<strong>Pump</strong> <strong>Control</strong> <strong>Panels</strong><br />
Class 87, 88<br />
General<br />
Features<br />
▪ Fully Gasketed NEMA 3R Rainproof<br />
Enclosures<br />
▪ 100,000 Amp Interrupting Capacity<br />
with Class R Fuses<br />
▪ Heavy Duty NEMA Starters<br />
▪ Solid State or Ambient Compensated<br />
Bimetal Overload Relays<br />
▪ Heavy Duty Disconnect Handle<br />
▪ Available in Reduced Voltage Versions<br />
▪ Bold Pilot Legend on Front<br />
▪ Generous Accessory Space<br />
▪ Copper Grounding Lug For Three<br />
#6 Wires<br />
▪ UL Listed for Outdoor Use and<br />
Service Equipment File #E14900<br />
8/56<br />
Application<br />
Heavy duty pump control panels are<br />
designed to withstand the most<br />
demanding environments. Typical<br />
applications include irrigation, agriculture,<br />
petrochemical, wastewater treatment<br />
and wherever motor control is<br />
challenged by harsh elements.<br />
Rugged pump control panels utilized<br />
cold forming “tox” process. They are<br />
more rainproof, sleet and ice<br />
resistant than in the past.<br />
Installation is easy. <strong>Panels</strong> are factory<br />
wired to provide flexible control and<br />
protect against short circuits and<br />
overloads. Ample space is provided<br />
for field modifications and installation<br />
of accessories.<br />
The pump control panels feature a full<br />
sized removable auxiliary panel for the<br />
mounting of accessories. The fusible<br />
version features fuse clips for full sized<br />
RK5 or compact class J fuses and<br />
accessory mounting space for the<br />
most commonly used accessories.<br />
Class 87 pump panels become jockey<br />
pump panels with the addition of a<br />
pressure switch (see field modifications).<br />
The jockey pump’s primary function is to<br />
maintain water pressure at a preset level<br />
and thus compensate for possible<br />
shortage of water in the pumping<br />
system. When the water pressure<br />
drops below the preset level, the<br />
pressure switch energizes the starter<br />
which in turn activates the jockey pump.<br />
The water pressure is then brought back<br />
up to the desired level. This insures the<br />
maintenance of proper water pressure<br />
at all times.<br />
Features<br />
Specified by Fortune 500 companies,<br />
ESP100 or thermal starters offer<br />
prolonged service under severe duty<br />
conditions. NEMA rated, these starters<br />
utilize large silver cadmium oxide<br />
contacts and wide copper heat sinks<br />
to ensure rapid heat dissipation and<br />
maximum electrical life.<br />
ESP100 solid state overload<br />
relays provide phase loss protection<br />
for the motor by tripping within three<br />
seconds upon complete loss of one<br />
phase in a three phase circuit. Each<br />
overload has a 2:1 (4:1 in lower ranges)<br />
FLA adjustment range with an<br />
adjustment dial reading out in FLA.<br />
This feature allows for extreme fine<br />
tuning. Their heaterless construction<br />
minimizes energy costs and costs of<br />
cabinet ventilation or cooling. The class<br />
87 pump panel comes with class 10<br />
trip standard.<br />
The ambient compensated bimetal<br />
overload relays are designed to<br />
parallel thermal characteristics of typical<br />
pump motors. They prevent nuisance<br />
trips that may result from operation of<br />
the control in a higher ambient temperature<br />
than that at the pump. These relays<br />
are trip-free, tamperproof and can be set<br />
to reset automatically or manually.<br />
HOA and Start Pushbutton<br />
Every pump panel comes with an HOA<br />
and a start pushbutton.<br />
Half Size Starters<br />
<strong>Siemens</strong> motor matched starters feature<br />
all the rugged performance characteristics<br />
of our NEMA rated starter sizes, but are<br />
fractionally sized to more closely match<br />
your exact motor rating. As a result,<br />
significant economic savings are made<br />
possible without sacrificing the reliability<br />
you expect from a heavy duty starter.<br />
These additional starter sizes have the<br />
reserve capacity to handle occasional<br />
plugging and jogging without de-rating<br />
the device.<br />
<strong>Siemens</strong> motor matched can save hundreds,<br />
even thousands of dollars per project.<br />
<strong>Siemens</strong> motor matched starters comply<br />
with NEMA, UL and CSA standards.<br />
<strong>Siemens</strong> Energy & Automation, Inc.<br />
Industrial <strong>Control</strong>s Catalog
<strong>Panels</strong> are predrilled for easy repositioning<br />
of the fuse trailer block to accommodate<br />
250 and 600 volt fuses and full sized RK<br />
or compact J fuses. Circuit breakers are<br />
also available.<br />
New Heavy Duty Fusible<br />
Disconnect Switch<br />
The disconnect switch has been<br />
made even better to give you greater<br />
advantages:<br />
▪ Visible blades for the highest<br />
level of safety.<br />
▪ Double Break Switching Action<br />
to reduce arcing, increase lifetime<br />
and eliminate the “electric hinge”.<br />
▪ Oversized lugs are standard.<br />
▪ Line side shield to help guard<br />
personnel from contact with live parts.<br />
Motor Circuit Protector<br />
The motor circuit protector provides fast,<br />
accurate fault clearing that will minimize<br />
damage to the motor and control<br />
apparatus and protect branch circuit<br />
conductors. Continuous current ratings<br />
and adjustable trip ranges meet NEC<br />
requirements for full load and locked<br />
rotor currents. The adjustable<br />
instantaneous trip point can be set<br />
precisely to assure fault protection<br />
and eliminate nuisance tripping.<br />
Removable Door<br />
Enclosure door may be lifted off to make<br />
wiring easier.<br />
Mounting Flanges<br />
Convenient flanges at top and bottom<br />
of the enclosure provide easy mounting.<br />
They fit pole or flat surfaces using<br />
keyhole slots.<br />
Quarter Turn Latches<br />
Quarter turns are utilized to secure the<br />
door.<br />
Wind Catches<br />
A wind catch is provided to prevent the<br />
door from slamming shut (or open) due<br />
to high wind conditions.<br />
<strong>Siemens</strong> Energy & Automation, Inc.<br />
Industrial <strong>Control</strong>s Catalog<br />
Safety Disconnect Handle<br />
Up to three padlocks can be used to lock<br />
the disconnect in the OFF position.<br />
Maintenance work can be performed<br />
without hazard to personnel.<br />
External Reset<br />
The overload relay may be quickly reset<br />
by means of a button on the front of the<br />
enclosure.<br />
Bold Pilot Legend<br />
Provides positive indication of the<br />
selector switch position for use to<br />
stop the pump motor.<br />
Ground Lugs<br />
Insures proper connecting of ground<br />
wires and lightning arresters.<br />
UL Listed<br />
Assures proper construction throughout<br />
control panel.<br />
Reduced Voltage<br />
Available in part winding, wye delta and<br />
auto transformer types, these controls<br />
may be necessary where the power<br />
company limits the amount of current<br />
drawn from its lines, or where starting<br />
torque must be reduced.<br />
Fully gasketed NEMA 3/12 weatherproof<br />
enclosures are supplied with<br />
Class 88 reduced voltage starters.<br />
Part Winding Starters apply starting<br />
current in timed steps to minimize<br />
voltage fluctuations.<br />
Auto Transformer Starters maintain<br />
a closed circuit during transition and<br />
eliminate voltage or current surges.<br />
They draw less current than part winding<br />
starters and are well suited for starting<br />
motors over 20 Hp.<br />
Wye Delta starters and motors are<br />
used in areas where the power supply is<br />
inadequate to supply full starting current<br />
without objectionable voltage drop or for<br />
applications where low starting torque is<br />
required. Centrifugal pumps and similar<br />
apparatus requiring a low starting torque<br />
are typical applications. Both ends of all<br />
three windings of the wye delta motor<br />
are brought out so that they may be<br />
accessible for reconnecting from wye<br />
to delta.<br />
<strong>Pump</strong> <strong>Control</strong> <strong>Panels</strong><br />
Class 87, 88<br />
General<br />
Auxiliary Equipment<br />
Pilot Lights are easily installed on the<br />
enclosure. Oil Tight and Heavy Duty, they<br />
meet NEMA A600 requirements.<br />
Lightning Arresters protect the control<br />
panel from lightning induced surges.<br />
Undervoltage and Phase Sensing<br />
Relays protect the pump against low<br />
voltage, voltage imbalance, loss of phase<br />
and phase reversal.<br />
Anti-Backspin Timers prevent the<br />
motor from starting during motor/shaft<br />
backspin.<br />
The TOX Box<br />
<strong>Siemens</strong> uses the TOX process to<br />
manufacture the enclosures for the<br />
pump panels.<br />
Advantages of the TOX process:<br />
▪ Joints are 50-70% stronger.<br />
▪ Since the TOX process compresses<br />
the metal at the joint, it does not<br />
leave the high stresses in the metal.<br />
▪ Increased corrosion resistance.<br />
The protective layer on the metal is<br />
not damaged in the process, but<br />
instead flows with the material.<br />
8/57
Reduced Voltage <strong>Pump</strong> <strong>Panels</strong><br />
Auto Transformer & Part winding [2 step] with Solid State Overload<br />
Selection<br />
Ordering Information<br />
Technical Data see www.sea.siemens.com/controls.<br />
Field Modification Kits see page 8/79.<br />
Factory Modifications see page 8/93.<br />
Dimensions see page 8/110.<br />
Wiring Diagrams see page 8/137.<br />
Replacement Parts see pages 8/152.<br />
Auto Transformer Type<br />
Part Winding 2 Step<br />
8/60<br />
Discount Code: NEMA <strong>Control</strong><br />
Coil and <strong>Control</strong> Voltage<br />
The coil voltage on the contactors will be<br />
the motor voltage. A CPT will be supplied<br />
to provide the control voltage. The control<br />
voltage will be 120V.<br />
To change the control voltage to customer<br />
supplied (no CPT included), change the<br />
9th character to the following:<br />
for 24V , use "J"<br />
for 120V, use "F"<br />
Fusible Disconnect Circuit Breaker<br />
Motor Max OL amp NEMA Half Fuse Clip List Circuit Breaker List<br />
Voltage Hp range Size Size Size Catalog Number Price $ Amps Catalog Number Price $<br />
230 15 22-45 2 — 60A/250V 88FSHT2FG 6402. 50 88FSHT2MG 6487.<br />
20 30-60 — 2 1/2 100A/250V 88GSJT2FG 8659. 100 88GSJT2MG 8836.<br />
30 45-90 3 — 100A/250V 88HSKT2FG 9241. 100 88HSKT2MG 10123.<br />
40 57-115 — 3 1/2 200A/250V 88ISLT2FG 13128. 125 88ISLT2MG 14499.<br />
50 67-135 4 — 200A/250V 88JSMT2FG 13867. 150 88JSMT2MG 15239.<br />
75 100-210 5 — — — — 250 88KSST2MG 23913.<br />
100 100-270 5 — 400A/250V 88KSUT2FG 24013. 400 88KSUT2MG 25670.<br />
200 200-540 6 — — — — 600 88MSXT2MH 42954.<br />
460 25 22-45 2 — 60A/600V 88FSHT4FH 6826. 50 88FSHT4MH 6937.<br />
30 22-45 — 2 1/2 60A/600V 88GSHT4FH 8983. 50 88GSHT4MH 9071.<br />
50 45-90 3 — 100A/600V 88HSKT4FH 9568. 100 88HSKT4MH 10042.<br />
75 57-115 — 3 1/2 200A/600V 88ISLT4FH 13574. 125 88ISLT4MH 14676.<br />
100 67-135 4 — 200A/600V 88JSMT4FH 15146. 150 88JSMT4MH 15601.<br />
150 100-210 5 — — — — 250 88KSST4MH 24560.<br />
200 100-270 5 — 400A/600V 88KSUT4FH 26463. 400 88KSUT4MH 27750.<br />
400 200-540 6 — 600A/600V 88MSXT4FH 38713. 600 88MSXT4MH 42950.<br />
Fusible Disconnect Circuit Breaker<br />
Motor Max OL amp NEMA Half Fuse Clip List Circuit Breaker List<br />
Voltage Hp range Size Size Size Catalog Number Price $ Amps Catalog Number Price $<br />
230 20 20-40 — 1 3/4 100A/250V 88ESGP2FG 3829. 100 88ESGP2MG 3590.<br />
25 22-45 2 — 100A/250V 88FSHP2FG 4145. 100 88FSHP2MG 4014.<br />
40 30-60 — 2 1/2 200A/250V 88GSJP2FG 5855. 100 88GSJP2MG 5701.<br />
50 45-90 3 — 200A/250V 88HSKP2FG 6348. 150 88HSKP2MG 6194.<br />
60 57-115 — 3 1/2 200A/250V 88ISLP2FG 11248. 250 88ISLP2MG 12111.<br />
75 67-135 4 — 400A/250V 88JSMP2FG 11872. 250 88JSMP2MG 12727.<br />
125 100-210 5 — — — — 400 88KSSP2MG 22426.<br />
150 100-270 5 — 600A/250V 88KSUP2FG 22958. 600 88KSUP2MG 23505.<br />
460 30 13-27 — 1 3/4 100A/600V 88ESFP4FH 3829. 50 88ESFP4MH 3590.<br />
40 22-45 2 — 100A/600V 88FSHP4FH 4145. 100 88FSHP4MH 4014.<br />
60 30-60 — 2 1/2 200A/600V 88GSJP4FH 5855. 100 88GSJP4MH 5701.<br />
75 30-60 3 — 200A/600V 88HSJP4FH 6348. 125 88HSJP4MH 6194.<br />
100 57-115 — 3 1/2 200A/600V 88ISLP4FH 11248. 150 88ISLP4MH 12111.<br />
150 67-135 4 — 400A/600V 88JSMP4FH 11872. 250 88JSMP4MH 12727.<br />
250 100-210 5 — — — — 400 88KSSP4MH 23505.<br />
350 100-270 5 — 600A/600V 88KSUP4FH 22958. 600 88KSUP4MH 42287.<br />
<strong>Siemens</strong> Energy & Automation, Inc.<br />
Industrial <strong>Control</strong>s Catalog
Ordering Information<br />
Technical Data see www.sea.siemens.com/controls.<br />
Field Modification Kits see page 8/79.<br />
Factory Modifications see page 8/93.<br />
Dimensions see page 8/110.<br />
Wiring Diagrams see page 8/137.<br />
Replacement Parts see pages 8/152.<br />
Wye Delta<br />
<strong>Siemens</strong> Energy & Automation, Inc.<br />
Industrial <strong>Control</strong>s Catalog<br />
Discount Code: NEMA <strong>Control</strong><br />
Reduced Voltage <strong>Pump</strong> <strong>Panels</strong><br />
Wye Delta with Solid State Overload<br />
Open Transition Closed Transition<br />
Coil and <strong>Control</strong> Voltage<br />
Selection<br />
The coil voltage on the contactors will be<br />
the motor voltage. A CPT will be supplied<br />
to provide the control voltage. The control<br />
voltage will be 120V.<br />
To change the control voltage to customer<br />
supplied (no CPT included), change the<br />
9th character to the following:<br />
for 24V , use "J"<br />
for 120V, use "F"<br />
Fusible Disconnect Circuit Breaker Fusible Disconnect Circuit Breaker<br />
Motor NEMA Half<br />
Fuse<br />
Clip MCP Catalog List Catalog List Catalog List Catalog List<br />
Voltage Max Hp Size Size Amps Amps Number Price $ Number Price $ Number Price $ Number Price $<br />
10 1 — 60 50 88DSF06FD 4815. 88DSF06MD 5115. 88DSFC6FD 6209. 88DSFC6MD 6510.<br />
15 — 1 3⁄4 100 100 88ESG06FD 5408. 88ESG06MD 5385. 88ESGC6FD 6564. 88ESGC6MD 6818.<br />
20 2 — 100 100 88FSH06FD 6163. 88FSH06MD 5909. 88FSHC6FD 7303. 88FSHC6MD 7350.<br />
30 — 2 1⁄2 200 125 88GSJ06FD 7727. 88GSJ06MD 7820. 88GSJC6FD 9091. 88GSJC6MD 9491.<br />
200V 40 3 — 200 150 88HSK06FD 8320. 88HSK06MD 8721. 88HSKC6FD 10077. 88HSKC6MD 10477.<br />
50 — 3 1⁄2 200 250 88ISL06FD 14622. 88ISL06MD 15616. 88ISLC6FD 16802. 88ISLC6MD 18181.<br />
60 4 — 400 250 88ISL06FD 15161. 88JSM06MD 16540. 88ISLC6FD 18097. 88JSMC6MD 19476.<br />
75 5 — 400 400 88KSS06FD 22808. 88KSS06MD 26667. 88KSSC6FD 30458. 88KSSC6MD 30381.<br />
150 5 — 600 600 88KSU06FD 27573. 88KSU06MD 27080. 88KSUC6FD 31425. 88KSUC6MD 30932.<br />
300 6 — — 800 — — 88MSX06MD 50276. — — 88MSXC6MD 59706.<br />
10 1 — 60 50 88DSF02FG 4815. 88DSF02MG 5115. 88DSFC2FG 6209. 88DSFC2MG 6510.<br />
15 — 1 3⁄4 60 50 88ESG02FG 5323. 88ESG02MG 5385. 88ESGC2FG 6479. 88ESGC2MG 6818.<br />
25 2 — 100 100 88FSH02FG 6163. 88FSH02MG 5909. 88FSHC2FG 7303. 88FSHC2MG 7350.<br />
30 — 2 1⁄2 200 100 88GSJ02FG 7727. 88GSJ02MG 7820. 88GSJC2FG 9091. 88GSJC2MG 9491.<br />
230V 50 3 — 200 150 88HSK02FG 8320. 88HSK02MG 8721. 88HSKC2FG 10077. 88HSKC2MG 10477.<br />
60 — 3 1⁄2 200 250 88ISL02FG 14622. 88ISL02MG 15616. 88ISLC2FG 16802. 88ISLC2MG 18181.<br />
75 4 — 400 250 88JSM02FG 15161. 88JSM02MG 16540. 88JSMC2FG 18097. 88JSMC2MG 19476.<br />
100 5 — 400 400 88KSS02FG 22808. 88KSS02MG 26667 88KSSC2FG 30458. 88KSSC2MG 30381.<br />
150 5 — 600 600 88KSU02FG 27573. 88KSU02MG 27080. 88KSUC2FG 31425. 88KSUC2MG 30932.<br />
350 6 — — 1200 — — 88MSX02MG 50276. — — 88MSXC2MG 59706.<br />
15 1 — 60 30 88DSE04FH 4815. 88DSE04MH 5115. 88DSEC4FH 6209. 88DSEC4MH 6510.<br />
30 — 1 3⁄4 60 50 88ESF04FH 5339. 88ESF04MH 5385. 88ESFC4FH 6494. 88ESFC4MH 6818.<br />
40 2 — 100 100 88FSH04FH 5855. 88FSH04MH 5909. 88FSHC4FH 7465. 88FSHC4MH 7519.<br />
60 — 2 1⁄2 200 100 88GSJ04FH 7419. 88GSJ04MH 7820. 88GSJC4FH 9260. 88GSJC4MH 9661.<br />
460V 75 3 — 200 125 88GSJ04FH 8320. 88HSK04MH 8721. 88GSJC4FH 10901. 88HSKC4MH 11302.<br />
100 — 3 1⁄2 200 150 88ISL04FH 12727. 88ISL04MH 15616. 88ISLC4FH 17373. 88ISLC4MH 19044.<br />
150 4 — 400 250 88JSM04FH 15161. 88JSM04MH 16540. 88JSMC4FH 18775. 88JSMC4MH 20154.<br />
200 5 — 400 400 88KSS04FH 22808. 88KSS04MH 26667. 88KSSC4FH 31151. 88KSSC4MH 31074.<br />
300 5 — 600 600 88KSU04FH 27573. 88KSU04MH 27080. 88KSUC4FH 33096. 88KSUC4MH 32603.<br />
700 6 — — 1200 — — 88MSX04MH 50276. — — 88MSXC4MH 59706.<br />
15 1 — 60 30 88DSE05FE 4815. 88DSE05ME 5115. 88DSEC5FE 6209. 88DSEC5ME 6510.<br />
30 — 1 3⁄4 60 50 88ESF05FE 5339. 88ESF05ME 5385. 88ESFC5FE 6494. 88ESFC5ME 6818.<br />
40 2 — 60 50 88FSF05FE 5855. 88FSF05ME 5909 88FSFC5FE 7465. 88FSFC5ME 7519.<br />
60 — 2 1⁄2 100 100 88GSH05FE 7419. 88GSH05ME 7820. 88GSHC5FE 9260. 88GSHC5ME 9661.<br />
575V 75 3 — 200 125 88HSJ05FE 8320. 88HSJ05ME 8721. 88HSJC5FE 10901. 88HSJC5ME 11302.<br />
100 — 3 1⁄2 200 150 88ISK05FE 12727. 88ISK05ME 15616. 88ISKC5FE 17373. 88ISKC5ME 19044.<br />
150 4 — 400 250 88ISK05FE 15161. 88JSM05ME 16540 88ISKC5FE 18775. 88JSMC5ME 20154.<br />
200 5 — 400 400 88KSS05FE 22808. 88KSS05ME 26667. 88KSSC5FE 31151. 88KSSC5ME 31074.<br />
300 5 — 600 400 88KSU05FE 27573. 88KSU05ME 27080. 88KSUC5FE 33096. 88KSUC5ME 32603.<br />
700 6 — — 1200 — — 88MSX05ME 50276. — — 88MSXC5ME 59706.<br />
8/61
<strong>Pump</strong> <strong>Control</strong> <strong>Panels</strong><br />
Standard <strong>Pump</strong> Panel with Solid State Overload<br />
Selection<br />
Coil Table<br />
60Hz Voltage Letter<br />
24 Separate <strong>Control</strong><br />
120 Separate <strong>Control</strong><br />
110–120/220–240<br />
J<br />
F<br />
A 200–208<br />
220–240<br />
220–240/440–480<br />
D<br />
G<br />
C 277<br />
440–480<br />
550–600<br />
L<br />
H<br />
E<br />
Fusible Disconnect<br />
200V 230V 460V 575V NEMA Size Half Size Overload Amp Range Fuse Clip Amps Catalog Number List Price $<br />
— — 1 1 1 — 0.75-3 Ordering Information<br />
Technical Data see www.sea.siemens.com/controls.<br />
<br />
<br />
<br />
Field Modification Kits see page 8/79.<br />
Factory Modifications see page 8/93.<br />
Dimensions see page 8/110.<br />
<br />
<br />
Wiring Diagrams see page 8/137.<br />
Replacement Parts see pages 8/152.<br />
Sizes 1-4 will be supplied standard with a 240/480 volt coil.<br />
To change the coil voltage, change the 8th character in the catalog<br />
number to the letter shown in the coil table.<br />
Sizes 5&6 will be supplied standard with a 480 volt coil. To change<br />
the coil voltage, change the 8th character in the catalog number to<br />
the letter shown in the coil table.<br />
30 87DSB6FC 1017.<br />
— — 5 5 1 — 2.5-10 30 87DSD6FC 1017.<br />
— — 7 1/2 10 1 — 9-18 30 87DSE6FC 1017.<br />
— — 7 1/2 10 1 — 9-18 60 87DSE60C 1032.<br />
— — 15 15 — 1 3/4 13-27 30 87ESF6FC 1194.<br />
— — 15 15 — 1 3/4 13-27 60 87ESF60C 1210.<br />
— — 15 20 2 — 13-27 60 87FSF6FC 1371.<br />
— — 25 25 2 — 22-45 60 87FSH6FC 1371.<br />
— — 25 25 2 — 22-45 100 87FSH60C 1456.<br />
— — 30 30 — 2 1/2 22-45 60 87GSH6FC 1957.<br />
— — 30 30 — 2 1/2 22-45 100 87GSH60C 2042.<br />
— — 50 50 3 — 45-90 100 87HSK6FC 2211.<br />
— — 50 50 3 — 45-90 200 87HSK60C 2373.<br />
— — 75 75 — 3 1/2 57-115 200 87ISL6FC 3760.<br />
— — 100 100 4 — 67-135 200 87JSM6FC 4068.<br />
— — 200 200 5 — 100-270 400 87KSU6FH 8844.<br />
— — 250 — 6 — 200-540 600 87MSW6FH 22330.<br />
2 2 — — 1 — 2.5-10 30 87DSD6LC 1002.<br />
3 3 — — 1 — 9-18 30 87DSE6LC 1002.<br />
7 1/2 7 1/2 — — 1 — 13-27 30 87DSF6LC 1002.<br />
7 1/2 7 1/2 — — 1 — 13-27 60 87DSF6PC 1017.<br />
10 10 — — — 1 3/4 20-40 60 87ESG6LC 1194.<br />
10 15 — — 2 — 22-45 60 87FSH6LC 1348.<br />
10 15 — — 2 — 22-45 100 87FSH6PC 1441.<br />
15 20 — — — 2 1/2 30-60 60 87GSJ6LC 1903.<br />
15 20 — — — 2 1/2 30-60 100 87GSJ6PC 1995.<br />
25 30 — — 3 — 45-90 100 87HSK6LC 2165.<br />
25 30 — — 3 — 45-90 200 87HSK6PC 2342.<br />
30 40 — — — 3 1/2 57-115 200 87ISL6LC 3729.<br />
40 50 — — 4 — 67-135 200 87JSM6LC 4037.<br />
75 100 — — 5 — 100-270 400 87KSU6LH 8659.<br />
Circuit Breaker<br />
200V 230V 460V 575V NEMA Size Half Size Overload Amp Range Motor Circuit Catalog Number List Price $<br />
Interrupter<br />
ETI Amps<br />
1/2 1/2 1 1 1 — 0.75-3 3 87DSB6MC 1279.<br />
1 1 3 3 1 — 2.5-10 10 87DSC6MC 1279.<br />
2 2 5 5 1 — 2.5-10 10 87DSD6MC 1279.<br />
3 3 7 1/2 10 1 — 9-18 25 87DSE6MC 1279.<br />
7 1/2 7 1/2 10 — 1 — 13-27 30 87DSF6MC 1279.<br />
— — 15 15 — 1 3/4 13-27 30 87ESF6MC 1433.<br />
10 10 — — — 1 3/4 20-40 50 87ESG6MC 1433.<br />
— — 15 20 2 — 13-27 30 87FSF6MC 1587.<br />
10 15 25 25 2 — 22-45 50 87FSH6MC 1587.<br />
— — 30 30 — 2 1/2 22-45 50 87GSH6MC 2072.<br />
15 20 — — — 2 1/2 30-60 100 87GSJ6MC 2072.<br />
25 30 50 50 3 — 45-90 100 87HSK6MC 2242.<br />
30 40 75 75 — 3 1/2 57-115 125 87ISL6MC 4438.<br />
40 50 100 100 4 — 67-135 150 87JSM6MC 4746.<br />
50 75 150 200 5 — 100-270 250 87KST6MH 10793.<br />
75 100 200 200 5 — 100-270 400 87KSU6MH 10793.<br />
100 125 250 300 6 — 200-540 400 87MSW6MH 23401.<br />
150 200 400 400 6 — 200-540 600 87MSX6MH 26902.<br />
Not available on Size 5 and larger.<br />
8/58<br />
For an overload amp range of 0.25-1A, change the 5th<br />
character from a 'B' to an 'A'.<br />
Discount Code: NEMA <strong>Control</strong><br />
<strong>Siemens</strong> Energy & Automation, Inc.<br />
Industrial <strong>Control</strong>s Catalog
Ordering Information<br />
Order 3 heater elements by code number at 11.60 each see page 8/145.<br />
Technical Data see www.sea.siemens.com/controls<br />
Field Modification Kits see page 8/79.<br />
Factory Modifications see page 8/93.<br />
Dimensions see page 8/110.<br />
Wiring Diagrams see page 8/137.<br />
Replacement Parts see pages 8/152.<br />
Sizes 1-4 will be supplied standard with a 230/480 volt coil. To change the coil<br />
voltage, change the 8th character in the catalog number to the letter shown in<br />
the coil table.<br />
Sizes 5&6 will be supplied standard with a 480 volt coil. To change the coil<br />
voltage, change the 8th character in the catalog number to the letter shown<br />
in the coil table.<br />
Fusible Disconnect<br />
<strong>Siemens</strong> Energy & Automation, Inc.<br />
Industrial <strong>Control</strong>s Catalog<br />
<strong>Pump</strong> <strong>Control</strong> <strong>Panels</strong><br />
<strong>Pump</strong> Panel with Ambient Compensated Bimetal Overload<br />
Discount Code: NEMA <strong>Control</strong><br />
Coil Table<br />
Selection<br />
60Hz Voltage Letter<br />
24 Separate <strong>Control</strong> J<br />
120 Separate <strong>Control</strong> F<br />
110–120/220–240 A <br />
200–208 D<br />
220–240 G<br />
220–240/440–480 C <br />
277 L<br />
440–480 H<br />
550–600 E<br />
200V 230V 460V 575V NEMA Size Half Size Fuse Clip Amps Catalog Number List Price $<br />
— — 10 10 1 — 30 87DAE6FC 982.<br />
— — 10 10 1 — 60 87DAE60C 998.<br />
— — 15 15 — 1 3/4 30 87EAF6FC 1159.<br />
— — 15 15 — 1 3/4 60 87EAF60C 1175.<br />
— — 25 25 2 — 60 87FAJ6FC 1337.<br />
— — 25 25 2 — 100 87FAJ60C 1421.<br />
— — 30 30 — 2 1/2 60 87GAK6FC 1922.<br />
— — 30 30 — 2 1/2 100 87GAK60C 2007.<br />
— — 50 50 3 — 100 87HAN6FC 2176.<br />
— — 50 50 3 — 200 87HAN60C 2338.<br />
— — 75 75 — 3 1/2 200 87IAP6FC 3725.<br />
— — 100 100 4 — 200 87JAR6FC 4033.<br />
7 1/2 7 1/2 — — 1 — 30 87DAE6LC 967.<br />
7 1/2 7 1/2 — — 1 — 60 87DAE6PC 982.<br />
10 10 — — — 1 3/4 60 87EAG6LC 1159.<br />
10 15 — — 2 — 60 87FAJ6LC 1314.<br />
10 15 — — 2 — 100 87FAJ6PC 1406.<br />
15 20 — — — 2 1/2 100 87GAL6LC 1961.<br />
25 30 — — 3 — 100 87HAN6LC 2130.<br />
25 30 — — 3 — 200 87HAN6PC 2307.<br />
30 40 — — — 3 1/2 200 87IAP6LC 3694.<br />
40 50 — — 4 — 200 87JAR6LC 4002.<br />
Circuit Breaker<br />
200V 230V 460V 575V NEMA Size Half Size Motor Circuit Catalog Number List Price $<br />
Interrupter<br />
ETI<br />
1/2 1/2 1 1 1 — 3 87DAA6MC 1244.<br />
1 1 3 3 1 — 10 87DAB6MC 1244.<br />
3 3 7 1/2 7 1/2 1 — 25 87DAD6MC 1244.<br />
7 1/2 7 1/2 10 10 1 — 30 87DAE6MC 1244.<br />
7 1/2 7 1/2 15 15 — 1 3/4 30 87EAF6MC 1398.<br />
10 10 — — — 1 3/4 50 87EAG6MC 1538.<br />
— — 15 20 2 — 40 87FAH6MC 1552.<br />
10 15 25 25 2 — 50 87FAJ6MC 1552.<br />
— — 30 30 — 2 1/2 50 87GAK6MC 2038.<br />
15 20 — — — 2 1/2 100 87GAL6MC 2038.<br />
25 30 50 50 3 — 100 87HAN6MC 2207.<br />
30 40 75 75 — 3 1/2 125 87IAP6MC 4403.<br />
40 50 100 100 4 — 150 87JAR6MC 4711.<br />
Not available on Size 5 or larger.<br />
8/59
Vacuum Starter <strong>Pump</strong> <strong>Panels</strong><br />
With Solid-State Overload Relay<br />
Selection<br />
Ordering Information<br />
Technical Data see www.sea.siemens.com/controls.<br />
Field Modification Kits see page 8/79.<br />
Factory Modifications see page 8/93.<br />
Dimensions see page 8/110.<br />
Wiring Diagrams see page 8/137.<br />
Replacement Parts see pages 8/152.<br />
Sizes 1-4 will be supplied standard with a 240/480 volt coil. To<br />
change the coil voltage, change the 8th character in the catalog<br />
number to the letter shown in the coil table.<br />
Sizes 5&6 will be supplied standard with a 480 volt coil. To change<br />
the coil voltage, change the 8th character in the catalog number to<br />
the letter shown in the coil table.<br />
Fusible Disconnect<br />
8/62<br />
Discount Code: NEMA <strong>Control</strong><br />
Coil Table<br />
60Hz Voltage ***<br />
024 Separate <strong>Control</strong> 024<br />
120 120<br />
208 208<br />
277 277<br />
480 480<br />
600 600<br />
Max Hp<br />
460 Volts 575 Volts NEMA Size Overload Range Fuse Clip Amps Catalog Number List Price $<br />
100 100 4 55-250A 200A/600V 87JCM4F 7059.<br />
200 200 5 55-250A 400A/600V 87KCU4F* 11363.<br />
Circuit Breaker<br />
Max Hp<br />
460 Volts 575 Volts NEMA Size Overload Range Circuit Breaker Rating Catalog Number List Price $<br />
100 100 4 55-250A 250A 87JCM4M* 7810.<br />
200 200 5 55-250A 250A 87KCT4M* 13416.<br />
250 300 6 200-540A 400A 87MCW4M* 29928.<br />
400 400 6 200-540A 600A 87MCX4M* 29928.<br />
<strong>Siemens</strong> Energy & Automation, Inc.<br />
Industrial <strong>Control</strong>s Catalog