Conclusions<br />
• SiSi a free <strong>SiPM</strong> Simulator<br />
– write me: nepomuk@scipp.ucsc.edu<br />
• crosstalk measurements can be used to characterize photon<br />
emission dur<strong>in</strong>g avalanches<br />
• only photons with<strong>in</strong> a narrow energy <strong>in</strong>terval (1.1eV-1.4eV) cause<br />
optical crosstalk; reason: strong energy dependence <strong>of</strong> absorption<br />
lengths<br />
• measured <strong>in</strong>tensity <strong>of</strong> photons between 1.1eV-1.40eV : ~3•10 -5<br />
photons / avalanche electron-hole pair; estimated uncerta<strong>in</strong>ty: 2<br />
Nepomuk Otte 13