20.06.2013 Views

Online Instrumentation - WTW.com

Online Instrumentation - WTW.com

Online Instrumentation - WTW.com

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>WTW</strong> Measuring Systems for Nitrogen<br />

● re<strong>com</strong>mended by <strong>WTW</strong> suitable ❍ conditionally applicable *Measurement in aeration basin<br />

Ammonium Ammonium and<br />

Nitrate Nitrate and Nitrite<br />

Nitrate<br />

NEW<br />

System<br />

IQ SenSor net TresCon ® IQ SenSor net IQ SenSor net TresCon ® IQ SenSor net<br />

Sensor/Module AmmoLyt ® Plus 700 IQ Module OA 110 VARiON ® Plus 700 IQ NitraLyt ® Plus 700 IQ Module ON 210/OS 210 NitraVis ® 700 IQ (NI)<br />

For information visit www.<strong>WTW</strong>.<strong>com</strong> for a customer care center near you<br />

Methods<br />

for mounting in TresCon ® system for mounting in TresCon ® system<br />

Measured Variable NH4 NH4 NH4 and NO3 NO3 NOX NO2 and NO3 Inlet (determination<br />

❍ ❍ ●<br />

of load)<br />

Aeration (regula-<br />

● ● ● ● ● ●<br />

tion and control)<br />

Effluent<br />

❍ ● ❍ ❍ ● ●<br />

(monitoring)<br />

Autom. Cleaning <strong>com</strong>pressed air cleaning solution <strong>com</strong>pressed air <strong>com</strong>pressed air cleaning solution Ultrasonic (<strong>com</strong>pressed air)<br />

Cleaning Cycles variable automatic 6/12/24 h variable variable automatic 6/12/24 h prior to each measurement<br />

Measuring in-situ after sample preparation* in-situ in-situ after sample preparation* in-situ<br />

Sample Preparation none PurCon ®/PurCon ® Insitu* none none PurCon ®/PurCon ® Insitu* none<br />

Measuring Interval continuous adjustable continuous continuous adjustable adjustable<br />

Response Time quick medium quick quick medium quick<br />

Measuring Method ISE (ion-selective) gas-sensitive ISE (ion-selective) ISE (ion-selective) photometric UV-VIS and UV spectrometric<br />

Accuracy good high good good high high<br />

Cross Sensitivity yes/potassium,<br />

none yes, automatic<br />

yes/chloride,<br />

low autom. <strong>com</strong>pensated<br />

<strong>com</strong>pensation<br />

<strong>com</strong>pensation<br />

<strong>com</strong>pensation<br />

(spectrum)<br />

Calibration factory calibration automatic 6/12/24 h factory calibration factory calibration automatic 6/12/24 h not necessary<br />

Investment Costs low medium low low medium medium<br />

Additional Costs — sample preparation/pump — — sample preparation/pump —<br />

may be required<br />

may be required<br />

Operational Costs low medium low low low none<br />

Consumables electrodes calibration standard/reagent electrodes electrodes calibration standard none<br />

cleaning solution/E pack<br />

cleaning solution/E pack<br />

Parameter<br />

section<br />

Conductivity pH/ORP Dissolved<br />

Oxygen<br />

Nitrogen Turbidity/<br />

Suspended Solids<br />

Sludge level Phosphate Carbon: COD/TOC/<br />

DOC/BOD/SAC<br />

43