ACDC Surge Protector Type-PI 780 Red Series (http://shop.acdc-dcac.eu/)
ACDC DCAC Company as manufacturer of Multi-Stage Surge Protectors has opened online web store that is available for worldwide buyers ( http://shop.acdc-dcac.eu ). Necessity about this step was requested from many of our customers which have required our sophisticated multi-stage surge protection for their electrical devices. Our online store provides quick and easy order and fast post-delivery to your door.
ACDC DCAC Company as manufacturer of Multi-Stage Surge Protectors has opened online web store that is available for worldwide buyers ( http://shop.acdc-dcac.eu ). Necessity about this step was requested from many of our customers which have required our sophisticated multi-stage surge protection for their electrical devices. Our online store provides quick and easy order and fast post-delivery to your door.
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
MULTI-STAGE SURGE PROTECTION<br />
<strong>ACDC</strong> SURGE PROTECTOR<br />
NINE (9) STAGES SERIES PROTECTOR 1/1 & 3/3<br />
HARD WIRE INSTALLATION- MODULAR SYSTEM<br />
CLASS<br />
LPZ<br />
IP<br />
I+II+III 0 1 2<br />
3<br />
20<br />
82<br />
45<br />
36<br />
SIDE VIEW<br />
Empowered by Innovation<br />
home telecom IT center industry<br />
50<br />
70<br />
72<br />
TOP VIEW<br />
Innovation Approuch to <strong>Surge</strong> Protection<br />
<strong>ACDC</strong> Multi-Stage <strong>Surge</strong> <strong>Protector</strong>s have built-in five ( 5)<br />
patents and use four (4) complementary different prote-<br />
cti on technologies, (Varistor, Gas Tube, Nanocrystalline<br />
Cores and TVS technology) in one unit . That result with<br />
re ducing the surge current up to 99.9% at single point.<br />
T<br />
his characteristic can not offer competitive surge pro-<br />
ducts and present a fundamental improvement in<br />
<strong>Surge</strong> Protection technology. Implementation of <strong>ACDC</strong><br />
<strong>Surge</strong> <strong>Protector</strong>s a re simple and applicable f or professions<br />
such as planners, construction engineers, designers,<br />
electricians and others.<br />
18<br />
Sur SurGe <strong>Type</strong>-<strong>PI</strong> <strong>780</strong> <strong>Red</strong> <strong>Series</strong><br />
Single/Three Phase CLASS I+II+III<br />
Load Rating: 120VAC /230VAC /400VAC & 100A<br />
Single Phase Total <strong>Surge</strong> Cur.: 105 kA (8x20µ s); 15 kA (10x350µ s)<br />
Three Phase Total <strong>Surge</strong> Cur.: 315 kA (8x20µ s); 45 kA (10x350µ s)<br />
Response Time: < 1ns<br />
SurGe Protection<br />
<strong>ACDC</strong> <strong>Surge</strong> <strong>Protector</strong> <strong>Type</strong> - <strong>PI</strong> <strong>780</strong> <strong>Red</strong> <strong>Series</strong> is advance d multi- stage surge protector consists of 9 ( nine ) & 100 A protection stages<br />
that provide s effective and reliable protection against surges and transients<br />
coupled with high grade EMI/RFI filtering. The protector have separate<br />
cascade bi-directional filtering of phase (L) and n<strong>eu</strong>tral (N) wire with option<br />
for ground (GND) filtering.<br />
Application: The scope of applications of <strong>ACDC</strong> <strong>Surge</strong> <strong>Protector</strong>s is quite<br />
wide and refers to the protection of electrical devices against impulse surge<br />
and high-frequency (electromagnetic) disturbance, oscillation, speaks in<br />
network power supply and atmospheric discharge. Those protectors have<br />
high-grade bidirectional filtering and they are tracking AC waveform of<br />
power network supply. <strong>ACDC</strong> <strong>Surge</strong> protectors are filtering the network<br />
pollution and ensures the delivered AC waveform to be sinusoidal as possible.<br />
These protectors have special design to protect and improve functioning of<br />
sophisticate equipment in Telecommunications, Broadcast, Medical<br />
equipment, Computers, Military, Solar Photovoltaic and Residental.<br />
Technical Specifications: The basic module of type <strong>ACDC</strong> <strong>Surge</strong> <strong>Protector</strong> -<br />
<strong>Red</strong> <strong>Series</strong> is 9 ( nine)<br />
stages Single Phase <strong>Protector</strong> with modular<br />
configuration for single or three phase applications for load currents of up to<br />
100A per phase.<br />
Investment: Installation of <strong>ACDC</strong> <strong>Surge</strong> <strong>Protector</strong> type - <strong>PI</strong> is excellent<br />
choice for investment in the quality of your power network supply, extended<br />
equipment life and reduce their down time and errors.<br />
Reliability: If the stages 2,4 and 6 are out of function, the stages 1,3,7 and<br />
8 are still provide a high grade cascade bi-directional filtering along with<br />
ultimate (5-th) protection stage.<br />
www.<strong>acdc</strong>-<strong>dcac</strong>.<strong>eu</strong>
Technical Specification<br />
<strong>Type</strong> - <strong>PI</strong> <strong>780</strong> <strong>Red</strong> <strong>Series</strong> Sur<br />
Technology<br />
Multi-Stage <strong>Surge</strong> Protection<br />
Nine (9) Stages <strong>Series</strong> <strong>Protector</strong><br />
Specification<br />
Cascade bi-directional EMI-RFI filtering of<br />
phase (L), n<strong>eu</strong>tral (N) and ground (GND) wire<br />
Load<br />
Up to 100A per phase; 12kW per phase for<br />
120VAC; 22kW per phase for 230VAC<br />
Basic Options<br />
Indication for bed grounding<br />
Remote alarm<br />
Installation<br />
Hard wire installation<br />
Modular System<br />
Product Standard<br />
IEC61643-1 Class I+II+III; IEC60939-2<br />
Protection Stage<br />
<strong>Type</strong><br />
<strong>Type</strong> - <strong>PI</strong> <strong>780</strong> 1/1-RS<br />
Order Code<br />
Weight (kg)<br />
0,47<br />
Basic Circuit Diagram per Phase - <strong>Red</strong> <strong>Series</strong>:<br />
Single Phase Three Phase Three Phase Three Phase<br />
800.135-1/1<br />
Total <strong>Surge</strong> Cur.<br />
105kA(8/20μs) or 15kA(10/350μs)<br />
Dimension (WxDxHmm)<br />
82x72x70<br />
SurGe Technical Specification per Phase<br />
1. First stage L=0.7mH; Imax=up to 100A<br />
2. Second stage<br />
3. Third stage<br />
4. Fourth stage<br />
5. Fifth stage<br />
6. Sixth stage<br />
7. Seventh stage<br />
8. Eight stage<br />
9. Ninth stage<br />
Single and Three phase Models - <strong>ACDC</strong> <strong>Surge</strong> <strong>Protector</strong>s type - <strong>PI</strong> <strong>780</strong> <strong>Red</strong> <strong>Series</strong><br />
<strong>Type</strong><br />
<strong>Type</strong> - <strong>PI</strong> <strong>780</strong> 1/1-RS x 3<br />
Order Code<br />
800.135-1/1 x 3<br />
Total <strong>Surge</strong> Cur.<br />
315kA(8/20μs) or 45kA(10/350μs)<br />
Dimension (WxDxHmm)<br />
82x216x70<br />
Weight (kg)<br />
1,41<br />
MULTI-STAGE SURGE PROTECTION<br />
LIN for parallel application<br />
LIN for series application<br />
Bi-direct.<br />
Filter<br />
NIN<br />
<strong>ACDC</strong> <strong>Surge</strong> <strong>Protector</strong> <strong>Type</strong>-<strong>PI</strong> <strong>780</strong> <strong>Red</strong> <strong>Series</strong><br />
<strong>Surge</strong> Cur. 80kA (8/20μs) or 12,5kA (10/350μs)<br />
L=0.7mH; Imax=up to 100A<br />
<strong>Surge</strong> Cur. 25kA (8/20μs) U ltimate protection stage. He switch-off the circuits breaker<br />
install upstream, if the pick voltage > 52 0VDC appears on<br />
the output. C ircuits breaker should be < 250A gl/gG.<br />
TVS Limiter 500A (8/20μs) ;<br />
Typical response < 1ns ec (nanosecond)<br />
L=0.7mH; Imax=up to 100A<br />
L=0.7mH<br />
<strong>Surge</strong> Cur. 80kA (8/20μs) or 12,5kA (10/350μs)<br />
<strong>Type</strong><br />
<strong>Type</strong> - <strong>PI</strong> <strong>780</strong> 3/3-M-RS<br />
Order Code<br />
800.135-3/3-M<br />
Total <strong>Surge</strong> Cur.<br />
315kA(8/20μs) or 45kA(10/350μs)<br />
Dimension (WxDxHmm)<br />
250x250x150<br />
Weight (kg)<br />
5,1<br />
Bi-directional<br />
Filter<br />
(No back EMF effect)<br />
<strong>Type</strong><br />
<strong>Type</strong> - <strong>PI</strong> <strong>780</strong> 3/3-MCB-RS<br />
Order Code<br />
800.135-3/3-MCB<br />
Total <strong>Surge</strong> Cur.<br />
315kA(8/20μs) or 45kA(10/350μs)<br />
Dimension (WxDxHmm)<br />
300X250X150<br />
Weight (kg)<br />
<strong>acdc</strong>-<strong>dcac</strong>@<strong>acdc</strong>-<strong>dcac</strong>.<strong>eu</strong> <strong>ACDC</strong> DCAC Dane Krapcev no.2/1, 1000-Skopje, Macedonia Phone: 389 2 3216 988; Fax: 389 2 3216 993<br />
C C<br />
C<br />
Var. Var.<br />
C<br />
Thermal<br />
Cut-Off<br />
GTD<br />
Control<br />
GTD<br />
Thermal<br />
Cut-Off<br />
7,1<br />
<strong>Red</strong> Yellow Green<br />
Control<br />
GTD<br />
TVS<br />
Limiter<br />
LOUT<br />
NOUT<br />
without filtering GND IN<br />
GND IN for ground filtering for ground filtering GND OUT<br />
Function Technology<br />
Bi-directional filtering (L-N);<br />
Front signal edge reduction;<br />
Suppression signal shape<br />
(L-N) , 8/20μs or 10/350μs Bi-directional filtering (L-N);<br />
Front signal edge reduction;<br />
Suppression signal shape<br />
(L-N) , 8/20μs Long term signal suppression<br />
from 1μs to 2 sec.<br />
High speed efficiency<br />
signal suppression<br />
Bi-directional filtering ( N-L); Front signal edge reduction;<br />
Ground filtering<br />
Suppression signal shape<br />
( N-Gnd ) , 8/20μs or 10/350μs Nano Crystalline Core<br />
(L-C configuration)<br />
Varistor with thermal cut-off;<br />
Control Gas Tube Discharge<br />
Nano Crystalline Core<br />
(L-C configuration)<br />
Varistor with thermal cut-off<br />
Control Gas Tube Discharge<br />
Transient Voltage<br />
Suppressor<br />
Nano Crystalline Core<br />
(L-C configuration)<br />
Nano Crystalline Core<br />
(L-C configuration)<br />
Control Gas Tube Discharge