13 <strong>VICTRIX</strong> <strong>Superior</strong> 32 <strong>kW</strong> TECHNICAL DATA<br />

<strong>VICTRIX</strong> <strong>Superior</strong> <strong>kW</strong> <strong>Export</strong><br />

<strong>VICTRIX</strong> <strong>Superior</strong> <strong>kW</strong> X <strong>Export</strong><br />

Maximum nominal heat input <strong>kW</strong> (kcal/h) 32.7 (28,082)<br />

Maximum useful/nominal heat output <strong>kW</strong> (kcal/h) 32.0 (27,520)<br />

Minimum nominal heat input <strong>kW</strong> (kcal/h) 6.6 (5,634)<br />

Minimum useful/nominal heat output <strong>kW</strong> (kcal/h) 6.4 (5,504)<br />

Efficiency at 100% Pn (80/60°C) % 98.0<br />

Efficiency at 30% of the load (80/60°C) % 100.6<br />

Efficiency at 100% Pn (50/30°C) % 104.7<br />

Efficiency at 30% of the load (50/30°C) % 106.8<br />

Efficiency at 100% Pn (40/30°C) % 105.7<br />

Efficiency at 30% of the load (40/30°C) % 107.0<br />

Central heating system<br />

Central heating adjustable temperature (range 1 / range 2) °C 25 - 85 / 25 - 50<br />

Max. system operating temperature °C 90<br />

Max. system operating pressure bar 3<br />

System expansion vessel nominal/real capacity litres 7.5 / (6.8)<br />

System expansion vessel pre-load pressure bar 1.0<br />

Head available with flow rate of 1000 l/h kPa (m H 2 O) 26.48 (2.70)<br />

Domestic Hot Water Circuit<br />

Hot water production useful heat output <strong>kW</strong> (kcal/h) 32.0 (27,520)<br />

D.H.W. temperature adjustment °C 30 - 60<br />

D.H.W. circuit minimum dynamic pressure bar 0.3<br />

D.H.W. circuit maximum pressure bar 10<br />

D.H.W. min. flow rate litres/min 1.5<br />

Flow rate for continuous service (∆t 30°C) litres/min 16.3<br />

Gas supply<br />

Gas pressure at the METHANE burner (G20) MIN - MAX mbar 0.14 - 2.45<br />

Gas pressure at the LPG burner (G30) MIN - MAX mbar 0.15 - 2.68<br />

Gas pressure at the LPG burner (G31) MIN - MAX mbar 0.18 - 3.35<br />

Gas pressure at the METHANE burner (G20) MIN - MAX m 3 /h 0.70 - 3.46<br />

Gas pressure at the LPG burner (G30) MIN - MAX kg/h 0.52 - 2.58<br />

Gas pressure at the LPG burner (G31) MIN - MAX kg/h 0.51 - 2.54<br />

Supply voltage V/Hz 230 - 50<br />

Nominal power absorption A 0.62<br />

Installed electric power W 135<br />

Power absorbed by the fan W 26<br />

Power absorbed by the pump W 95<br />

Electrical insulation degree IP X5D<br />

Boiler water content (Aqua Celeris) litres 7.8 (4.0)<br />

Empty boiler weight kg 53.5<br />

13