19.05.2013 Views

MOULDED CASE CIRCUIT BREAKER

MOULDED CASE CIRCUIT BREAKER

MOULDED CASE CIRCUIT BREAKER

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>MOULDED</strong> <strong>CASE</strong><br />

<strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

C<br />

People Electric<br />

Appliance serves for people.<br />

• ISO9001<br />

ISO14001 OHSAS18001


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

A C-01<br />

RDM1-63L 3P<br />

RDM1-225L 3P<br />

RDM1-400 3P<br />

RDM1 <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

APPLICATION<br />

RDM1 series of moulded case circuit breaker is a new type product developed and manufactured<br />

by adopting international advanced technology. It is supplied with rated insulation voltage 800V<br />

and used for circuit of AC50Hz, rated operating voltage AC 400V or below rated operation current<br />

up to 800A for infrequent changing over and starting of the motors. Equipped w ith the protection<br />

devices for over-current, short circuit and undervoltage, the product is capable of preventing<br />

damage of circuits and supplying units The product conforms to IEC60947-2.<br />

SPECIFICATION<br />

Type<br />

RDM1-63L<br />

RDM1-63M<br />

RDM1-100C<br />

RDM1-100L<br />

RDM1-100M<br />

RDM1-100H<br />

RDM1-225C<br />

RDM1-225L<br />

RDM1-225M<br />

RDM1-225H<br />

RDM1-400C<br />

RDM1-400L<br />

RDM1-400M<br />

RDM1-630C<br />

RDM1-630L<br />

RDM1-630M<br />

RDM1-630H<br />

RDM1-800M<br />

RDM1-800H<br />

Rated<br />

current<br />

(A)<br />

6,10,16,20,<br />

25,32,40,<br />

50,63<br />

10,16,20,<br />

25,32,40,<br />

50,63,80,<br />

100<br />

100,125<br />

160,180<br />

200,<br />

225,250<br />

315,350<br />

400<br />

400<br />

500<br />

630<br />

630,700<br />

800<br />

Number<br />

of<br />

Poles<br />

3P,<br />

4P<br />

Rated<br />

insulation<br />

voltage<br />

(V)<br />

ACCESSORIES FOR MCCB<br />

Rated<br />

operating<br />

voltage<br />

(V)<br />

660V 380V<br />

Alarm contact<br />

Arcingover<br />

distance<br />

(mm)<br />

0<br />

0<br />

0<br />

0( 50)<br />

0( 50)<br />

0( 50)<br />

50<br />

50<br />

50<br />

50<br />

50<br />

50<br />

50<br />

100<br />

100<br />

100<br />

100<br />

100<br />

100<br />

Ultimate Service<br />

short short<br />

circuit circuit<br />

breaking breaking<br />

capacity capacity<br />

(KA) (KA)<br />

25<br />

50<br />

25<br />

35<br />

50<br />

85<br />

25<br />

35<br />

50<br />

85<br />

35<br />

50<br />

65<br />

35<br />

50<br />

65<br />

100<br />

65<br />

100<br />

18<br />

35<br />

18<br />

22<br />

35<br />

50<br />

18<br />

22<br />

35<br />

50<br />

25<br />

35<br />

42<br />

25<br />

35<br />

42<br />

65<br />

42<br />

65<br />

Operation<br />

performance<br />

ON OFF<br />

1500 8500<br />

1000 7000<br />

1000 4000<br />

Under voltage release<br />

Manual operation Auxiliary contact Shunt release


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

RDM11-100N<br />

RDM11-100N 3P<br />

RDM11-250N<br />

RDM11-250N 4P<br />

RDM11-630N 3P<br />

A C-02<br />

RDM11 <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

APPLICATION<br />

RDM11 moulded case circuit breaker is one of the most advanced type breakers in the world,<br />

which adopts international advanced design and manufacture technology. They are suitable for short<br />

circuit and overload protection for circuit of AC 690V 50/60Hz, rated current from 12.5A to 630A.<br />

It takes protective effect when mouse cage motors non-frequent start, breaking off working<br />

and protecting overload, short circuit and lacking voltage.<br />

TRIPPING CHARACTERISTICS OF MCCB<br />

Rated current of<br />

release(A)<br />

In 63<br />

63 In 100<br />

100 In 630<br />

Rated current of<br />

release(A)<br />

12.5 In 400<br />

SPECIFICATION<br />

Thermodynamic release (ambient temp+40 )<br />

1.05In(cold state)<br />

1.30In(heat state)<br />

operative time (h)<br />

operative time (h)<br />

1<br />

1<br />

2<br />

2<br />

2<br />

2<br />

1.0In<br />

(cold state)<br />

operative<br />

time (h)<br />

Type<br />

Rated<br />

current<br />

(A)<br />

Poles<br />

RDM11-100D<br />

RDM11-100N<br />

RDM11-100H<br />

RDM11-100L<br />

RDM11-160D<br />

RDM11-160N<br />

RDM11-160H<br />

RDM11-160L<br />

RDM11-250D<br />

RDM11-250N<br />

RDM11-250H<br />

RDM11-250L<br />

RDM11-400D<br />

RDM11-400N<br />

RDM11-400H<br />

RDM11-400L<br />

RDM11-630D<br />

RDM11-630N<br />

RDM11-630H<br />

RDM11-630L<br />

RDM11-1250D<br />

RDM11-1250N<br />

RDM11-1250H<br />

RDM11-1250L<br />

RDM11-1600D<br />

RDM11-1600N<br />

RDM11-1600H<br />

RDM11-1600L<br />

12.5,16,<br />

20,25,32,<br />

40,50,63,<br />

80,100<br />

16,20,25,<br />

32,40,50,<br />

63,80,100,<br />

125,160<br />

160,180,<br />

200,225,<br />

250<br />

200,225,<br />

250,300,<br />

315,400<br />

315,350,<br />

400,500,<br />

600,630<br />

630,700<br />

800,1000,<br />

1250<br />

800,1000,<br />

1250,<br />

1600<br />

2<br />

Thermodynamic release (ambient temp+40 )<br />

1.20In<br />

(heat state)<br />

operative<br />

time (h)<br />

Rated<br />

insulating<br />

voltage<br />

(V)<br />

1.50In<br />

(heat state)<br />

operative<br />

time (h)<br />

2 4min<br />

Rated<br />

operating<br />

voltage<br />

(V)<br />

Arcing<br />

over<br />

distance<br />

(mm)<br />

3,4 950 690 0<br />

7.20In(cold<br />

state)<br />

operative<br />

time (h)<br />

2S Tp 10S<br />

Ultimate<br />

short<br />

circuit<br />

breaker<br />

capacit<br />

18<br />

25<br />

70<br />

150<br />

25<br />

36<br />

70<br />

150<br />

25<br />

36<br />

70<br />

150<br />

35<br />

45<br />

70<br />

150<br />

35<br />

45<br />

70<br />

150<br />

50<br />

65<br />

85<br />

160<br />

50<br />

65<br />

85<br />

160<br />

Operational current<br />

of magnetic<br />

release(A)<br />

10In 20%<br />

10In 20%<br />

5-10In 20%<br />

Operational current<br />

of magnetic<br />

release(A)<br />

Servies<br />

short<br />

circuit<br />

breaker<br />

capacity<br />

18<br />

25<br />

70<br />

150<br />

25<br />

36<br />

70<br />

150<br />

25<br />

36<br />

70<br />

150<br />

35<br />

45<br />

70<br />

150<br />

35<br />

45<br />

70<br />

150<br />

50<br />

65<br />

85<br />

160<br />

50<br />

65<br />

85<br />

160<br />

12In 20%<br />

Operating<br />

performance<br />

(times)<br />

1500 8500<br />

1500 7000<br />

1000 7000<br />

1000 4000<br />

1000 4000<br />

500,2500<br />

500,2500


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

PNE-100 2P<br />

PNE-100 3P<br />

PNE-250 3P<br />

A C-03<br />

PNE-100<br />

PNE-250<br />

PNE <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

APPLICATION<br />

PNE moulded case circuit break er is one of the most advanced type breakers in the<br />

world, which ado pts international advanced design and manufactur technology. They are<br />

suitable for short circuit and overload protection for circuit of AC 690V 50/ 60Hz, rated current<br />

from 15A to 160A. Its rated insulation voltage is 690V. It can make and break the nonfrequen<br />

t circui t in the normal cond itio ns. It takes protective effect when mouse cage<br />

motors no n-fr equent starting or breaking off working and protecting overload, short<br />

circuit and lacking voltage. It complies with IEC60947-2.<br />

MAIN TECHNICAL SPECIFICATION<br />

Type<br />

Number of Poles<br />

Rated Current In(A)<br />

Rated Operating Voltage Ue(V) AC50/60Hz<br />

Rated Insulation Voltage Ui(V)<br />

Rated (kV)Uimp<br />

Breaking Capacity<br />

(kA ms)<br />

IEC60947-2<br />

Breaking Capacity(kA)<br />

(NEMA-ABI)(HIC)<br />

Mechanical Life<br />

Electrical Life<br />

Overload<br />

Current<br />

Protection(A)<br />

Dimensions(mm)<br />

L H D<br />

Icu AC<br />

Ics%Icu<br />

AC<br />

220/240V<br />

380V<br />

400<br />

220/240V<br />

380V<br />

400V<br />

240V<br />

480V<br />

Hot protection<br />

Magnetism protection<br />

PNE 60E PNE 100F PNE 100H PNE 250<br />

3 3 3 3<br />

15,20,25,<br />

30,40,50,<br />

60<br />

500<br />

500<br />

6<br />

10<br />

7.5<br />

7.5<br />

25%<br />

25%<br />

25%<br />

-<br />

-<br />

8.500<br />

4.000<br />

Fixed<br />

Fixed<br />

75 130<br />

60<br />

15,20,25,<br />

30,40,50,<br />

60,75,80,<br />

100<br />

500<br />

500<br />

6<br />

25<br />

10<br />

7.5<br />

25%<br />

25%<br />

25%<br />

-<br />

-<br />

8.500<br />

4.000<br />

Fixed<br />

Fixed<br />

75 130<br />

60<br />

15,20,25,<br />

30,40,50,<br />

60,75,80,<br />

100<br />

500<br />

500<br />

6<br />

50<br />

30<br />

20<br />

25%<br />

25%<br />

25%<br />

25<br />

10<br />

8.500<br />

4.000<br />

Fixed<br />

Fixed<br />

75 130<br />

60<br />

125,160<br />

225,250<br />

500<br />

500<br />

6<br />

85<br />

18<br />

15<br />

50%<br />

50%<br />

50%<br />

25<br />

10<br />

8.500<br />

4.000<br />

Fixed<br />

Fixed<br />

105 165<br />

65


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

RDM8 125-CW<br />

PT-125<br />

PT-250<br />

RDM8 125-CW<br />

RDM8 125-CW<br />

RDM8 250-CW<br />

A C-05<br />

PT <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

APPLICATION<br />

PT Moulded case circuit breaker is suitable for circuit AC 50Hz/60Hz, rated voltage up toAC 660V,<br />

rated operating current to 630A. It features normal structure, reliable performance, complete<br />

accessories & high breaking capacity, used for power dis tribution and protecting the circu it and<br />

electrical equipment against overload and short-circuit. It complies with standard of IEC947-2.<br />

TRIPPING CHARACTERISTICS OF MCCB<br />

Rated current of<br />

release (A)<br />

In 63<br />

63 In 250<br />

25 In 800<br />

Type<br />

RDM8(CW)-100<br />

Thermodynamic release(ambient temp+40 )<br />

1.05In (cold state)<br />

operative time (h)<br />

1<br />

2<br />

2<br />

Rated current (A)<br />

15,20,30,40,50,60,75,100,125<br />

1.30In (heat state)<br />

operative time (h)<br />

1<br />

2<br />

2<br />

Pole number<br />

3 pole<br />

Rated operating<br />

voltage (V)<br />

Operational current<br />

of magnetic<br />

release(A)<br />

10-50In 20%<br />

10In 20%<br />

5-10In 20%<br />

RDM8-CW <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

RDM8-CW moulded case circuit breaker is available in three ranges, standard, highbreaking<br />

capacity. The performance of the RDM8-CW MCCB range is the result of ex tens ive design<br />

& development utilising AAD accredited test station. The current limiting action fo RDM8-CW<br />

MCCB provi des low va lues of let-through energy. Full information for this and time/current<br />

characteristic curves are both available on request to provide more information.<br />

Rated operating<br />

voltage (V)<br />

660V 380V, 660V<br />

RDM8(CW)-250 125,150,175,200,225,250 3 pole 660V 380V, 660V<br />

TRIPPING CHARACTERISTICS OF MCCB<br />

Rated current of<br />

release (A)<br />

In 63<br />

63 In 250<br />

25 In 800<br />

Thermodynamic release(ambient temp+40 )<br />

1.05In (cold state)<br />

operative time (h)<br />

1<br />

2<br />

2<br />

1.30In (heat state)<br />

operative time (h)<br />

1<br />

2<br />

2<br />

Operational current<br />

of magnetic<br />

release(A)<br />

10-50In 20%<br />

10In 20%<br />

5-10In 20%


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

RDM8 30-CS<br />

RDM8 30-CS 3P<br />

RDM8 100-CS<br />

RDM8 100-CS 3P<br />

RDM8 50-SS<br />

RDM8 50-SS 3P<br />

RDM8 250-SS<br />

RDM8 250-SS 3P<br />

A C-06<br />

RDM8-CS <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

APPLICATION<br />

RDM8-CS series Moulded Case Circuit Breaker is a kind of economic breaker, has the features as<br />

following, such as steady and reliable property, reasonable structure, beautiful style, small volume,<br />

etc. This breaker applies to the circuit with AC 50/60 Hz, r ated insulation voltage 660V, max.rated<br />

current 1250A as on-off operation, and take effect, it also can be used as unfrequent conversion of<br />

line and unfrequency.<br />

SPECIFICATION<br />

Type<br />

RDM8 30-CS<br />

RDM8 50-CS<br />

RDM8 60-CS<br />

RDM8 100-CS<br />

RDM8 250-CS<br />

RDM8 400-CS<br />

RDM8 630-CS<br />

RDM8 800-CS<br />

RDM8 1250-CS<br />

Pole<br />

Number<br />

(P)<br />

3<br />

2,3<br />

3<br />

2,3<br />

3<br />

3<br />

3<br />

3<br />

3<br />

Rated current(A)<br />

3,5,10,15,20,30<br />

10,15,20,30,40,50<br />

60<br />

60,70,100<br />

125,150,175,200,225,250<br />

250,300,350,400<br />

500,600,630<br />

600,700,800<br />

800,1000,1200,1250<br />

Rated<br />

current of<br />

frame(A)<br />

30<br />

50<br />

60<br />

100<br />

250<br />

400<br />

630<br />

800<br />

1250<br />

Rated ultimate<br />

breaking capacity<br />

(KA)<br />

1.5<br />

5/10<br />

5/10<br />

18/25<br />

18/35<br />

25/50<br />

35<br />

35<br />

85<br />

RDM8-SS <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

APPLICATION<br />

RDM8-SS series Moulded Case Circuit Breaker is a kind of economic breaker, has the features as<br />

following, such as steady and reliable property, reasonable structure, beautiful style, small volume,<br />

etc. This breaker applies to the circuit with AC50/60Hz, rated insulation voltoge 660V, max.rated<br />

current 1250A as on-off operation, and take effect, it also can be used as unfrequent conversion of<br />

line and unfrequency.<br />

SPECIFICATION<br />

Type<br />

RDM8 30-SS<br />

RDM8 50-SS<br />

RDM8 60-SS<br />

RDM8 100-SS<br />

RDM8 250-SS<br />

RDM8 400-SS<br />

RDM8 630-SS<br />

RDM8 800-SS<br />

Pole<br />

number<br />

2<br />

3<br />

3<br />

3<br />

3<br />

4<br />

3<br />

4<br />

3<br />

4<br />

3<br />

4<br />

3<br />

4<br />

Rated current<br />

(A)<br />

3,5,10,15,20,30<br />

10,20,30,40,50<br />

10,20,30,40,50,60<br />

60,75,100<br />

125,150,175,200,<br />

225,255<br />

250,300,350,400<br />

500,600,630<br />

600,700,800<br />

Breaking capacity(KA)<br />

AC(P1/P2)<br />

240 380 415 500 600 660<br />

5/5 5/2.5 2.5/1.5 2.5/1.0<br />

5/10<br />

5/10<br />

50/42<br />

50/42<br />

85/60<br />

85/60<br />

85/60<br />

10/7.5<br />

10/7.5<br />

30/20<br />

30/22<br />

50/35<br />

50/35<br />

50/35<br />

7.5/5<br />

7.5/5<br />

7.5/8<br />

25/15<br />

25/20<br />

50/30<br />

50/30<br />

7.5/5<br />

7.5/5<br />

15/10<br />

18/15<br />

35/25<br />

35/25<br />

35/25<br />

- -<br />

2.5/1.5<br />

2.5/1.5<br />

10/5<br />

15/10<br />

25/18<br />

25/18<br />

25/18<br />

-<br />

-<br />

5/2.5<br />

5/2.5<br />

15/10<br />

15/10<br />

15/10


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

RDM7 103B<br />

RDM7 103B<br />

(EA103B)<br />

RDM7 33B<br />

A C-07<br />

RDM7 33B<br />

(SA33B)<br />

RDM7 52B<br />

RDM7 52B<br />

(SA52B)<br />

RDM7(EA\SA) <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

APPLICATION<br />

The circuit breaker is suitable for industrial or commercial power and lighting circuit. Its rated<br />

working voltage is from 240V to 415V(AC 50Hz). It can be used to protect the circuit that overload<br />

or short circuit may take place and also for protecting the circuit which is not frequent in making<br />

break operation under normal conditions.<br />

SPECIFICATION<br />

Type Pole Rated current(A)<br />

RDM7 32<br />

RDM7 33<br />

RDM7 52<br />

RDM7 53<br />

RDM7 62<br />

RDM7 63<br />

RDM7 102<br />

RDM7 103<br />

RDM7 202<br />

RDM7 203<br />

RDM7 403<br />

2<br />

3<br />

2<br />

3<br />

2<br />

3<br />

2<br />

3<br />

2<br />

3<br />

3<br />

3,5,10,15,20,30<br />

3,5,10,15,20,30<br />

15,20,30,40,50<br />

15,20,30,40,50<br />

60<br />

60<br />

60,75,100<br />

60,75,100<br />

125,150,175,200,225<br />

125,150,175,200,225<br />

250,300,350,400<br />

Type Pole Rated current(A)<br />

RDM7 32<br />

RDM7 33<br />

RDM7 52<br />

RDM7 53<br />

RDM7 62<br />

RDM7 63<br />

RDM7 103<br />

RDM7 202<br />

RDM7 203<br />

RDM7 403<br />

2<br />

3<br />

2<br />

3<br />

2<br />

3<br />

3<br />

2<br />

3<br />

3<br />

3,5,10,15,20,30<br />

3,5,10,15,20,30<br />

15,20,30,40,50<br />

15,20,30,40,50<br />

60<br />

60<br />

15,20,30,40,50,60,75,100<br />

125,150,175,200,225<br />

125,150,175,200,225<br />

250,300,350,400<br />

Breaking<br />

capacity<br />

(KA)<br />

1.5<br />

1.5<br />

2.5<br />

2.5<br />

2.5<br />

2.5<br />

7.5<br />

7.5<br />

10<br />

10<br />

18<br />

Breaking<br />

capacity<br />

(KA)<br />

1.5<br />

1.5<br />

5<br />

5<br />

5<br />

5<br />

15<br />

18<br />

18<br />

22<br />

Rated voltage(V)<br />

415<br />

415<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

Rated voltage(V)<br />

660<br />

660<br />

660<br />

660<br />

660<br />

660<br />

660<br />

660<br />

660<br />

660


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

A C-08<br />

PABS-103b<br />

PABS-103b<br />

PABS-203b<br />

PABS-203b<br />

PABS-403b<br />

PABS-403b<br />

PABS-D <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

APPLICATION<br />

PABS-D series moulded case circuit breaker is suitable for industrial or commercial power and<br />

lighting with AC 50/60Hz, rated working voltage up to AC600V/DC 250V, rate d cu rrent up to<br />

1200A. It s a kind of economical breakers with the ch aracters of stable an d reli abl e f un ctio n,<br />

beautiful appearance, small size and line and infrequent starting motor. It can also be a ttached<br />

to install the accessories which have protection function for avoiding loss-voltage, under-voltage.<br />

The prod uct can inst all conn ection line with front board and back board, it also can be equipped<br />

hand-operating appar atus or mo tor-op erating apparatus to control in a remote distance.<br />

SPECIFICATION<br />

Rated current in (A) 40<br />

reference ambient temperature<br />

Number of poles<br />

Max rated service<br />

voltage Ui (V)<br />

Dimensions and<br />

mounting details<br />

Dimensions and mounting details<br />

Shopping fitting<br />

b<br />

bb<br />

aa<br />

a<br />

GB14048-2 AC<br />

(No symmetry value/<br />

symmetry value)<br />

DC<br />

IEC60947-2<br />

Icu<br />

AC<br />

Connection way<br />

c<br />

ca<br />

AC<br />

DC<br />

a<br />

b<br />

c<br />

ca<br />

bb<br />

aa<br />

500V 600V<br />

440V 480V<br />

380V<br />

220V 240V<br />

500V<br />

440V<br />

415V<br />

380V<br />

240V<br />

250V<br />

125V<br />

Alarming switch (AL)<br />

Auxiliary switch (AUX)<br />

Voltage release mounting (SHT)<br />

Low voltage release mounting (UVT)<br />

Accessory lead wire terminal platform (LT)<br />

Outer operate handle<br />

Terminal isolation cover<br />

Automatic tripping device<br />

Trip button<br />

10,15,20,30,40,<br />

50,60,75,100<br />

3<br />

600<br />

250<br />

90<br />

155<br />

56<br />

82<br />

132<br />

30<br />

10<br />

14<br />

25<br />

50<br />

10<br />

14<br />

14<br />

25<br />

50<br />

20<br />

14<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-<br />

-<br />

125,150,175,<br />

200,225<br />

3<br />

600<br />

250<br />

105<br />

165<br />

56<br />

84<br />

126<br />

30<br />

10<br />

14<br />

25<br />

50<br />

10<br />

14<br />

25<br />

25<br />

50<br />

20<br />

14<br />

Press terminal<br />

-<br />

-<br />

Have<br />

250,300,<br />

350,400<br />

3<br />

600<br />

250<br />

140<br />

257<br />

95<br />

145<br />

215<br />

44<br />

22<br />

25<br />

35<br />

50<br />

22<br />

25<br />

35<br />

35<br />

50<br />

20<br />

14<br />

Thermal electromagnetism<br />

type


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

A C-09<br />

PME-125 3P<br />

PME-250 3P<br />

PME <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

SPECIFICATION<br />

PME moulded case circuit breaker is highly specified. Positive contact indication is standard,<br />

with three positions ON OFF and centre TRIPPED preventing the MCCB contacts<br />

from being held closed in the event of over current.<br />

PME moulded case circuit breaker 3 & 1 pole units have a trip to test button provided a s st andard.<br />

All main contacts are of quality. Silve alloy construction for durability. Co mply ing with IEC60947-2<br />

is covered by type test and marine approval certification.<br />

1. Moulded case circuit breakers 16 to 200A.<br />

2. Available in three ranges: standard,<br />

standard adjustable,<br />

Hi-break adjustable.<br />

3. Complies with IEC60947-2.<br />

4. Current limiting action provides low values of lot-through energy.<br />

PME STANDARD RANGE<br />

MCCB Description Standard range<br />

Current rating(A)<br />

Standard range<br />

16A<br />

20A<br />

32A<br />

40A<br />

50A<br />

63A<br />

80A<br />

100A<br />

125A<br />

160A<br />

200A<br />

Impulse withstand V.<br />

Utilisation category<br />

Adjustment thermal<br />

Adjustment magnetic<br />

Terminal capacity(Max)<br />

1 pole<br />

List number<br />

PME161<br />

PME201<br />

PME321<br />

PME401<br />

PME501<br />

PME630<br />

PME801<br />

PME1001<br />

PME1251<br />

PME1604<br />

-<br />

8KV<br />

A<br />

Fixed<br />

Fixed<br />

120mm2<br />

Breaking capacity IEC60947 2/BS EN60947-2(AC 50/60Hz)<br />

Icu (KA)<br />

-<br />

690V AC<br />

Ics (KA)<br />

-<br />

Icu (KA)<br />

-<br />

480V AC<br />

Ics (KA)<br />

-<br />

400V AC/<br />

Icu (KA)<br />

-<br />

440V AC<br />

Ics (KA)<br />

-<br />

Icu (KA)<br />

-<br />

380V AC<br />

Ics (KA)<br />

-<br />

220V AC/<br />

Icu (KA)<br />

25<br />

240V AC<br />

Ics (KA)<br />

19<br />

250V DC<br />

Icu (KA)<br />

Ics (KA)<br />

-<br />

-<br />

3 poles<br />

List number<br />

PME163<br />

PME203<br />

PME323<br />

PME403<br />

PME503<br />

PME633<br />

PME803<br />

PME1003<br />

PME1253<br />

PME1603<br />

PME2003<br />

8KV<br />

A<br />

Fixed<br />

Fixed<br />

120mm2<br />

12<br />

12<br />

20<br />

20<br />

25<br />

25<br />

30<br />

30<br />

40<br />

40<br />

37<br />

19


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

A C-10<br />

PAA 100 1P<br />

PAA 250 3P<br />

PAA 400 3P<br />

PAA <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

DESCRIPTION<br />

PAA MCCB is Available in two frame sizes from 25 to 800 A. Loadline series of moulded<br />

case circuit breakers provide overload and short-circuit protection for the full range of transforme<br />

r sizes encountered in normal service. The overload and i nstantaneo us trippin g elements,<br />

adjustable over a wide band, make these MCCBs ideal for many distribution applications.<br />

PAA MCCBs are available in single pole, three poles, three pol es with sw itched neu tral and<br />

switch-disconnector versions. Loadline triple poles PAA Frame circuit breaker and switch-disconnector<br />

are physically interchangeable with PAA breakers for Motor Duty requirments. PAA Frame have<br />

front adjustable overload and fixed instantaneous tripping elements.<br />

SPECIFICATION<br />

Insulation voltage(Ui)-660V ac<br />

Operating voltage(Ue)-415 ac<br />

Rated frequency-~50/60Hz<br />

Reference Calibration-40 (50 on request)<br />

TRIPPING ELEMENT<br />

Overload front adjustable 0.7-1.0 times rated current<br />

Instantaneous-non-adjustable<br />

PAA 25-63A=400A PAA 80-125A=800A PAA 160-250A=1600A<br />

Description<br />

PAA-100<br />

single pole MCCB<br />

triple poles MCCB<br />

PAA-250<br />

PAA Frame<br />

PAA-400<br />

PAA-630<br />

PAA-800<br />

In/A Lowest Setting Current amps<br />

25<br />

32<br />

40<br />

50<br />

63<br />

80<br />

100<br />

125<br />

160<br />

200<br />

225<br />

250<br />

315<br />

400<br />

500<br />

630<br />

800<br />

17.5<br />

22.5<br />

28<br />

35<br />

44<br />

56<br />

70<br />

88<br />

112<br />

140<br />

157.5<br />

175<br />

221<br />

280<br />

350<br />

441<br />

560


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

PDPX-125N 3P<br />

PDPX-250N 3P<br />

A C-11<br />

PDPX <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

DESCRIPTION<br />

Type<br />

Pole number<br />

Rated current In(A)<br />

The electrical characteristic satisfies<br />

En60947 - 2<br />

Rated working voltage<br />

Ue(50-60Hz)<br />

Rated working voltage Ue=(V)<br />

Rated insulation voltage Ui~(V)<br />

Rated impulse voltage Uimp(KV)<br />

Usage group<br />

Moulded case switch type<br />

Limited breaking capacity(KA) 230/240V~<br />

400/415V~<br />

440V~<br />

480/500V~<br />

600V~<br />

690V~<br />

250V<br />

Used breaking capacity lcos(%Icu)<br />

Short-circuit closed capacity(400V~)<br />

Short-time withstand current Icw(KA)<br />

Life (open,close for a time) mechanical<br />

Electrical<br />

Insulation capacity<br />

Protection group<br />

Hot-magnetic trip<br />

Electronic trip<br />

Take to connect the ground to break<br />

Down to probe into the function s the<br />

High choice electronic-trip<br />

Residual current<br />

Bottom<br />

installation<br />

protected modules<br />

On the side<br />

installation<br />

Outer accessories<br />

Control from a distance<br />

Fix type<br />

Insert type<br />

Drawer type<br />

Screw hand handle<br />

Power conversion system<br />

Dimension and weight<br />

Dimension (L W H) (mm) 3 pole<br />

4 pole<br />

Weight(kg)<br />

3 pole<br />

4 pole<br />

PDPX 125 PDPX 250<br />

PDPX-E PDPX PDPX PDPX PDPX-E PDPX<br />

E<br />

22<br />

16<br />

10<br />

8<br />

-<br />

-<br />

16<br />

100<br />

32<br />

3-4<br />

16-125<br />

500<br />

250<br />

500<br />

6<br />

A<br />

35<br />

25<br />

18<br />

12<br />

-<br />

-<br />

25<br />

50<br />

52.5<br />

7000<br />

1000<br />

50<br />

36<br />

20<br />

14<br />

-<br />

-<br />

30<br />

50<br />

75.6<br />

75.6 120 74<br />

101 120<br />

1<br />

1.2<br />

74<br />

60<br />

36<br />

30<br />

25<br />

20<br />

16<br />

36<br />

100<br />

75.6<br />

3-4<br />

25-250<br />

690<br />

250<br />

690<br />

8<br />

A<br />

H<br />

100<br />

70<br />

60<br />

40<br />

25<br />

20<br />

40<br />

75<br />

154<br />

7000<br />

1000<br />

L<br />

170<br />

100<br />

70<br />

40<br />

25<br />

20<br />

40<br />

50<br />

220<br />

105 200 105<br />

140 200<br />

2.5<br />

3.7<br />

105


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

PVL-160X 3P<br />

PVL-250X 3P<br />

A C-12<br />

PVL <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

DESCRIPTION<br />

Type<br />

PVL 160X<br />

PVL250<br />

Type<br />

PVL 160X<br />

PVL 250<br />

120.5<br />

63.5<br />

58<br />

31.5<br />

Rated<br />

current<br />

In(A)<br />

20<br />

32<br />

40<br />

50<br />

63<br />

80<br />

100<br />

125<br />

160<br />

200<br />

255<br />

PVL 160 circuit-breaker<br />

106.5<br />

90.5<br />

87<br />

81.5<br />

4<br />

19<br />

Z<br />

4-(250)d<br />

2.5-(160)<br />

X<br />

11<br />

24<br />

Setting current of<br />

inverse-time<br />

delayed overload<br />

release L I (A)<br />

R<br />

16-20<br />

25-32<br />

32-40<br />

40-50<br />

50-63<br />

63-80<br />

80-100<br />

100-125<br />

125-160<br />

160-200<br />

200-250<br />

High switching capacity H 70 kA<br />

at 380/415V AC<br />

PVL1702-2DD36-...<br />

PVL1703-2DD36-...<br />

PVL1704-2DD36-...<br />

PVL1705-2DD36-...<br />

PVL1706-2DD33-...<br />

PVL1708-2DD36-...<br />

PVL1710-2DD36-...<br />

PVL1712-2DD36-...<br />

PVL1716-2DD36-...<br />

PVL3720-2DD36-...<br />

PVL3725-2DD36-...<br />

88.5<br />

15.5<br />

X<br />

35 35<br />

Y<br />

35<br />

52.5<br />

104.5<br />

139.5<br />

16 32<br />

17.5<br />

6 5.2<br />

75.5<br />

7<br />

13<br />

140<br />

174.5<br />

12 24.5<br />

Operating current of<br />

instantaneous shortcircuit<br />

release I I i<br />

(A)<br />

300<br />

300<br />

600<br />

600<br />

600<br />

1000<br />

1000<br />

1000<br />

1600<br />

1000-2000<br />

200-2500<br />

PVL 250 circuit-breaker<br />

5.5<br />

88.5<br />

11<br />

Y Y<br />

NSK-8840<br />

X<br />

5.5<br />

Standard switching<br />

capacity N 40/45/50kA<br />

at 380/415V AC<br />

PVL1702-1DD33-...<br />

PVL1703-1DD33-...<br />

PVL1704-1DD33-...<br />

PVL1705-1DD33-...<br />

PVL1706-1DD33-...<br />

PVL1708-1DD33-...<br />

PVL1710-1DD36-...<br />

PVL1712-1DD36-...<br />

PVL1716-1DD36-...<br />

PVL3720-1DD36-...<br />

PVL3725-1DD36-...<br />

Very high switching capacity L<br />

100kA at 380/415V AC<br />

35 35<br />

Y<br />

35<br />

16 32<br />

PVL3720-3DC36-...<br />

PVL3725-3DC36-...<br />

PVL 160 and PVL 250<br />

circuit-breakers mounting detail<br />

17.5<br />

6 8.4<br />

13<br />

75.5<br />

149<br />

174.5<br />

185.5<br />

11.5<br />

(8)<br />

18<br />

24.5<br />

70(4P)<br />

52.5<br />

104.5<br />

139.5<br />

NSK-8841<br />

8<br />

X<br />

Y<br />

17.5<br />

35<br />

(3P)<br />

19.5 65<br />

131.5<br />

2 5.2(3P)<br />

4 5.2(4P)


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

100<br />

105<br />

A C-13<br />

PHFD-125N 3P<br />

PHFD-250N 3P<br />

86<br />

152<br />

PHFD <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

DESCRIPTION<br />

PHFD moulded case circuit breakers are the choice of designer for coordinate protection of all<br />

types of low voltage power distribution systems.<br />

Description<br />

Single pole MCCB<br />

Triple poles MCCB<br />

In/A<br />

15<br />

20<br />

25<br />

30<br />

35<br />

40<br />

50<br />

70<br />

90<br />

100<br />

125<br />

150<br />

15<br />

20<br />

25<br />

30<br />

35<br />

40<br />

50<br />

70<br />

90<br />

100<br />

125<br />

150<br />

175<br />

200<br />

225<br />

250<br />

Rated isolating<br />

voltage(V)<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

600<br />

Rated capacity<br />

(KA)<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65<br />

65


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

PHB-126<br />

PHB-226<br />

A C-14<br />

PHB-126 3P<br />

PHB-226 3P<br />

PHB <strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

SPECIFICATION<br />

Manufacture stardand:IEC60947-2<br />

Fixing type thermal trip<br />

Fixing type magnetic trip<br />

MAX. RATED SHORT-<strong>CIRCUIT</strong> BREAKING CAPACITY<br />

Hull<br />

PHB126H<br />

PHB226H<br />

PHB226N<br />

PHB226E<br />

220/240VAC<br />

65kA<br />

35kA<br />

40kA<br />

100kA<br />

Description Rated current(A)<br />

PHB126H-25kA<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

PHB226H-25kA<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

16<br />

20<br />

25<br />

32<br />

40<br />

50<br />

63<br />

80<br />

100<br />

63<br />

80<br />

100<br />

125<br />

160<br />

200<br />

225<br />

380/415VAC 660/690VAC<br />

25kA<br />

-<br />

25kA<br />

-<br />

40kA<br />

12kA<br />

70kA<br />

14kA<br />

Description<br />

PHB226N-40kA<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

PHB226E-70kA<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

MCCB<br />

ACCESSORY AND AUXILIARY EQUIPMENT<br />

Revolve the hand handle the organization<br />

Locks<br />

-AA auxiliary switch,2NO+2NC<br />

-UV Owe-voltage trip,415V~<br />

-SR Cent trip,240V~<br />

-UV2 Owe-voltage trip,240V~<br />

80<br />

72<br />

126<br />

80<br />

250VDC*<br />

10kA<br />

-<br />

10kA<br />

20kA<br />

Rated current(A)<br />

63<br />

80<br />

100<br />

125<br />

160<br />

200<br />

225<br />

63<br />

80<br />

100<br />

125<br />

160<br />

200<br />

225<br />

104.7<br />

85.8<br />

81<br />

226<br />

101.7


<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

PTCD-100<br />

PTCD-100 3P<br />

PEB-100 3P<br />

PQD-250 3P<br />

A C-15<br />

<strong>MOULDED</strong> <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

DESCRIPTION<br />

PTCD\PEB\PQD Series moulded case c ircuit breaker is one of our new type products<br />

developed and manufactured by adopting international adv anced technology. It is supplied with<br />

rated insulating voltage 660V and used for circuit of A.C.50Hz, rated operating voltage AC 380V.<br />

(Or below), rated operati ng current up to 22 5A for infre que nt cha ngi ng ove r and starting of the<br />

motors. Equipped with the protection devices for over-current, shor t-circ uit a nd under-voltage,<br />

the products are capable of preventing damage of circuits and supply units.<br />

DIMENSIONS OF OUTLINE AND INSTALLATION (PQD)<br />

3<br />

8<br />

1<br />

4<br />

1 23<br />

64<br />

SPECIFICATION<br />

Model Pole Rated Current (A)<br />

PTCD<br />

PEB<br />

PQD<br />

11<br />

16<br />

1<br />

3<br />

8<br />

3 30,40,50,60,70,100<br />

3<br />

3<br />

2 4 3<br />

3<br />

1<br />

8<br />

2 23<br />

32<br />

11<br />

32<br />

3 21<br />

32 2 7<br />

14<br />

7<br />

4<br />

8<br />

19<br />

32<br />

3<br />

5 8<br />

6<br />

9<br />

16<br />

3<br />

4<br />

125,150,175,200,225<br />

1<br />

4<br />

1 8<br />

2 1<br />

14<br />

1<br />

14<br />

11<br />

16<br />

1 3 8<br />

25<br />

32<br />

5<br />

32<br />

9<br />

16<br />

23<br />

Rated Insulation<br />

voltage<br />

30,40,50,60,70,100 600V<br />

1<br />

11<br />

16 1 3 8<br />

9<br />

3<br />

32<br />

1<br />

2<br />

2<br />

1<br />

16<br />

23<br />

32 7<br />

15<br />

16<br />

2 5<br />

8<br />

2 16<br />

14<br />

7<br />

3<br />

14<br />

1<br />

32<br />

32<br />

3<br />

1<br />

4<br />

1<br />

32<br />

1<br />

4 1<br />

5<br />

32<br />

Rated operating<br />

voltage<br />

240V<br />

380V<br />

660V<br />

1 9<br />

32


AIR <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

A C-16<br />

RDW1-2000<br />

RDW1-3200<br />

RDW1 AIR <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

SCOPE OF APPLICATION<br />

Type<br />

RDW1-2000<br />

RDW1-3200<br />

4000<br />

RDW1-6300<br />

4000/5000<br />

RDW1-6300<br />

RDW1-2000 cable dimension<br />

for with drawable type<br />

RDW1-3200 In=4000A<br />

Pole<br />

3P<br />

4P<br />

3P<br />

3P<br />

4P<br />

3P<br />

4P<br />

3P<br />

L1<br />

375<br />

470<br />

435<br />

550<br />

550<br />

813<br />

928<br />

928<br />

L2<br />

335<br />

430<br />

395<br />

510<br />

510<br />

773<br />

888<br />

888<br />

RDW1-6300, In=6300A<br />

cable dimension for with drawable type<br />

L3<br />

292<br />

292<br />

352<br />

352<br />

352<br />

352<br />

352<br />

352<br />

L4<br />

356<br />

360<br />

325<br />

440<br />

440<br />

703<br />

818<br />

818<br />

L5<br />

247<br />

247<br />

307<br />

307<br />

307<br />

307<br />

307<br />

307<br />

W1<br />

421<br />

494<br />

W2<br />

467<br />

540<br />

RDW1-3200 cable dimension<br />

for with drawable type<br />

RDW1-6300, In=4000A, 5000A<br />

cable dimension for with drawable type<br />

b<br />

139<br />

212<br />

In A<br />

400~630<br />

800~1600<br />

2000~2500<br />

3200~4000<br />

4000<br />

5000~6300<br />

RDW1-3200 could increase to 4000A,its installation dimension is same with RDW1-3200,4P<br />

a<br />

10<br />

15<br />

20<br />

30<br />

20<br />

30


AIR <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

50kA/400V<br />

40kA/690V<br />

50kA/400V<br />

40kA/690V<br />

RDW1 AIR <strong>CASE</strong> <strong>CIRCUIT</strong> <strong>BREAKER</strong><br />

It can be used as controlling and protecting Electric Power Distribution line & Net. It is normally installed in Low-Voltage Sw itc hge ar as main<br />

Switch for total protection. The technical performance of our goods have reached advanced level of same item in the world.<br />

MAIN TECHNICAL PARAMETER<br />

Frame classing rated current<br />

Rated insulation voltage<br />

Rated voltage<br />

Rated current<br />

Rated ultimate short-circuit breaking capacity(lcu)<br />

Rated service short-circuit breaking capacity(lcs)<br />

Rated withshand current for short-time(lcw)<br />

Number of poles<br />

Arcing distance<br />

Shakable handle &<br />

its depositary<br />

A C-17<br />

2000A 3200A 4000A 6300A<br />

690V<br />

400V<br />

630A,800A,1000A,1250A,1600A,2000A,2500A,3200A,4000A<br />

80kA/400V<br />

50kA/690V<br />

100kA/400V<br />

80kA/690V<br />

80kA/400V<br />

60kA/690V<br />

80kA/400V<br />

65kA/690V<br />

Fault deviate indication/reposit pbutton<br />

Shut button<br />

Manua/Power store handle<br />

Dispart button<br />

Power store & release<br />

indication<br />

Shut & Dispart indication<br />

Panel<br />

In-Out device<br />

Position indication<br />

3P, 4P<br />

AC Rated Current:630A-3200A<br />

Breaking Capacity:80kA-100KA(virtual value)<br />

Rated working voltage: AC960V<br />

Type:Draw-Out type and Fixed Mounted type<br />

Standards: IEC60947-2, GB14048.2<br />

0<br />

100kA/400V<br />

80kA/690V<br />

80kA/400V<br />

65kA/690V<br />

80kA/400V<br />

65kA/690V<br />

120kA/400V<br />

80kA/690V<br />

100kA/400V<br />

70kA/690V<br />

100kA/400V<br />

70kA/690V<br />

Two times loop terminal connector(moving)<br />

Two times loop terminal connector(moving)<br />

Under-Uoltage reloase<br />

Draw-out seating<br />

Shunt release<br />

Awciliary contact<br />

Close electromagnet<br />

Intelligent controller<br />

Electric operation framework<br />

Operation framework

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!