Series 6 I/O 9/8 module
Series 6 I/O 9/8 module
Series 6 I/O 9/8 module
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Series</strong> 6<br />
I/O 9/8<br />
<strong>module</strong><br />
I/O 9/8MD HS<br />
The I/O 9/8 <strong>module</strong> is a<br />
component used for controlling<br />
elevators, turnstiles and<br />
revolving door stops etc. in<br />
more complex access control<br />
environments.<br />
Its current status is relayed<br />
by the nine digital inputs<br />
and eight relays – each with<br />
a change-over contact – to<br />
the superordinate control<br />
unit (ACT e.g. B6L, M6L,<br />
TC16) which evaluates this<br />
and then controls the electrical<br />
function units.<br />
An I/O 9/8 <strong>module</strong> can also<br />
bundle the signals of several<br />
doors e.g. door opening push<br />
buttons or door open messages<br />
and transmit the control<br />
signals for door opening<br />
to the doors. This considerably<br />
reduces the number<br />
of separate door <strong>module</strong>s<br />
and the amount of wiring required.<br />
An I/O 9/8 <strong>module</strong> can<br />
also be used for doors that<br />
need to be controlled in remote<br />
premises. Up to eight<br />
doors can be opened using<br />
straightforward access control,<br />
and three to four doors<br />
in the case of more complex<br />
monitoring requirements<br />
such as door status messages,<br />
internal push button and<br />
local alarm. Communication<br />
between the I/O 9/8 <strong>module</strong><br />
and the control centre is via<br />
RS485 and the DP1 protocol<br />
and can bridge a distance of<br />
up to 6,000 metres.<br />
The I/O 9/8 <strong>module</strong> is available<br />
in two styles: the wall<br />
version can be surfacemounted<br />
on the wall or, for<br />
example, inconspicuously in<br />
a false ceiling. The I/O 9/8<br />
top-hat <strong>module</strong> is designed<br />
for snap mounting on standardised<br />
top-hat rails and can<br />
thus be conveniently integrated<br />
into switchgear assemblies.<br />
I/O 9/8MD WM
WN 05361951532, E, 3, BD, 12/2009<br />
Technical data I/O 9/8 <strong>module</strong><br />
Input voltage 16 V to 36 VDC (SELV)<br />
16 V to 24 VAC (SELV)<br />
Wall mounting: optional: 230 V power supply<br />
unit can be retrofitted<br />
Consumption Device: max. 5 W, e.g. 200 mA at 24 V<br />
Interfaces RS485<br />
Protocols DP1<br />
Anti-tamper<br />
monitoring<br />
Available<br />
Outputs 8 relays: maximum load 60 W<br />
45 VDC/2 A (SELV)<br />
30 VAC/2 A (SELV)<br />
Inputs<br />
(digital)<br />
Cable<br />
(recommended)<br />
9 opto-couplers, plus-switching:<br />
load 24 VDC (max. 36 VDC, 24 VAC/10 mA)<br />
Switching thresholds:<br />
active at 10 VDC or 9 VAC<br />
passive at 4 VDC or 4 VAC<br />
RS485 data cable:<br />
J-2Y(ST)Y 2 x 2 x 0.6 mm 2 ST III BD<br />
Relay cable:<br />
J-2Y(ST)Y 2 x 2 x 0.6 mm 2 ST III BD<br />
Digital input cable:<br />
J-2Y(ST)Y 2 x 2 x 0.6 mm 2 ST III BD<br />
Power supply cable:<br />
J-2Y(ST)Y 2 x 2 x 0.6 mm 2 ST III BD<br />
Line length RS485: max. 6,000 m<br />
Relay: max. 200 m<br />
Digital inputs: max. 100 m<br />
Power supply: max. 200 m complying with<br />
the permissible input voltage limits<br />
Ambient<br />
conditions<br />
General<br />
design<br />
Protection<br />
rating<br />
Resistance to<br />
interference<br />
Emission<br />
standard<br />
Operating temperature range:<br />
-20°C to +50°C<br />
Storage temperature range:<br />
-20°C to +70°C<br />
Humidity range:<br />
0 to 80%, non-condensing<br />
Wall mounting:<br />
EN 60 950, protection class III (at 230<br />
VAC operation protection class I)<br />
Top-hat rail mounting:<br />
EN 60 950, protection class III<br />
Mounting on rails in accordance with:<br />
EN 60715<br />
TH35-7.5 top-hat rails for installation in<br />
switchgear assemblies complying with<br />
EN 60439-1<br />
IP 30<br />
EN 61000-6-2<br />
Immunity for industrial environments<br />
EN 61000-6-3<br />
Emission standard for residential environments<br />
Dimensions Wall mounting:<br />
(W x H x D) 145.5 x 243.5 x 61 mm<br />
Top-hat rail mounting:<br />
(W x H x D) 198 x 75 x 71 mm<br />
corresponds to a device width of 11 horizontal<br />
pitch<br />
Casing colour Wall mounting: RAL 7016 (anthracite grey)<br />
Top-hat rail mounting: anodised aluminium<br />
Weight Wall mounting:<br />
1,500 g without 230 V PSU<br />
2,100 g with 230 V PSU<br />
Top-hat rail mounting: 600 g<br />
Subject to technical alterations<br />
DORMA STA<br />
(Security, Time + Access)<br />
DORMA<br />
Time + Access GmbH<br />
Mainzer Straße 36-52<br />
D-53179 Bonn<br />
Tel. +49 228 8554-0<br />
Fax +49 228 8554-175<br />
www.dorma-time-access.com<br />
DORMA GmbH Co. KG<br />
DORMA Platz 1<br />
D-58256 Ennepetal<br />
Tel. +49 2333 793-0<br />
Fax +49 2333 793-495<br />
www.dorma.com