AS-INTERFACE<br />

Safety<br />

Interlock<br />

Switches<br />

Mechanical<br />

Highlights • Steel actuator head<br />

• Key and coil monitoring<br />

• High-visibilty LEDs<br />

Coded<br />

Magnetic<br />

• Direct connection to<br />

AS-Interface<br />

• 1 m pigtail integrated<br />

• IP67 for harsh<br />

environments<br />

• Small mounting<br />

footprint<br />

RFID<br />

• High-end RFID solution<br />

replaces magnetic<br />

interlocks<br />

• Up to 4 doors monitored<br />

from one control unit<br />

• Long read range for<br />

worry free alignment<br />

• High-visibility<br />

diagnostic LEDs<br />

44<br />

Subject to modifications without notice<br />

<strong>Pepperl+Fuchs</strong> Group<br />

USA: +1 330 486 0001<br />

Germany: +49 621 776-4411<br />

Copyright <strong>Pepperl+Fuchs</strong><br />

Singapore: +65 6779 9091<br />

www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@de.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com<br />

Enabling<br />

Switch<br />

• Lightweight enabling<br />

switch<br />

• Rugged rubberized<br />

housing<br />

• Ergonomic design<br />

Input Type Safety, mechanical Safety, magnetic Safety, RFID Safety, mechanical<br />

Input Activations 1,000,000 100,000,000 Unlimited 100,000<br />

Input Powered By AS-Interface AS-Interface AS-Interface AS-Interface<br />

Output Type Solenoid/LEDs<br />

Output Powered By AS-Interface/aux.<br />

CAT 4/SIL 3 Approved n n n n<br />

Safety<br />

Modules<br />

Highlights • Dry-contact inputs for connection of<br />

standard e-stops and gate switches<br />

• Electronic inputs for connection of<br />

light curtains or any device with<br />

electronic OSSDs<br />

Want more information?<br />

Simply go to: www.sensing.net/as-interface<br />

Subject to modifications without notice Copyright <strong>Pepperl+Fuchs</strong><br />

<strong>Pepperl+Fuchs</strong> Group<br />

www.pepperl-fuchs.com<br />

USA: +1 330 486 0001<br />

fa-info@us.pepperl-fuchs.com<br />

Safe Inputs E-Stops Safe Outputs<br />

Germany: +49 621 776-4411<br />

fa-info@de.pepperl-fuchs.com<br />

• AS-i safety e-stop connects directly<br />

to AS-i cable<br />

• Field mount or panel mount e-stop<br />

housings<br />

• Available with or without<br />

illumination<br />

Singapore: +65 6779 9091<br />

fa-info@sg.pepperl-fuchs.com<br />

• One set of redundant relay outputs<br />

• EDM and status inputs<br />

• One address for safety output<br />

channel<br />

• One A/B address for diagnostics<br />

Safe Inputs 1 or 2 1 E-Stop -<br />

Safe Relay Outputs - 1<br />

Standard Inputs/Outputs 2 out 1 out (LED) 1 in/1 out (LED)<br />

CAT 4/SIL 3 Approved n n n<br />

Safety<br />

Monitors<br />

Highlights • Scans up to 31 safe input modules<br />

• 1 channel for safe AS-i outputs<br />

2-Channel Basic 16-Channel Enhanced<br />

• Scans up to 62 safe input modules on two<br />

networks<br />

• 16 channels for safe AS-i outputs<br />

Safe Outputs (onboard) 1 or 2 relay 2 (relay) or 4 (2 relay and 2 electronic)<br />

Safe AS-i Output Channels 1 16<br />

Safe Network Coupling n n<br />

Scan 2 Networks n<br />

Memory Card n<br />

Graphical Display n<br />

CAT 4/SIL 3 Approved n n<br />

Courtesy of <strong>Steven</strong> <strong>Engineering</strong>, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com<br />