ECC Flows<br />
λ No ECC flow into the intact loop,<br />
since<br />
– intact loop pressure > broken loop pressure<br />
(intact loop was isolated from the broken<br />
loop)<br />
– Intact loop pressure > ECC supply pressure<br />
λ LOCA signal & loop isolation<br />
initiated at 9 s after accident<br />
λ Loop isolation complete by 29 s<br />
λ ECC flows into the broken loop, 3<br />
stages<br />
– High-pressure High pressure injection initiation (38 s)<br />
– Medium-pressure Medium pressure injection (293 s)<br />
– Low-pressure Low pressure injection (678 s)<br />
24-May-01 <strong>CANDU</strong> <strong>Safety</strong> - <strong>#12</strong> - <strong>Large</strong> LOCA.ppt Rev. 0 12