FLOW REGULATOR TYPICAL INSTALLATION IN SQUARE MANHOLE<br />

FIGURE 4 ( MODEL <strong>VHV</strong> )<br />

Model<br />

Number<br />

<strong>Regulator</strong><br />

Diameter<br />

A (mm)<br />

Manhole<br />

Min. width<br />

B (mm)<br />

Minimum<br />

Outlet Pipe<br />

C (mm<br />

Minimum<br />

Clearance<br />

H (mm)<br />

50<strong>VHV</strong>-1 203 600 150 127<br />

75<strong>VHV</strong>-1 280 600 150 152<br />

100<strong>VHV</strong>-1 356 600 150 203<br />

125<strong>VHV</strong>-2 330 600 200 203<br />

150<strong>VHV</strong>-2 406 600 200 229<br />

200<strong>VHV</strong>-2 533 900 254 305<br />

250<strong>VHV</strong>-2 660 900 300 356<br />

300<strong>VHV</strong>-2 787 1200 375 406<br />

350<strong>VHV</strong>-2 914 1200 375 508<br />

Minimum clearance “H” relates to the diameter indicated in the chart.<br />

If the outlet diameter decreases, the “H” clearance will also decrease.