LAN Cable 1200<br />

Cable structure<br />

Inner conductor diameter:<br />

Conductor material:<br />

Core insulation:<br />

Core colours:<br />

Shielding 1<br />

Screen over str<strong>and</strong>ing element:<br />

Screen 1 over str<strong>and</strong>ing:<br />

Screen 2 over str<strong>and</strong>ing:<br />

Outer sheath material:<br />

Outer Ø<br />

Outer sheath colour:<br />

Electrical <strong>data</strong><br />

Characteristic impedance:<br />

Loop resistance:<br />

Mutual capacitance:<br />

Rel. propagation velocity:<br />

Typical values<br />

Frequency<br />

Attenuation<br />

Next<br />

ACR<br />

Technical <strong>data</strong><br />

(MHz)<br />

(dB/100m)<br />

(db)<br />

(db)<br />

Weight:<br />

Min. bending radius for laying:<br />

Operating temperature range min.:<br />

Operating temperature range max.:<br />

Caloric load, approx. value:<br />

Copper weight:<br />

S-STP 4x2xAWG 22/1 FRNC<br />

0,64 mm<br />

Copper, bare<br />

Foam-skin-PE<br />

wh/bu, wh/og, wh/gn, wh/bn<br />

-<br />

Polyester foil, aluminium-lined<br />

Cu braid<br />

-<br />

FRNC<br />

approx. 7,7 mm<br />

Blue similar to RAL 5015<br />

100 Ohm ± 15 ohm at 1 to 100 MHz<br />

100 Ohm ± 20 ohm at 101 to 1200 MHz<br />

120 Ohm/km max.<br />

43,00 nF/km nom.<br />

79 %<br />

10<br />

4,9<br />

100,0<br />

95,1<br />

16<br />

6,3<br />

100,0<br />

93,7<br />

66,00 kg/km<br />

72 mm<br />

-20°C<br />

+60°C<br />

0,7 MJ/m<br />

41,00 kg/km<br />

62,5<br />

12,7<br />

95,0<br />

82,3<br />

100<br />

16,3<br />

93,0<br />

76,7<br />

200<br />

23,5<br />

90,0<br />

66,5<br />

Norms<br />

Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category8,<br />

Flame-retardant acc. to IEC60332-3, Smoke density acc. to IEC61034, Halogen-free acc.<br />

to 60754-2, Corrosiveness acc. to EN50267-2-3<br />

<br />

300<br />

29,4<br />

87,0<br />

57,6<br />

600<br />

42,8<br />

81,0<br />

38,2<br />

1000<br />

53,0<br />

78,0<br />

25,0<br />

S-STP<br />

Application<br />

HELUKAT ® 1200 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />

performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />

E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />

suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />

Part no.<br />

Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />

81699, S-STP 4x2xAWG 22/1 FRNC<br />

77<br />

1200<br />

59,0<br />

77,0<br />

18,0