 90<br />
minute<br />
l Configurable ports - allowing flexibility on<br />
installation<br />
l Low pressure drop - enables savings on<br />
either valve or pump size<br />
l High accuracy providing better temperature<br />
control<br />
No requirement<br />
page 6