All HELUKATÚ data cables and wires comply with the ... - Eurocabos
All HELUKATÚ data cables and wires comply with the ... - Eurocabos
All HELUKATÚ data cables and wires comply with the ... - Eurocabos
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>and</strong> category 8 according actual draft.<br />
54
Contents Copper Data Cables<br />
Description<br />
HELUKAT 155 UTP solid ..............................................................................................................................<br />
HELUKAT 155 UTP solid, UL ........................................................................................................................<br />
HELUKAT 300 UTP UL ..................................................................................................................................<br />
HELUKAT 100 UTP flex ................................................................................................................................<br />
HELUKAT 155 FTP solid ...............................................................................................................................<br />
HELUKAT 100 FTP flex ................................................................................................................................<br />
HELUKAT 200 FTP flex, UL ..........................................................................................................................<br />
HELUKAT 200 S-FTP solid ...........................................................................................................................<br />
HELUKAT 200 S-FTP duplex solid ...............................................................................................................<br />
HELUKAT 200 S-FTP flex .............................................................................................................................<br />
HELUKAT 300 U-STP flex, UL .......................................................................................................................<br />
HELUKAT 450 S-STP solid ............................................................................................................................<br />
HELUKAT 450 S-STP duplex solid ...............................................................................................................<br />
HELUKAT 600 S-STP solid ............................................................................................................................<br />
HELUKAT 600 S-STP duplex solid ...............................................................................................................<br />
HELUKAT 600 S-STP flex .............................................................................................................................<br />
HELUKAT 600A S-STP solid outdoor ...........................................................................................................<br />
HELUKAT 600E S-STP solid, direct burial ....................................................................................................<br />
HELUKAT 600AE S-STP solid direct burial ...................................................................................................<br />
HELUKAT 900 S-STP solid ............................................................................................................................<br />
HELUKAT 900 S-STP duplex solid ...............................................................................................................<br />
HELUKAT 1200 S-STP solid ..........................................................................................................................<br />
HELUKAT 1200 S-STP duplex solid .............................................................................................................<br />
HELUKAT 1500 S-STP solid ..........................................................................................................................<br />
HELUKAT 1500 S-STP duplex solid .............................................................................................................<br />
Twinaxial cable, indoor or outdoor ...........................................................................................................<br />
IBM type 1A, type 1A mini, type 6A ...........................................................................................................<br />
E<strong>the</strong>rnet Cheapernet Cable, Yellow Cable, Transceiver Cable .................................................................<br />
HF <strong>cables</strong> radiating, HDPE .........................................................................................................................<br />
HF <strong>cables</strong> radiating, FRNC .........................................................................................................................<br />
HF <strong>cables</strong>, flexible ......................................................................................................................................<br />
55<br />
Page<br />
56<br />
57<br />
58<br />
59<br />
60<br />
61<br />
62<br />
63<br />
64<br />
65<br />
66<br />
67<br />
68<br />
69<br />
70<br />
71<br />
72<br />
73<br />
74<br />
75<br />
76<br />
77<br />
78<br />
79<br />
80<br />
81<br />
82<br />
83<br />
84<br />
85<br />
86
LAN Cable 155<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
UTP 4x2xAWG 24/1 PVC<br />
0,51 mm<br />
Copper, bare<br />
PE<br />
whbu/bu, whog/og, whgn/gn, whbn/bn<br />
-<br />
-<br />
-<br />
-<br />
PVC<br />
approx. 4,9 mm<br />
Grey<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
190 Ohm/km max.<br />
50,0 nF/km nom.<br />
66 %<br />
10<br />
6,3<br />
50,3<br />
44,0<br />
26,0 kg/km<br />
40 mm<br />
-20°C<br />
+60°C<br />
0,4 MJ/m<br />
17,80 kg/km<br />
16<br />
8,0<br />
47,3<br />
39,3<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category5e<br />
Application<br />
HELUKAT ® 155 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Fast E<strong>the</strong>rnet, E<strong>the</strong>rnet,<br />
ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly suited<br />
for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
80053, UTP 4x2xAWG24/1 PVC<br />
56<br />
62,5<br />
16,5<br />
38,4<br />
21,9<br />
<br />
100<br />
21,3<br />
35,3<br />
14,0<br />
155<br />
26,8<br />
33,0<br />
6,2<br />
UTP
LAN Cable 155<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(db/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
UTP 4x2xAWG 24/1 PVC, UL<br />
0,53 mm<br />
Copper, bare<br />
PE<br />
whbu/bu, whog/og, whgn/gn, whbn/bn<br />
-<br />
-<br />
-<br />
-<br />
PVC<br />
approx. 5,2 mm<br />
Grey<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
190 Ohm/km max.<br />
50,0 nF/km nom.<br />
66 %<br />
10<br />
6,1<br />
65,0<br />
58,9<br />
35,00 kg/km<br />
42 mm<br />
-20°C<br />
+60°C<br />
0,43 MJ/m<br />
17,00 kg/km<br />
16<br />
7,7<br />
63,0<br />
55,3<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category5e,<br />
Flame-retardant acc. to IEC60332-1, Smoke density acc. to IEC61034, CMX 444<br />
62,5<br />
15,2<br />
53,0<br />
37,8<br />
<br />
100<br />
19,9<br />
40,0<br />
20,1<br />
155<br />
22,7<br />
37,0<br />
14,3<br />
UTP UL<br />
Application<br />
HELUKAT ® 155 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction. This type is certified according<br />
UL because of <strong>the</strong> special PVC jacket<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
802171, UTP 4x2xAWG24/1 PVC UL<br />
57
LAN Cable 300<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(db/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
UTP 4x2xAWG 24/1 PVC, UL<br />
0,55 mm<br />
Copper, bare<br />
PE<br />
whbu/bu, whog/og, whgn/gn, whbn/bn<br />
-<br />
-<br />
-<br />
-<br />
PVC<br />
approx. 6,8 mm<br />
Grey<br />
100 Ohm ± 20 ohm at 101 to 155 MHz<br />
190 Ohm/km max.<br />
50,0 nF/km nom.<br />
67 %<br />
10<br />
5,6<br />
72,0<br />
66,4<br />
46,00 kg/km<br />
55 mm<br />
-20°C<br />
+60°C<br />
0,68 MJ/m<br />
20,00 kg/km<br />
16<br />
7,0<br />
70,0<br />
63,0<br />
62,5<br />
14,3<br />
65,0<br />
50,7<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category6,<br />
Flame-retardant acc. to IEC60332-1, Smoke density acc. to IEC61034, CMX 444<br />
100<br />
18,2<br />
63,0<br />
44,8<br />
<br />
155<br />
22,9<br />
60,0<br />
37,1<br />
200<br />
26,0<br />
57,0<br />
31,0<br />
300<br />
32,5<br />
55,0<br />
22,5<br />
UTP UL<br />
Application<br />
HELUKAT ® 300 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction. This type is certified according<br />
UL because of <strong>the</strong> special PVC jacket<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
802172, UTP 4x2xAWG24/1 PVC UL<br />
58
LAN-Cable 100<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/10m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
UTP 4x2xAWG 26/7 PVC<br />
0,48 mm<br />
Copper, bare<br />
PO<br />
whbu/bu, whog/og, whgn/gn, whbn/bn<br />
-<br />
-<br />
-<br />
-<br />
PVC<br />
approx. 4,5 mm<br />
Grey similar to RAL 7035<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
290 Ohm/km max.<br />
50,0 nF/km nom.<br />
74 %<br />
10<br />
0,9<br />
53,0<br />
52,1<br />
17,00 kg/km<br />
35 mm<br />
-20°C<br />
+60°C<br />
0,527 MJ/m<br />
11,00 kg/km<br />
16<br />
1,2<br />
50,0<br />
48,8<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category5<br />
<br />
62,5<br />
2,4<br />
41,0<br />
38,6<br />
100<br />
3,1<br />
38,0<br />
34,9<br />
UTP flex<br />
Application<br />
HELUKAT ® 100 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary level of a network as patch <strong>cables</strong> <strong>and</strong> connection <strong>cables</strong>. They are characterized<br />
by large performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, <strong>the</strong> HELUKAT ® 100<br />
series can be manufactured quickly <strong>and</strong> easily <strong>with</strong> all common RJ45 plugs.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
80055, UTP 4x2xAWG 26/7 PVC<br />
59
LAN Cable 155<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
FTP 4x2xAWG 24/1 PVC<br />
0,51 mm<br />
Copper, bare<br />
PE<br />
whbu/bu, whog/og, whgn/gn, whbn/bn<br />
Polyester foil over str<strong>and</strong>ed bundle<br />
-<br />
Polyester foil, aluminium-lined<br />
-<br />
PVC<br />
approx. 5,9 mm<br />
Yellow similar to RAL 1021<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
170 Ohm/km max.<br />
50,0 nF/km nom.<br />
69 %<br />
10<br />
5,9<br />
59,0<br />
53,1<br />
40,0 kg/km<br />
48 mm<br />
-20°C<br />
+60°C<br />
0,4 MJ/m<br />
18,0 kg/km<br />
16<br />
7,6<br />
53,0<br />
45,4<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category5e<br />
Application<br />
HELUKAT ® 155 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Fast E<strong>the</strong>rnet, E<strong>the</strong>rnet,<br />
ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly suited<br />
for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
80043, FTP 4x2xAWG24/1 PVC<br />
60<br />
62,5<br />
15,7<br />
44,0<br />
28,3<br />
<br />
100<br />
20,3<br />
40,0<br />
19,7<br />
155<br />
22,0<br />
40,0<br />
18,0<br />
FTP
LAN Cable 100<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/10m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
FTP 4x2xAWG 26/7 FRNC<br />
0,48 mm<br />
Copper, bare<br />
PO<br />
whbu/bu, whog/og, whgn/gn, whbn/bn<br />
Polyester foil over str<strong>and</strong>ed bundle<br />
-<br />
Polyester foil, aluminium-lined<br />
-<br />
FRNC<br />
approx. 5,7 mm<br />
Grey similar to RAL 7035<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
290 Ohm/km max.<br />
50,0 nF/km nom.<br />
74 %<br />
10<br />
0,9<br />
58,0<br />
57,1<br />
31,00 kg/km<br />
40 mm<br />
-20°C<br />
+60°C<br />
0,527 MJ/m<br />
14,00 kg/km<br />
16<br />
1,2<br />
56,0<br />
54,8<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category5,<br />
Flame-retardant acc. to IEC60332-1, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
62,5<br />
2,4<br />
45,0<br />
42,6<br />
100<br />
2,9<br />
43,0<br />
40,1<br />
FTP flex<br />
Application<br />
HELUKAT ® 100 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary level of a network as patch <strong>cables</strong> <strong>and</strong> connection <strong>cables</strong>. They are characterized<br />
by large performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, <strong>the</strong> HELUKAT ® 100<br />
series can be manufactured quickly <strong>and</strong> easily <strong>with</strong> all common RJ45 plugs.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
81278, FTP 4x2xAWG 26/7 FRNC<br />
61
LAN Cables 200<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(db/10m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
FTP 4x2xAWG 26/7 PVC, UL<br />
0,48 mm<br />
Copper, bare<br />
PE<br />
whbu/bu, whog/og, whgn/gn, whbn/bn<br />
-<br />
-<br />
Polyester foil, aluminium-lined<br />
-<br />
PVC<br />
approx. 5,4 mm<br />
Grey similar to RAL 7035<br />
100 Ohm ± 20 ohm at 101 to 155 MHz<br />
290 Ohm/km max.<br />
50,0 nF/km nom.<br />
67 %<br />
10<br />
0,9<br />
62,0<br />
61,1<br />
30,00 kg/km<br />
44 mm<br />
-20°C<br />
+60°C<br />
0,40 MJ/m<br />
15,00 kg/km<br />
16<br />
1,2<br />
60,0<br />
58,8<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category5e,<br />
Flame-retardant acc. to IEC60332-1, Smoke density acc. to IEC61034, CMX 444<br />
62,5<br />
2,4<br />
50,0<br />
47,6<br />
<br />
100<br />
3,1<br />
48,0<br />
44,9<br />
FTP Flex, UL<br />
Application<br />
HELUKAT ® 200 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary level of a network as patch <strong>cables</strong> <strong>and</strong> connection <strong>cables</strong>. They are characterized<br />
by large performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet,<br />
Fast E<strong>the</strong>rnet, E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, <strong>the</strong><br />
HELUKAT ® 200 series can be manufactured quickly <strong>and</strong> easily <strong>with</strong> all common RJ45 plugs. This type is certified according UL because<br />
of <strong>the</strong> special PVC jacket.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
802173, FTP 4x2xAWG26/7 PVC UL<br />
62<br />
200<br />
3,9<br />
45,0<br />
41,1
LAN-Cable 200<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-FTP 4x2xAWG 24/1 PVC or FRNC<br />
0,51 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
whbu/bu, whog/og, whgn/gn, whbn/bn<br />
Polyester foil over str<strong>and</strong>ed bundle<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
PVC / FRNC<br />
approx. 6,0 mm / approx. 6,0 mm<br />
Grey similar to RAL 7035<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
185 Ohm/km max.<br />
48,0 nF/km nom.<br />
74 %<br />
10<br />
5,6<br />
62,0<br />
56,4<br />
16<br />
7,2<br />
59,0<br />
51,8<br />
50,0 kg/km<br />
52 mm<br />
-20°C<br />
+60°C<br />
0,60 MJ/m / 0,48 MJ/m<br />
28,00 kg/km<br />
62,5<br />
14,4<br />
50,0<br />
35,6<br />
Norms<br />
81610:<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category5e<br />
81609:<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category5e,<br />
Flame-retardant acc. to IEC60332-3, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
100<br />
18,2<br />
46,0<br />
27,8<br />
200<br />
25,9<br />
40,0<br />
14,6<br />
S-FTP<br />
Application<br />
HELUKAT ® 200 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
81610, S-FTP 4x2xAWG 24/1 PVC<br />
63<br />
81609, S-FTP 4x2xAWG 24/1 FRNC
LAN Cable 200<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Cable dimensions:<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-FTP 2x(4x2xAWG 24/1) FRNC<br />
0,51 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
whbu/bu, whog/og, whgn/gn, whbn/bn<br />
Polyester foil over str<strong>and</strong>ed bundle<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
FRNC<br />
approx. 6,0 mm x 12,5 mm<br />
Green similar to RAL 6018<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
185 Ohm/km max.<br />
48,0 nF/km nom.<br />
74 %<br />
10<br />
5,6<br />
62,0<br />
56,4<br />
100,0 kg/km<br />
52 mm<br />
-20°C<br />
+60°C<br />
0,96 MJ/m<br />
56,00 kg/km<br />
16<br />
7,2<br />
59,0<br />
51,8<br />
62,5<br />
14,4<br />
50,0<br />
35,6<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category5e,<br />
Flame-retardant acc. to IEC60332-3, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
100<br />
18,2<br />
46,0<br />
27,8<br />
S-FTP duplex<br />
Application<br />
HELUKAT ® 200 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
81123, S-FTP 2x(4x2xAWG 24/1) FRNC<br />
64<br />
200<br />
25,9<br />
40,0<br />
14,6
LAN Cable 200<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/10m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-FTP 4x2xAWG 26/7 FRNC<br />
0,48 mm<br />
Copper, bare<br />
PO<br />
whbu/bu, whog/og, whgn/gn, whbn/bn<br />
Polyester foil over str<strong>and</strong>ed bundle<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
FRNC<br />
approx. 5,3 mm<br />
Grey similar to RAL 7035<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
260 Ohm/km max.<br />
47,0 nF/km nom.<br />
69 %<br />
10<br />
0,8<br />
58,0<br />
57,2<br />
35,00 kg/km<br />
46 mm<br />
-20°C<br />
+60°C<br />
0,543 MJ/m<br />
24,00 kg/km<br />
16<br />
1,1<br />
56,0<br />
54,9<br />
62,5<br />
2,4<br />
45,0<br />
42,6<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category5e,<br />
Flame-retardant acc. to IEC60332-1, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
100<br />
2,9<br />
43,0<br />
40,1<br />
200<br />
4,3<br />
37,0<br />
32,7<br />
S-FTP flex<br />
Application<br />
HELUKAT ® 200 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary level of a network as patch <strong>cables</strong> <strong>and</strong> connection <strong>cables</strong>. They are characterized<br />
by large performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet,<br />
Fast E<strong>the</strong>rnet, E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, <strong>the</strong><br />
HELUKAT ® 200 series can be manufactured quickly <strong>and</strong> easily <strong>with</strong> all common RJ45 plugs.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
81254, S-FTP 4x2xAWG 26/7 FRNC<br />
65
LAN Cable 300<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(db/10m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-UTP 4x2xAWG 26/7 PVC, UL<br />
0,48 mm<br />
Copper, tinned<br />
Foam-skin-PE<br />
whbu/bu, whog/og, whgn/gn, whbn/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Polyester foil, aluminium-lined<br />
-<br />
PVC<br />
approx. 5,9 mm<br />
Grey similar to RAL 7035<br />
100 Ohm ± 20 ohm at 101 to 155 MHz<br />
290 Ohm/km max.<br />
45,00 nF/km nom.<br />
77 %<br />
10<br />
0,9<br />
90,0<br />
89,1<br />
37,00 kg/km<br />
48 mm<br />
-20°C<br />
+60°C<br />
0,41 MJ/m<br />
20,00 kg/km<br />
16<br />
1,1<br />
88,0<br />
86,9<br />
62,5<br />
2,2<br />
83,0<br />
80,8<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category6,<br />
Flame-retardant acc. to IEC60332-1, Smoke density acc. to IEC61034, CMX 444<br />
<br />
100<br />
2,7<br />
80,0<br />
77,3<br />
200<br />
3,9<br />
76,0<br />
72,1<br />
U-STP, UL<br />
Application<br />
HELUKAT ® 300 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary level of a network as patch <strong>cables</strong> <strong>and</strong> connection <strong>cables</strong>. They are characterized<br />
by large performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet,<br />
Fast E<strong>the</strong>rnet, E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, <strong>the</strong><br />
HELUKAT ® 300 series can be manufactured quickly <strong>and</strong> easily <strong>with</strong> all common RJ45 plugs. This type is certified according UL because<br />
of <strong>the</strong> special PVC jacket.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
802174, U-STP 4x2xAWG 26/7 PVC<br />
66<br />
300<br />
4,7<br />
73,0<br />
68,3
LAN Cable 450<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 4x2xAWG 24/1 FRNC<br />
0,52 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Polyester foil, aluminium-lined<br />
-<br />
FRNC<br />
approx. 7,4 mm<br />
Green similar to RAL 6018<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 450 MHz<br />
146 Ohm/km max.<br />
43,0 nF/km nom.<br />
79 %<br />
10<br />
5,4<br />
100,0<br />
94,6<br />
50,00 kg/km<br />
59 mm<br />
-20°C<br />
+60°C<br />
0,57 MJ/m<br />
24,00 kg/km<br />
16<br />
7,0<br />
100,0<br />
93,0<br />
62,5<br />
13,8<br />
95,8<br />
82,0<br />
100<br />
17,6<br />
94,5<br />
76,9<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category6,<br />
Flame-retardant acc. to IEC60332-3, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
200<br />
26,0<br />
91,0<br />
65,0<br />
300<br />
34,0<br />
87,0<br />
53,0<br />
450<br />
38,5<br />
84,3<br />
45,8<br />
S-STP<br />
Application<br />
HELUKAT ® 450 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
82501, S-STP 4x2xAWG 24/1 FRNC<br />
67
LAN Cable 450<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Cable dimensions:<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 2x(4x2xAWG 24/1) FRNC<br />
0,52 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Polyester foil, aluminium-lined<br />
-<br />
FRNC<br />
approx. 7,4 mm x 15,0 mm<br />
Green similar to RAL 6018<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 450 MHz<br />
146 Ohm/km max.<br />
43,0 nF/km nom.<br />
79 %<br />
10<br />
5,4<br />
100,0<br />
94,6<br />
16<br />
7,0<br />
100,0<br />
93,0<br />
100,00 kg/km<br />
59 mm<br />
-20°C<br />
+60°C<br />
1,14 MJ/m<br />
48,00 kg/km<br />
62,5<br />
13,8<br />
95,8<br />
82,0<br />
100<br />
17,6<br />
94,5<br />
76,9<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category6,<br />
Flame-retardant acc. to IEC60332-3, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
200<br />
26,0<br />
91,0<br />
65,0<br />
300<br />
34,0<br />
87,0<br />
53,0<br />
S-STP duplex<br />
Application<br />
HELUKAT ® 450 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
82502, S-STP 2x(4x2xAWG 24/1) FRNC<br />
68<br />
450<br />
38,5<br />
84,3<br />
45,8
LAN Cable 600<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 4x2xAWG 23/1 FRNC<br />
0,56 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
-<br />
FRNC<br />
approx. 7,5 mm<br />
Blue Lilac similar to RAL 4005<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 600 MHz<br />
130 Ohm/km max.<br />
43,0 nF/km nom.<br />
79 %<br />
10<br />
5,6<br />
100,0<br />
94,4<br />
60,00 kg/km<br />
60 mm<br />
-20°C<br />
+60°C<br />
0,6 MJ/m<br />
34,00 kg/km<br />
16<br />
7,1<br />
100,0<br />
92,9<br />
62,5<br />
13,9<br />
96,0<br />
82,1<br />
100<br />
17,5<br />
94,0<br />
76,5<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category7,<br />
Flame-retardant acc. to IEC60332-3, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
200<br />
25,2<br />
88,0<br />
62,8<br />
300<br />
32,1<br />
84,0<br />
51,9<br />
600<br />
44,9<br />
73,0<br />
28,1<br />
S-STP<br />
Application<br />
HELUKAT ® 600 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
80810, S-STP 4x2xAWG 23/1 FRNC<br />
69
LAN Cable 600<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Cable dimensions:<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 2x(4x2xAWG 23/1) FRNC<br />
0,56 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
-<br />
FRNC<br />
approx. 7,5 mm x 16,0 mm<br />
Blue Lilac similar to RAL 4005<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 600 MHz<br />
130 Ohm/km max.<br />
43,0 nF/km nom.<br />
79 %<br />
10<br />
5,6<br />
100,0<br />
94,4<br />
16<br />
7,1<br />
100,0<br />
92,9<br />
120,00 kg/km<br />
60 mm<br />
-20°C<br />
+60°C<br />
1,2 MJ/m<br />
68,00 kg/km<br />
62,5<br />
13,9<br />
96,0<br />
82,1<br />
100<br />
17,5<br />
94,0<br />
76,5<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category7,<br />
Flame-retardant acc. to IEC60332-3, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
200<br />
25,2<br />
88,0<br />
62,8<br />
300<br />
32,1<br />
84,0<br />
51,9<br />
S-STP duplex<br />
Application<br />
HELUKAT ® 600 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
81446, S-STP 2x(4x2xAWG 23/1) FRNC<br />
70<br />
600<br />
44,9<br />
73,0<br />
28,1
LAN Cable 600<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/10m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 4x2xAWG 26/7 FRNC<br />
0,48 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
-<br />
FRNC<br />
approx. 5,9 mm<br />
Grey similar to RAL 7035<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 600 MHz<br />
264 Ohm/km max.<br />
45,0 nF/km nom.<br />
77 %<br />
10<br />
0,8<br />
96,0<br />
95,2<br />
42,00 kg/km<br />
55 mm<br />
-20°C<br />
+60°C<br />
0,47 MJ/m<br />
22,0 kg/km<br />
16<br />
1,0<br />
96,0<br />
95,0<br />
62,5<br />
2,0<br />
95,0<br />
93,0<br />
100<br />
2,6<br />
94,0<br />
91,4<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category7,<br />
Flame-retardant acc. to IEC60332-1, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
200<br />
4,0<br />
88,0<br />
84,0<br />
300<br />
4,9<br />
86,0<br />
81,1<br />
S-STP flex<br />
Application<br />
HELUKAT ® 600 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary level of a network as patch <strong>cables</strong> <strong>and</strong> connection <strong>cables</strong>. They are characterized<br />
by large performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet,<br />
Fast E<strong>the</strong>rnet, E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. With its optimized construction, <strong>the</strong><br />
HELUKAT ® 600 series can be manufactured quickly <strong>and</strong> easily <strong>with</strong> all common RJ45 plugs.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
80294, S-STP 4x2xAWG 26/7 FRNC<br />
71<br />
600<br />
6,3<br />
80,0<br />
73,7
LAN Cable Outdoor 600A<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Inner sheath material:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 4x2xAWG 23/1 PVC/PVC<br />
0,58 mm<br />
Copper, bare<br />
PO<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
-<br />
PVC<br />
PVC<br />
approx. 11,8 mm<br />
Black similar to RAL 9005<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 600 MHz<br />
160 Ohm/km max.<br />
43,0 nF/km nom.<br />
79 %<br />
10<br />
5,8<br />
85,0<br />
79,2<br />
16<br />
7,4<br />
85,0<br />
77,6<br />
153,00 kg/km<br />
95 mm<br />
-30°C<br />
+70°C<br />
2,62 MJ/m<br />
34,00 kg/km<br />
62,5<br />
14,6<br />
85,0<br />
70,4<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category7,<br />
Flame-retardant acc. to IEC60332-1, Smoke density acc. to IEC61034<br />
100<br />
18,4<br />
85,0<br />
66,6<br />
<br />
200<br />
26,2<br />
83,0<br />
56,8<br />
300<br />
32,1<br />
80,0<br />
47,9<br />
S-STP PVC/PVC<br />
Application<br />
HELUKAT ® 600 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT ® 600A <strong>with</strong> a double PVC jacket<br />
is constructed especially for outdoor applications like laying at house walls or in cable lines.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
801147, S-STP 4x2xAWG 23/1 PVC/PVC<br />
72<br />
600<br />
49,0<br />
80,0<br />
31,0
LAN Cable Direct Burial 600E<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 4x2xAWG 23/1 direct burial<br />
0,58 mm<br />
Copper, bare<br />
PO<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
-<br />
PVC<br />
approx. 9,8 mm<br />
Black<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 600 MHz<br />
150 Ohm/km max.<br />
42,00 nF/km nom.<br />
79 %<br />
10<br />
5,8<br />
85,0<br />
79,2<br />
16<br />
7,4<br />
85,0<br />
77,6<br />
102,00 kg/km<br />
100 mm<br />
-45°C<br />
+65°C<br />
1,40 MJ/m<br />
34,00 kg/km<br />
62,5<br />
14,6<br />
85,0<br />
70,4<br />
100<br />
18,4<br />
85,0<br />
66,6<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category7,<br />
Flame-retardant acc. to IEC60332-1, Smoke density acc. to IEC61034, UL 1581 VW-1<br />
<br />
200<br />
26,2<br />
83,0<br />
56,8<br />
300<br />
32,1<br />
80,0<br />
47,9<br />
S-STP PVC<br />
Application<br />
HELUKAT ® 600 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT ® 600E <strong>with</strong> a cold resistant<br />
PVC jacket is constructed especially for outdoor applications like laying at house walls or direct burial.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
802167, S-STP 4x2xAWG23/1 PVC<br />
73<br />
600<br />
49,0<br />
80,0<br />
31,0
LAN Cable armoured 600AE<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Inner sheath material:<br />
Armouring:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 4x2xAWG 23/1 FRNC/PVC<br />
0,58 mm<br />
Copper, bare<br />
PO<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
-<br />
FRNC<br />
Steel shaft<br />
PVC<br />
approx. 12,0 mm<br />
Black<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 600 MHz<br />
150 Ohm/km max.<br />
43,00 nF/km nom.<br />
79 %<br />
10<br />
5,8<br />
85,0<br />
79,2<br />
16<br />
7,4<br />
85,0<br />
77,6<br />
154,00 kg/km<br />
330 mm<br />
-15°C<br />
+50°C<br />
2,30 MJ/m<br />
34,00 kg/km<br />
62,5<br />
14,6<br />
85,0<br />
70,4<br />
100<br />
18,4<br />
85,0<br />
66,6<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category7,<br />
Flame-retardant acc. to IEC60332-1, Smoke density acc. to IEC61034, UL 1581 VW-1<br />
<br />
200<br />
26,2<br />
83,0<br />
56,8<br />
S-STP FRNC/PVC<br />
Application<br />
HELUKAT ® 600 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT ® 600AE <strong>with</strong> a FRNC/PVC<br />
double jacket <strong>and</strong> <strong>the</strong> rodent protection is constructed especially for outdoor <strong>and</strong> direct burial applications.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
802168, S-STP 4x2xAWG 23/1 FRNC/PVC<br />
74<br />
300<br />
32,1<br />
80,0<br />
47,9<br />
600<br />
49,0<br />
80,0<br />
31,0
LAN Cable 900<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 4x2xAWG 23/1 FRNC<br />
0,58 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
-<br />
FRNC<br />
approx. 7,8 mm<br />
Blue Lilac similar to RAL 4005<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 900 MHz<br />
146 Ohm/km max.<br />
43,0 nF/km nom.<br />
79 %<br />
10<br />
5,0<br />
100,0<br />
95,0<br />
64,00 kg/km<br />
63 mm<br />
-20°C<br />
+60°C<br />
0,6 MJ/m<br />
36,00 kg/km<br />
16<br />
6,5<br />
100,0<br />
93,5<br />
62,5<br />
13,2<br />
100,0<br />
86,8<br />
100<br />
16,8<br />
99,0<br />
82,2<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category7,<br />
Flame-retardant acc. to IEC60332-3, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
200<br />
25,0<br />
96,0<br />
71,0<br />
600<br />
42,5<br />
91,0<br />
48,5<br />
900<br />
55,0<br />
86,0<br />
31,0<br />
S-STP<br />
Application<br />
HELUKAT ® 900 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
800086, S-STP 4x2xAWG 23/1 FRNC<br />
75
LAN Cable 900<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Cable dimensions:<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 2x(4x2xAWG 23/1) FRNC<br />
0,58 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
-<br />
FRNC<br />
approx. 7,8 mm x 17,0 mm<br />
Blue Lilac similar to RAL 4005<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 900 MHz<br />
146 Ohm/km max.<br />
43,0 nF/km nom.<br />
79 %<br />
10<br />
5,0<br />
100,0<br />
95,0<br />
16<br />
6,5<br />
100,0<br />
93,5<br />
128,00 kg/km<br />
63 mm<br />
-20°C<br />
+60°C<br />
1,2 MJ/m<br />
72,00 kg/km<br />
62,5<br />
13,2<br />
100,0<br />
86,8<br />
100<br />
16,8<br />
99,0<br />
82,2<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category7,<br />
Flame-retardant acc. to IEC60332-3, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
200<br />
25,0<br />
96,0<br />
71,0<br />
600<br />
42,5<br />
91,0<br />
48,5<br />
S-STP duplex<br />
Application<br />
HELUKAT ® 900 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
800087, S-STP 2x(4x2xAWG 23/1) FRNC<br />
76<br />
900<br />
55,0<br />
86,0<br />
31,0
LAN Cable 1200<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 4x2xAWG 22/1 FRNC<br />
0,64 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
-<br />
FRNC<br />
approx. 7,7 mm<br />
Blue similar to RAL 5015<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 1200 MHz<br />
120 Ohm/km max.<br />
43,00 nF/km nom.<br />
79 %<br />
10<br />
4,9<br />
100,0<br />
95,1<br />
16<br />
6,3<br />
100,0<br />
93,7<br />
66,00 kg/km<br />
72 mm<br />
-20°C<br />
+60°C<br />
0,7 MJ/m<br />
41,00 kg/km<br />
62,5<br />
12,7<br />
95,0<br />
82,3<br />
100<br />
16,3<br />
93,0<br />
76,7<br />
200<br />
23,5<br />
90,0<br />
66,5<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category8,<br />
Flame-retardant acc. to IEC60332-3, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
300<br />
29,4<br />
87,0<br />
57,6<br />
600<br />
42,8<br />
81,0<br />
38,2<br />
1000<br />
53,0<br />
78,0<br />
25,0<br />
S-STP<br />
Application<br />
HELUKAT ® 1200 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
81699, S-STP 4x2xAWG 22/1 FRNC<br />
77<br />
1200<br />
59,0<br />
77,0<br />
18,0
LAN Cable 1200<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Cable dimensions:<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 2x(4x2xAWG 22/1) FRNC<br />
0,64 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
-<br />
FRNC<br />
approx. 7,7 mm x 16,5 mm<br />
Blue similar to RAL 5015<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 1200 MHz<br />
120 Ohm/km max.<br />
43,00 nF/km nom.<br />
79 %<br />
10<br />
4,9<br />
100,0<br />
95,1<br />
16<br />
6,3<br />
100,0<br />
93,7<br />
133,00 kg/km<br />
72 mm<br />
-20°C<br />
+60°C<br />
1,5 MJ/m<br />
82,00 kg/km<br />
62,5<br />
12,7<br />
95,0<br />
82,3<br />
100<br />
16,3<br />
93,0<br />
76,7<br />
200<br />
23,5<br />
90,0<br />
66,5<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category8,<br />
Flame-retardant acc. to IEC60332-3, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
300<br />
29,4<br />
87,0<br />
57,6<br />
600<br />
42,8<br />
81,0<br />
38,2<br />
S-STP duplex<br />
Application<br />
HELUKAT ® 1200 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as Gigabit E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet,<br />
E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
800647, S-STP 2x(4x2xAWG 22/1) FRNC<br />
78<br />
1000<br />
53,0<br />
78,0<br />
25,0<br />
1200<br />
59,0<br />
77,0<br />
18,0
Multimedia Cable 1500<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(db/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 4x2xAWG 22/1 FRNC<br />
0,64 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
-<br />
FRNC<br />
approx. 8,6 mm<br />
Yellow similar to RAL 1021<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 1200 MHz<br />
120 Ohm/km max.<br />
42,00 nF/km nom.<br />
80 %<br />
10<br />
4,2<br />
110,0<br />
106,0<br />
16<br />
6,3<br />
110,0<br />
103,7<br />
80,00 kg/km<br />
68 mm<br />
-20°C<br />
+60°C<br />
0,74 MJ/m<br />
53,00 kg/km<br />
62,5<br />
12,7<br />
110,0<br />
97,3<br />
100<br />
14,4<br />
110,0<br />
95,6<br />
200<br />
21,5<br />
110,0<br />
88,5<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category8,<br />
Flame-retardant acc. to IEC60332-3, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
300<br />
27,5<br />
105,0<br />
77,5<br />
600<br />
37,7<br />
100,0<br />
62,3<br />
1000<br />
49,0<br />
92,0<br />
43,0<br />
1200<br />
54,9<br />
88,0<br />
33,1<br />
S-STP<br />
Application<br />
HELUKAT ® 1500 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as 10Gigabit E<strong>the</strong>rnet, Gigabit<br />
E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet, E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. That means applications<br />
such as multimedia (TV, Video, Data, Speach) are no problem for this series.Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
802169, S-STP 4x2xAWG 22/1 FRNC<br />
79<br />
1500<br />
62,0<br />
73,0<br />
11,0
Multimedia Cable 1500<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Core colours:<br />
Shielding 1<br />
Screen over str<strong>and</strong>ing element:<br />
Screen 1 over str<strong>and</strong>ing:<br />
Screen 2 over str<strong>and</strong>ing:<br />
Outer sheath material:<br />
Cable dimensions:<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Loop resistance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
ACR<br />
Technical <strong>data</strong><br />
(MHz)<br />
(db/100m)<br />
(db)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
S-STP 2x(4x2xAWG 22/1) FRNC<br />
0,64 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
wh/bu, wh/og, wh/gn, wh/bn<br />
-<br />
Polyester foil, aluminium-lined<br />
Cu braid<br />
-<br />
FRNC<br />
approx. 8,6 mm x 18,2 mm<br />
Yellow similar to RAL 1021<br />
100 Ohm ± 15 ohm at 1 to 100 MHz<br />
100 Ohm ± 20 ohm at 101 to 1200 MHz<br />
120 Ohm/km max.<br />
42,00 nF/km nom.<br />
80 %<br />
10<br />
4,2<br />
110,0<br />
106,0<br />
16<br />
6,3<br />
110,0<br />
103,7<br />
160,00 kg/km<br />
68 mm<br />
-20°C<br />
+60°C<br />
1,5 MJ/m<br />
106,00 kg/km<br />
62,5<br />
12,7<br />
110,0<br />
97,3<br />
100<br />
14,4<br />
110,0<br />
95,6<br />
200<br />
21,5<br />
110,0<br />
88,5<br />
Norms<br />
Acc. to ISO/IEC11801, Acc. to EN50173, Acc. to EIA/TIA568-A, Category8,<br />
Flame-retardant acc. to IEC60332-3, Smoke density acc. to IEC61034, Halogen-free acc.<br />
to 60754-2, Corrosiveness acc. to EN50267-2-3<br />
<br />
300<br />
27,5<br />
105,0<br />
77,5<br />
600<br />
37,7<br />
100,0<br />
62,3<br />
1000<br />
49,0<br />
92,0<br />
43,0<br />
S-STP duplex<br />
Application<br />
HELUKAT ® 1500 <strong>data</strong> <strong>cables</strong> are used in <strong>the</strong> tertiary, but also in <strong>the</strong> secondary level of a network. They are characterized by large<br />
performance reserves <strong>and</strong> outst<strong>and</strong>ing performance. They can be used to implement services such as 10Gigabit E<strong>the</strong>rnet, Gigabit<br />
E<strong>the</strong>rnet, Fast E<strong>the</strong>rnet, E<strong>the</strong>rnet, ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. That means applications<br />
such as multimedia (TV, Video, Data, Speach) are no problem for this series.Likewise, <strong>the</strong> mechanical characteristics are perfectly<br />
suited for <strong>the</strong> application in tight cable channels <strong>and</strong> platforms due to <strong>the</strong>ir optimized construction.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
802170, S-STP 2x(4x2xAWG 22/1) FRNC<br />
80<br />
1200<br />
54,9<br />
88,0<br />
33,1<br />
1500<br />
62,0<br />
73,0<br />
11,0
LAN Cable TWINAX<br />
Cable structure<br />
Inner conductor diameter:<br />
Core insulation:<br />
Core colours:<br />
Screen over str<strong>and</strong>ing element:<br />
Screen over str<strong>and</strong>ing 1:<br />
Screen over str<strong>and</strong>ing 2:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Mutual capacitance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Copper weight:<br />
Twinax indoor or outdoor<br />
1 x AWG 20, Copper, bare + 1 x AWG 20,<br />
Copper, tinned<br />
PE<br />
Transparent<br />
Solid PE dielectric<br />
-<br />
Cu braid, tinned<br />
PVC / PE<br />
approx. 8,3 mm / approx. 9,3 mm<br />
Black<br />
105 Ohm<br />
53 nF/km nom.<br />
66 %<br />
100<br />
14,0<br />
88,00 kg/km<br />
125 mm<br />
-10°C<br />
+80°C<br />
51 kg/km<br />
IBM P/N 7 362 211<br />
Application<br />
HELUKABEL ® TWINAX <strong>cables</strong> are used in <strong>the</strong> area of <strong>the</strong> IBM computer systems S/36, S/38 <strong>and</strong> AS400. By using a special PE sheath,<br />
an outdoor version was developed as well.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
80072, IBM P/N 7362211 Twinax indoor<br />
81<br />
80073, IBM P/N 7362211 Twinax outdoor
LAN Cable IVS<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Number of cores:<br />
Core colours:<br />
Screen over str<strong>and</strong>ing element:<br />
Screen over str<strong>and</strong>ing 1:<br />
Screen over str<strong>and</strong>ing 2:<br />
Outer sheath material:<br />
Cable dimensions:<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Direct current resistance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Next<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
(db)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
IBM P/N 33G2772, IBM P/N 33G8224, IBM P/N 33G2775<br />
IBM P/N 33G2772<br />
type 1A<br />
0,64 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
4<br />
bk/og, rd/gn<br />
Polyester foil,<br />
aluminium-lined<br />
Cu braid, tinned<br />
-<br />
PVC<br />
approx. 7,6 mm x 11,9 mm<br />
Black<br />
150 Ohm<br />
± 15 ohm at 3 to 20 MHz<br />
185 Ohm<br />
± 18.5 ohm at 38.4 kHz<br />
270 Ohm<br />
± 27 ohm at 9.6 kHz<br />
57,1 Ohm/km<br />
78 %<br />
20<br />
7,4<br />
80,0<br />
85,00 kg/km<br />
110 mm<br />
-10°C<br />
+70°C<br />
1,7 MJ/m<br />
38,0 kg/km<br />
100<br />
18,7<br />
60,0<br />
IBM P/N 33G8224<br />
type 1A mini<br />
0,4 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
4<br />
bk/og, rd/gn<br />
Polyester foil,<br />
aluminium-lined<br />
Cu braid, tinned<br />
-<br />
PVC<br />
approx. 5,5 mm x 8,9 mm<br />
Black<br />
150 Ohm<br />
± 15 ohm at 3 to 20 MHz<br />
235 Ohm<br />
± 23.5 ohm at 38.4 kHz<br />
390 Ohm<br />
± 39 ohm at 9.6 kHz<br />
151 Ohm/km<br />
78 %<br />
20<br />
4,9<br />
50,0<br />
60,00 kg/km<br />
84 mm<br />
-10°C<br />
+70°C<br />
0,68 MJ/m<br />
21,0 kg/km<br />
100<br />
12,3<br />
39,0<br />
IBM P/N 33G2775<br />
type 6A<br />
0,48 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
4<br />
bk/og, rd/gn<br />
Polyester foil,<br />
aluminium-lined<br />
Cu braid, tinned<br />
-<br />
PVC<br />
approx. 7,8 mm<br />
Black<br />
150 Ohm<br />
± 15 ohm at 3 to 20 MHz<br />
235 Ohm<br />
± 35.25 ohm at 38.4 kHz<br />
390 Ohm<br />
± 58.5 ohm at 9.6 kHz<br />
151 Ohm/km<br />
-<br />
20<br />
7,4<br />
60,0<br />
70,00 kg/km<br />
117 mm<br />
-10°C<br />
+70°C<br />
0,78 MJ/m<br />
25,0 kg/km<br />
Application<br />
HELUKABEL ® IVS types are used in <strong>the</strong> area of <strong>the</strong> IVS system, developed by IBM. They correspond to <strong>the</strong> wiring guidelines set by<br />
IBM.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
80068, IBM P/N 33G2772<br />
type 1A<br />
82<br />
80070, IBM P/N 33G8224<br />
type 1A mini<br />
100<br />
18,7<br />
49,0<br />
80071, IBM P/N 33G2775<br />
type 6A
LAN Cable<br />
Cable structure<br />
Inner conductor diameter:<br />
Conductor material:<br />
Core insulation:<br />
Number of cores:<br />
Core colours:<br />
Screen over str<strong>and</strong>ing element:<br />
Screen over str<strong>and</strong>ing 1:<br />
Screen over str<strong>and</strong>ing 2:<br />
Outer sheath material:<br />
Outer Ø<br />
Outer sheath colour:<br />
Electrical <strong>data</strong><br />
Characteristic impedance:<br />
Mutual capacitance:<br />
Direct current resistance:<br />
Rel. propagation velocity:<br />
Typical values<br />
Frequency<br />
Attenuation<br />
Technical <strong>data</strong><br />
(MHz)<br />
(dB/100m)<br />
Weight:<br />
Min. bending radius for laying:<br />
Operating temperature range min.:<br />
Operating temperature range max.:<br />
Caloric load, approx. value:<br />
Copper weight:<br />
E<strong>the</strong>rnet Cheapernet Cable, Yellow Cable, Transceiver<br />
Cable<br />
Cheapernet Cable<br />
0,72 mm<br />
Copper, tinned<br />
Foam-skin-PE<br />
1<br />
White<br />
-<br />
Polyester foil,<br />
aluminium-lined<br />
Cu braid, tinned<br />
PVC<br />
approx. 4,6 mm<br />
Grey<br />
50 Ohm<br />
88,59 nF/km nom.<br />
50 Ohm/km<br />
77 %<br />
4<br />
1,2<br />
32,00 kg/km<br />
69 mm<br />
-10°C<br />
+80°C<br />
0,36 MJ/m<br />
21,0 kg/km<br />
10<br />
1,8<br />
Yellow Cable<br />
2,17 mm<br />
Copper, bare<br />
Foam-skin-PE<br />
1<br />
Transparent<br />
Polyester foil,<br />
aluminium-lined<br />
Cu braid, tinned<br />
Polyester foil,<br />
aluminium-lined<br />
PVC<br />
approx. 10,3 mm<br />
Yellow<br />
50 Ohm<br />
78 nF/km nom.<br />
-<br />
85 %<br />
4<br />
3,3<br />
176 kg/km<br />
117 mm<br />
-10°C<br />
+70°C<br />
-<br />
128,0 kg/km<br />
10<br />
4,6<br />
Transceiver Cable<br />
0,89 mm<br />
Copper, tinned<br />
PE<br />
8<br />
gn/bu, ye/og, gy/wh, rd/bk<br />
Polyester foil,<br />
aluminium-lined<br />
-<br />
Polyester foil,<br />
aluminium-lined<br />
PVC<br />
approx. 10,6 mm<br />
Grey<br />
78 Ohm<br />
64 nF/km nom.<br />
-<br />
66 %<br />
4<br />
4,2<br />
10<br />
6,0<br />
142,00 kg/km<br />
159 mm<br />
-10°C<br />
+60°C<br />
-<br />
95,0 kg/km<br />
Application<br />
HELUKABEL ® ETHERNET types are used as baselines (Yellow + Cheapernet) <strong>and</strong> cable connections (Transceiver or AUI) <strong>with</strong>in <strong>the</strong><br />
E<strong>the</strong>rnet wiring structure.<br />
Part no.<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
80044, Cheapernet cable<br />
83<br />
80074, Yellow cable<br />
80076, Transceiver cable
HF-Radiating Cables<br />
HF HDPE<br />
Cable structure<br />
The coax structure is identical for all sizes: inner conductor, foamed dielectric, outer conductor, outer jacket black. This assures <strong>the</strong><br />
same connector plugs <strong>and</strong> clamps can always be used. The only difference between <strong>the</strong> various variants is <strong>the</strong> form of <strong>the</strong> opening<br />
of <strong>the</strong> outer conductor. These forms determine <strong>the</strong> relationship between <strong>the</strong> inner <strong>and</strong> outer conductors. Electrical characteristics,<br />
such as attenuation, coupling loss, reflection factor as well as environmental conditions (such as dust, salt, moisture, etc.) are<br />
influenced in this way. The optimum cable can <strong>the</strong>n be determined from <strong>the</strong> knowledge of <strong>the</strong>se parameters <strong>and</strong> <strong>the</strong> application<br />
<strong>data</strong> (reach, frequency range, etc.) The technical differences can be seen from <strong>the</strong> <strong>data</strong> for <strong>the</strong> system loss <strong>and</strong> <strong>the</strong> 120 dB length.<br />
The outer jacket is made of black polyethylene.<br />
Designation<br />
Nominal<br />
size<br />
Outer Ø<br />
ca. mm<br />
Weight<br />
kg / km<br />
Corrugations, groups of apertures at large intervals<br />
HALFU 12-50 1/2" 15,0 290,0<br />
HRLF 58-50 5/8" 22,0 380,0<br />
HRLF 78-50 7/8" 28,7 620,0<br />
HRLFW 78-50 7/8" 28,7 620,0<br />
HRLF 114-50 1 1/4" 38,8 920,0<br />
HRLFW 114-50 1 1/4" 38,8 920,0<br />
HRLFW 158-50<br />
<br />
1 5/8" 48,0 1200,0<br />
Corrugations, groups of vertical slots at short intervals<br />
HRLKW 12-50 1/2" 15,0 290,0<br />
HRLKU 12-50 1/2" 15,0 290,0<br />
HRLKW 58-50 5/8" 22,0 380,0<br />
HRLKU 58-50 5/8" 22,0 380,0<br />
HRLKW 78-50 7/8" 28,7 620,0<br />
HRLKU 78-50 7/8" 28,7 620,0<br />
HRLKW 114-50 1 1/4" 38,8 920,0<br />
HRLKU 114-50 1 1/4" 38,8 920,0<br />
HRLKU 158-50<br />
<br />
1 5/8" 48,0 1200,0<br />
Corrugations, groups of vertical slots at variable intervals<br />
HRLV 114-50 1 1/4" 38,8 920,0<br />
HRLVW 114-50 1 1/4" 38,8 920,0<br />
HRLVU 158-50<br />
<br />
1 5/8" 48,0 1200,0<br />
Corrugations, groups of apertures, sloping slots<br />
HRAY 58-50 5/8" 22,0 400,0<br />
HRAY 78-50 7/8" 28,7 640,0<br />
HRAY 114-50 1 1/4" 38,8 980,0<br />
HRAY 158-50<br />
<br />
1 5/8" 48,0 1200,0<br />
Corrugations, groups of milled slots<br />
HRCF 38-50 3/8" 12,0 130,0<br />
HRCF 12-50 1/2" 16,0 230,0<br />
HRCF 78-50 7/8" 28,0 570,0<br />
HRCF 114-50 1 1/4" 40,0 950,0<br />
HRCF 158-50 1 5/8" 51,0 1350,0<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
450<br />
129<br />
113<br />
93<br />
100<br />
86<br />
90<br />
92<br />
124<br />
126<br />
107<br />
110<br />
95<br />
101<br />
90<br />
96<br />
101<br />
96<br />
84<br />
99<br />
103<br />
95<br />
87<br />
108<br />
159<br />
124<br />
105<br />
102<br />
100<br />
1 km system loss (dB)<br />
<br />
900 1800<br />
(MHz)<br />
2200<br />
155<br />
133<br />
110<br />
114<br />
103<br />
100<br />
97<br />
154<br />
160<br />
127<br />
125<br />
115<br />
113<br />
103<br />
101<br />
95<br />
89<br />
86<br />
82<br />
134<br />
129<br />
103<br />
106<br />
196<br />
151<br />
122<br />
113<br />
109<br />
195<br />
-<br />
-<br />
150<br />
-<br />
144<br />
120<br />
274<br />
289<br />
168<br />
177<br />
262<br />
166<br />
163<br />
125<br />
113<br />
-<br />
122<br />
95<br />
-<br />
-<br />
-<br />
120<br />
259<br />
202<br />
155<br />
134<br />
122<br />
210<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
324<br />
-<br />
197<br />
-<br />
190<br />
-<br />
145<br />
123<br />
-<br />
-<br />
97<br />
-<br />
-<br />
-<br />
132<br />
-<br />
225<br />
166<br />
148<br />
137<br />
2400<br />
<br />
216 <br />
- <br />
- <br />
- <br />
- <br />
- <br />
- <br />
- <br />
349 <br />
- <br />
208 <br />
- <br />
212 <br />
- <br />
156 <br />
133 <br />
- <br />
- <br />
102 <br />
- <br />
- <br />
- <br />
157 <br />
- <br />
238 <br />
169 <br />
153 <br />
143 <br />
450<br />
830<br />
1300<br />
1965<br />
1750<br />
2580<br />
2500<br />
2650<br />
930<br />
900<br />
1340<br />
1265<br />
1780<br />
1650<br />
2300<br />
2115<br />
2150<br />
-<br />
-<br />
-<br />
1440<br />
1760<br />
2570<br />
1670<br />
540<br />
930<br />
1460<br />
1715<br />
2030<br />
120 dB-length (m)<br />
<br />
900 1800<br />
(MHz)<br />
2200<br />
560<br />
900<br />
1220<br />
1150<br />
1450<br />
1630<br />
1850<br />
625<br />
600<br />
930<br />
915<br />
1090<br />
1135<br />
1440<br />
1550<br />
1900<br />
-<br />
-<br />
-<br />
810<br />
870<br />
1380<br />
1500<br />
395<br />
630<br />
960<br />
1180<br />
1365<br />
350<br />
-<br />
-<br />
650<br />
-<br />
710<br />
1000<br />
300<br />
270<br />
570<br />
490<br />
320<br />
560<br />
610<br />
925<br />
1150<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
1000<br />
250<br />
390<br />
600<br />
775<br />
960<br />
310<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
235<br />
-<br />
425<br />
-<br />
460<br />
-<br />
695<br />
950<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
815<br />
-<br />
290<br />
530<br />
605<br />
680<br />
2400<br />
Part no.<br />
295 800171<br />
- 800172<br />
- 800173<br />
- 800174<br />
- 800175<br />
- 800176<br />
- 800177<br />
- 800178<br />
220 800179<br />
- 800180<br />
400 800181<br />
- 800182<br />
395 800183<br />
- 800184<br />
615 800185<br />
820 800186<br />
- 800187<br />
- 800188<br />
- 800189<br />
- 800190<br />
- 800191<br />
- 800192<br />
600 800193<br />
- 800194<br />
240 800195<br />
515 800196<br />
555 800197<br />
605 800198<br />
Application<br />
Radiating coax <strong>cables</strong> permit communication in areas where electromagnetic propagation is impeded, undesirable, or impossible.<br />
This may be <strong>the</strong> case in tunnels, mines, buildings along railway routes <strong>and</strong> lines, as well as in large building complexes, such as<br />
exhibition centres <strong>and</strong> airports.<br />
84
HF-Radiating Cables<br />
HF FRNC<br />
Cable structure<br />
The coax structure is identical for all sizes: inner conductor, foamed dielectric, outer conductor, outer jacket black. This assures <strong>the</strong><br />
same connector plugs <strong>and</strong> clamps can always be used. The only difference between <strong>the</strong> various variants is <strong>the</strong> form of <strong>the</strong> opening<br />
of <strong>the</strong> outer conductor. These forms determine <strong>the</strong> relationship between <strong>the</strong> inner <strong>and</strong> outer conductors. Electrical characteristics,<br />
such as attenuation, coupling loss, reflection factor as well as environmental conditions (such as dust, salt, moisture, etc.) are<br />
influenced in this way. The optimum cable can <strong>the</strong>n be determined from <strong>the</strong> knowledge of <strong>the</strong>se parameters <strong>and</strong> <strong>the</strong> application<br />
<strong>data</strong> (reach, frequency range etc.). The technical differences can be seen from <strong>the</strong> <strong>data</strong> for <strong>the</strong> system loss <strong>and</strong> <strong>the</strong> 120 dB length.<br />
The outer sheath material is made of a black halogen-free <strong>and</strong> flame-resistant compound.<br />
Designation<br />
Nominal<br />
size<br />
Outer Ø<br />
ca. mm<br />
Weight<br />
kg / km<br />
Corrugations, groups of apertures at large intervals<br />
HALFU 12-50 1/2" 15,0 290,0<br />
HRLF 58-50 5/8" 22,0 380,0<br />
HRLF 78-50 7/8" 28,7 620,0<br />
HRLFW 78-50 7/8" 28,7 620,0<br />
HRLF 114-50 1 1/4" 38,8 920,0<br />
HRLFW 114-50 1 1/4" 38,8 920,0<br />
HRLFW 158-50<br />
<br />
1 5/8" 48,0 1200,0<br />
Corrugations, groups of vertical slots at short intervals<br />
HRLKW 12-50 1/2" 15,0 290,0<br />
HRLKU 12-50 1/2" 15,0 290,0<br />
HRLKW 58-50 5/8" 22,0 380,0<br />
HRLKU 58-50 5/8" 22,0 380,0<br />
HRLKW 78-50 7/8" 28,7 620,0<br />
HRLKU 78-50 7/8" 28,7 620,0<br />
HRLKW 114-50 1 1/4" 38,8 920,0<br />
HRLKU 114-50 1 1/4" 38,8 920,0<br />
HRLKU 158-50<br />
<br />
1 5/8" 48,0 1200,0<br />
Corrugations, groups of vertical slots at variable intervals<br />
HRLV 114-50 1 1/4" 38,8 920,0<br />
HRLVW 114-50 1 1/4" 38,8 920,0<br />
HRLVU 158-50<br />
<br />
1 5/8" 48,0 1200,0<br />
Corrugations, groups of apertures, sloping slots<br />
HRAY 58-50 5/8" 22,0 400,0<br />
HRAY 78-50 7/8" 28,7 640,0<br />
HRAY 114-50 1 1/4" 38,8 980,0<br />
HRAY 158-50<br />
<br />
1 5/8" 48,0 1200,0<br />
Corrugations, groups of milled slots<br />
HRCF 38-50 3/8" 12,0 130,0<br />
HRCF 12-50 1/2" 16,0 230,0<br />
HRCF 78-50 7/8" 28,0 570,0<br />
HRCF 114-50 1 1/4" 40,0 950,0<br />
HRCF 158-50 1 5/8" 51,0 1350,0<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
450<br />
129<br />
113<br />
93<br />
100<br />
86<br />
90<br />
92<br />
124<br />
126<br />
107<br />
110<br />
95<br />
101<br />
90<br />
96<br />
101<br />
96<br />
84<br />
99<br />
103<br />
95<br />
87<br />
108<br />
159<br />
124<br />
105<br />
102<br />
100<br />
1 km system loss (dB)<br />
<br />
900 1800<br />
(MHz)<br />
2200<br />
155<br />
133<br />
110<br />
114<br />
103<br />
100<br />
97<br />
154<br />
160<br />
127<br />
125<br />
115<br />
113<br />
103<br />
101<br />
95<br />
89<br />
86<br />
82<br />
134<br />
129<br />
103<br />
106<br />
196<br />
151<br />
122<br />
113<br />
109<br />
195<br />
-<br />
-<br />
150<br />
-<br />
144<br />
120<br />
274<br />
289<br />
168<br />
177<br />
262<br />
166<br />
163<br />
125<br />
113<br />
-<br />
122<br />
95<br />
-<br />
-<br />
-<br />
120<br />
259<br />
202<br />
155<br />
134<br />
122<br />
210<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
324<br />
-<br />
197<br />
-<br />
190<br />
-<br />
145<br />
123<br />
-<br />
-<br />
97<br />
-<br />
-<br />
-<br />
132<br />
-<br />
225<br />
166<br />
148<br />
137<br />
2400<br />
<br />
216 <br />
- <br />
- <br />
- <br />
- <br />
- <br />
- <br />
- <br />
349 <br />
- <br />
208 <br />
- <br />
212 <br />
- <br />
156 <br />
133 <br />
- <br />
- <br />
102 <br />
- <br />
- <br />
- <br />
157 <br />
- <br />
238 <br />
169 <br />
153 <br />
143 <br />
450<br />
830<br />
1300<br />
1965<br />
1750<br />
2580<br />
2500<br />
2650<br />
930<br />
900<br />
1340<br />
1265<br />
1780<br />
1650<br />
2300<br />
2115<br />
2150<br />
-<br />
-<br />
-<br />
1440<br />
1760<br />
2570<br />
1670<br />
540<br />
930<br />
1460<br />
1715<br />
2030<br />
120 dB-length (m)<br />
<br />
900 1800<br />
(MHz)<br />
2200<br />
560<br />
900<br />
1220<br />
1150<br />
1450<br />
1630<br />
1850<br />
625<br />
600<br />
930<br />
915<br />
1090<br />
1135<br />
1440<br />
1550<br />
1900<br />
-<br />
-<br />
-<br />
810<br />
870<br />
1380<br />
1500<br />
395<br />
630<br />
960<br />
1180<br />
1365<br />
350<br />
-<br />
-<br />
650<br />
-<br />
710<br />
1000<br />
300<br />
270<br />
570<br />
490<br />
320<br />
560<br />
610<br />
925<br />
1150<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
1000<br />
250<br />
390<br />
600<br />
775<br />
960<br />
310<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
235<br />
-<br />
425<br />
-<br />
460<br />
-<br />
695<br />
950<br />
-<br />
-<br />
-<br />
-<br />
-<br />
-<br />
815<br />
-<br />
290<br />
530<br />
605<br />
680<br />
2400<br />
Part no.<br />
295 800227<br />
- 800228<br />
- 800229<br />
- 800230<br />
- 800231<br />
- 800232<br />
- 800233<br />
- 800234<br />
220 800235<br />
- 800236<br />
440 800237<br />
- 800238<br />
395 800239<br />
- 800240<br />
615 800241<br />
820 800242<br />
- 800243<br />
- 800244<br />
- 800245<br />
- 800246<br />
- 800247<br />
- 800248<br />
600 800249<br />
- 800250<br />
240 800251<br />
515 800252<br />
555 800253<br />
605 800254<br />
Application<br />
Radiating coax <strong>cables</strong> permit communication in areas where electromagnetic propagation is impeded, undesirable, or impossible.<br />
This may be <strong>the</strong> case in tunnels, mines, buildings along railway routes <strong>and</strong> lines, as well as in large building complexes, such as<br />
exhibition centres <strong>and</strong> airports.<br />
85
HF-Cables flexible<br />
HF FLEX<br />
Cable structure<br />
Flexible ultrahigh-frequency <strong>cables</strong> have a coax cable structure, where <strong>the</strong> inner <strong>and</strong> outer conductors are kept apart by a dielectric.<br />
This dielectric is applied by a special manufacturing process. The outer conductors have an annular corrugation. The corrugation<br />
troughs press into <strong>the</strong> dielectric, <strong>the</strong>reby sealing this cavities. This prevents any penetrated water from advancing through<br />
annular-corrugated <strong>cables</strong>. The jacket for <strong>the</strong>se <strong>cables</strong> is made of black abrasion-resistant PE. This material is halogen-free <strong>and</strong><br />
UV-resistant. As an optional, a flame-resistant version is available.<br />
Designation<br />
Nominal<br />
size<br />
Cellflex, low loss<br />
HCF 14-50<br />
1/4"<br />
HLCF 38-50<br />
3/8"<br />
HLCF 12-50<br />
1/2"<br />
HLCF 58-50<br />
5/8"<br />
HLCF 78-50<br />
7/8"<br />
HLCF 114-50 1 1/4"<br />
HLCFS 114-50 1 1/4"<br />
HLCF 158-50 1 5/8"<br />
HLCF 214-50<br />
<br />
Cellflex, superflexible<br />
2 1/4"<br />
HSCF 14-50<br />
1/4"<br />
HSCF 38-50<br />
3/8"<br />
HSCF 12-50<br />
<br />
Cellflex, ultraflexible<br />
1/2"<br />
HUCF 12-50<br />
1/2"<br />
Outer conductor<br />
form<br />
Corrugations<br />
Corrugations<br />
Corrugations<br />
Corrugations<br />
Corrugations<br />
Corrugations<br />
Corrugations<br />
Corrugations<br />
Corrugations<br />
Corrugations<br />
Corrugations<br />
Corrugations<br />
Corrugations<br />
Dimensions <strong>and</strong> specifications may be changed <strong>with</strong>out prior notice.<br />
Outer Ø<br />
ca. mm<br />
10,0<br />
11,2<br />
16,2<br />
21,4<br />
28,0<br />
39,4<br />
39,4<br />
51,0<br />
60,0<br />
7,8<br />
10,2<br />
13,7<br />
13,7<br />
Min. bending<br />
radius for laying<br />
mm<br />
40<br />
50<br />
70<br />
90<br />
120<br />
200<br />
200<br />
300<br />
410<br />
25<br />
25<br />
32<br />
30<br />
Attenuation<br />
at 100m<br />
dB<br />
14,50<br />
10,30<br />
7,20<br />
5,60<br />
4,10<br />
3,40<br />
2,90<br />
2,50<br />
2,20<br />
19,50<br />
14,10<br />
11,20<br />
13,20<br />
Medium power<br />
kW<br />
0,600<br />
0,600<br />
1,200<br />
1,700<br />
2,500<br />
2,400<br />
3,600<br />
4,200<br />
5,400<br />
0,300<br />
0,600<br />
0,800<br />
0,700<br />
Weight<br />
kg / km<br />
130,0<br />
120,0<br />
220,0<br />
370,0<br />
550,0<br />
1050,0<br />
1150,0<br />
1530,0<br />
1920,0<br />
70,0<br />
120,0<br />
210,0<br />
240,0<br />
Part no.<br />
800201<br />
800202<br />
800203<br />
800204<br />
800205<br />
800206<br />
800207<br />
800208<br />
800209<br />
800210<br />
800211<br />
800212<br />
800213<br />
Application<br />
Flexible ultrahigh-frequency <strong>cables</strong> are used as <strong>the</strong> <strong>cables</strong> for <strong>the</strong> antennae in directional radio, radio stations, satellite radio, radio<br />
<strong>and</strong> TV transmitters, etc. The most important parameters for <strong>the</strong>se coax <strong>cables</strong> are characteristic impedance, reflection factor,<br />
attenuation, average power <strong>and</strong> <strong>the</strong> bending radius.<br />
86
Testingcenter<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
87