BUILDING RESEARCH INSTITUTE<br />

<strong>FIRE</strong> TESTING LABORA<strong>TO</strong>RY<br />

THE GROUP OF TESTING LABORA<strong>TO</strong>RIES<br />

Accredited by the Polish Centre for Accreditation<br />

Certificate of accreditation no. AB 023<br />

<strong>FIRE</strong> TESTING LABORA<strong>TO</strong>RY (LP)<br />

<strong>REACTION</strong> <strong>TO</strong> <strong>FIRE</strong><br />

<strong>CLASSIFICATION</strong> <strong>REPORT</strong><br />

<strong>in</strong> <strong>accordance</strong> <strong>with</strong> EN 13501-1:2007<br />

Agreement no.: NP-512/C/09/MŻ<br />

Order<strong>in</strong>g Party: KRONOPOL Sp. z o.o.<br />

ul. Serbska 56<br />

68-200 Zary<br />

Prepared by: Fire Test<strong>in</strong>g Laboratory<br />

Build<strong>in</strong>g Research Institute<br />

ul. Filtrowa 1<br />

00-611 Warszawa<br />

Name of product: Lam<strong>in</strong>ated chipboards<br />

Classification report no.: NP-512/C/09/MŻ<br />

Issue no.: 1 Copy no.: 1<br />

Date of issue: 2009/04/01<br />

This classification report has been made on five pages and may be used or copied<br />

only <strong>in</strong> its entirety.<br />

1. Introduction<br />

The purpose of this classification report is to def<strong>in</strong>e the classification for lam<strong>in</strong>ated<br />

chipboards <strong>in</strong> <strong>accordance</strong> <strong>with</strong> the procedures described <strong>in</strong> EN 13501-1:2007.<br />

2. Detailed <strong>in</strong>formation on product under classification.<br />

2.1. General provisions<br />

The product has been def<strong>in</strong>ed as lam<strong>in</strong>ated chipboards.<br />

<strong>FIRE</strong> TESTING LABORA<strong>TO</strong>RY<br />

UL. KSAWEROW 21, 02-656 WARSZAWA<br />

Phone: +48 22 8533427 +48 22 8482307<br />

Fax: +48 22 8472311, email: fire@itb.pl<br />

Member of<br />

BUILDING RESEARCH INSTITUTE<br />

www.itb.pl<br />

The Branch of the Laboratory <strong>in</strong> Katowice<br />

Al. Korfantego 191, 40-153 Katowice<br />

Phone: +48 32 7302352, fax: +48 32<br />

7302949 email: fire@itb.katowice.pl


2.2. Product description<br />

Classification report no.: NP-512/C/09/MŻ 2/5<br />

The product description is provided below.<br />

Product description:<br />

Lam<strong>in</strong>ated chipboards.<br />

- thickness of 10 ÷ 38 mm.<br />

The boards are produced <strong>in</strong> the facility located <strong>in</strong> Zary at 56 Serbska Street<br />

3. Test reports and test results that are the basis for the classification<br />

3.1. Test reports<br />

Name of the<br />

laboratory<br />

Fire Test<strong>in</strong>g Laboratory<br />

ITB<br />

Name of the<br />

Order<strong>in</strong>g Party<br />

KRONOPOL Sp. z o.o.<br />

Test report no. Test method<br />

LP-512.1/23-21/09 PN-EN ISO 11925-2<br />

LP-512.2/23-22/09 PN-EN ISO 11925-2<br />

LP-512.1/34-35/09 PN-EN 13823<br />

LP-512.2/34-36/09 PN-EN 13823


3.2. Test results<br />

Classification report no.: NP-512/C/09/MŻ 3/5<br />

Test method Parameter Number<br />

results<br />

of tests Cont<strong>in</strong>uous Compliance<br />

parameter –<br />

mean (m)<br />

parameters<br />

LP-512.1/23-21/09 Flames spread<strong>in</strong>g<br />

(-) T<br />

Fs ≤ 150 mm<br />

6<br />

30 sec. exposure<br />

PN-EN ISO 11925-2<br />

Drops/particles on flames<br />

(-) N<br />

LP-512.2/23-22/09 Flames spread<strong>in</strong>g<br />

(-) T<br />

Fs ≤ 150 mm<br />

6<br />

30 sec. exposure<br />

PN-EN ISO 11925-2<br />

Drops/particles on flames<br />

(-) N<br />

LP-512.1/34-35/09 FIGRA 0,2 MJ 301,9 (-)<br />

FIGRA 0,4 MJ 301,9 (-)<br />

LFS < edge (-) T<br />

THR 600s [MJ] 19,5 (-)<br />

PN-EN 13823<br />

SMOGRA [m2/s2]<br />

TSR 600s [m2]<br />

8,8<br />

70,7<br />

(-)<br />

(-)<br />

Drops/particles on flames<br />

(-) N<br />

LP-512.2/34-36/09 FIGRA 0,2 MJ 300,5 (-)<br />

FIGRA 0,4 MJ 300,5 (-)<br />

LFS < edge (-) T<br />

THR 600s [MJ] 22,6 (-)<br />

PN-EN 13823 SMOGRA [m2/s2] 12,6 (-)<br />

TSR 600s [m2] 72,7 (-)<br />

Drops/particles on flames<br />

(-) N<br />

(-): not applicable<br />

T: YES<br />

N: NO


Classification report no.: NP-512/C/09/MŻ 4/5<br />

4. Classification and field of application<br />

4.1. Classification provision<br />

The classification has been provided <strong>in</strong> <strong>accordance</strong> <strong>with</strong> EN 13501-1:2007<br />

4.2. Classification<br />

In relation to reaction to fire, the lam<strong>in</strong>ated chipboards have received the follow<strong>in</strong>g<br />

classification:<br />

Because of the smoke liberat<strong>in</strong>g the product has received additional classification:<br />

D<br />

S2<br />

Because of the appearance of drops/particles on flames the product has received<br />

additional classification:<br />

d0<br />

The format of classification <strong>in</strong> relation to reaction to fire for the construction materials<br />

except floors and l<strong>in</strong>e products for thermal isolation of wires is as follows:<br />

Fire properties Smoke liberation Drops on flame<br />

D - s 2 , d 0<br />

i.e.: D-s2,d0<br />

Classification <strong>in</strong> relation to the reaction to fire: D-s2,d0<br />

4.3. Field of application<br />

This classification is b<strong>in</strong>d<strong>in</strong>g for the follow<strong>in</strong>g parameters that describe the product:<br />

- lam<strong>in</strong>ated chipboards described <strong>in</strong> paragraph 2.2 of this classification report,<br />

- lam<strong>in</strong>ated chipboards can be attached to the elements represent<strong>in</strong>g the class of<br />

reaction to fire at least A2-s3,d0


5. Restrictions<br />

Classification report no.: NP-512/C/09/MŻ 5/5<br />

The classification granted shall rema<strong>in</strong> <strong>in</strong> force until:<br />

- the test method is changed,<br />

- product norm or technical approval is changed,<br />

the constructional and material changes do not exceed the limits of the field of<br />

application described <strong>in</strong> paragraph 4.3.<br />

This classification report has been issued <strong>in</strong> 2 copies. Certified copies can be issued<br />

by the Fire Test<strong>in</strong>g Laboratory ITB only upon the request of the Owner of the report.<br />

This classification document does not constitute product approval or certificate.<br />

Signed by Approved by<br />

The Head of Fire Test<strong>in</strong>g Laboratory<br />

Mariusz Zolnik Miroslaw Kosiorek<br />