24.07.2013 Views

BRONCHOSCOPE BRONCHOSCOPE – VIDEO

BRONCHOSCOPE BRONCHOSCOPE – VIDEO

BRONCHOSCOPE BRONCHOSCOPE – VIDEO

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>BRONCHOSCOPE</strong> <strong>BRONCHOSCOPE</strong> <strong>–</strong> <strong>VIDEO</strong><br />

I. <strong>VIDEO</strong> <strong>VIDEO</strong> <strong>BRONCHOSCOPE</strong><br />

<strong>BRONCHOSCOPE</strong><br />

1. Should have a minimum angle of view of 120º.<br />

2. Should have a depth of field from 3 to 50mm<br />

3. The insertion tube should have maximum 6±0.2mm diameter<br />

4. Should have an instrument channel of at least 2.2mm inner diameter.<br />

5. Should have a minimum working length of 600±10mm.<br />

6. Should have minimum 180/100 degrees up/down angulations<br />

7. Should be supplied with all standard accessories including different types of biopsy<br />

forceps <strong>–</strong> 2nos. each, leakage tester-1no., cleaning brushes <strong>–</strong> 3 nos and storage box<br />

II II. II <strong>VIDEO</strong> <strong>VIDEO</strong> PROCESSOR PROCESSOR AND AND LIGHT LIGHT SOURCE SOURCE<br />

SOURCE<br />

1. Should be a single chip camera.<br />

2. Should have RGB, S-video, composite video output and all these types of video cables<br />

should be provided.<br />

3. Should have automatic white balance function.<br />

4. Should have fully automatic exposure control.<br />

5. Should have in-built 150W halogen / Xenon 100 W light source<br />

6. Should have a stand-by lamp and should glow in the event of failure of the primary<br />

lamp only in case of halogen light source.<br />

7. Should work with input 200 to 240Vac 50 Hz supply.<br />

III III. III MONITOR<br />

MONITOR<br />

1. Should be a 14 /16 inches LCD TFT medical grade monitor<br />

2. Should have provision for accepting RGB, S-video and composite video signal.<br />

3. Should have minimum 1Kx1K resolution.<br />

4. Should have wide viewing angle.<br />

5. Should work with input 200 to 240Vac 50 Hz supply.<br />

IV IV. IV<br />

OTHERS OTHERS<br />

1. Should be supplied with suitable trolley<br />

2. Trolley should have at least 5 power sockets to connect the processor, monitor etc.<br />

3. Should have safety certificate from a competent authority CE / FDA (US) / STQC CB<br />

certificate / STQC S certificate or valid detailed electrical and functional safety test report<br />

from ERTL. Copy of the certificate / test report shall be produced along with the<br />

technical bid.


Standard Accessories<br />

SL.NO Description QTY<br />

1 BF-IT150 Olympus Actera<br />

Bronchovideoscope with<br />

Standard Accessories<br />

1<br />

2 CV-150 Video Processor for V150 1<br />

3 LMD-1530 Sony Monitor<br />

15”Medical Grade<br />

1<br />

4 Trolley 1<br />

5 MB-155 Leakage Tester 1<br />

6 FB-211D Disposable Biopsy<br />

Forceps<br />

2 Pcs<br />

7 BC-202D-2010-Cytology Brush 2 Pcs<br />

8 NA-601D-1519 single use<br />

Aspiration Needle<br />

2 Pcs<br />

9 BW-15B Channel Cleaning Brush 3 Pcs<br />

10 MH-507 Cleaning Brush for<br />

Biopsy port, Suction Cylinder<br />

3 Pcs