03.08.2013 Views

CodeWarrior Development Studio for Power Architecture Netcomm

CodeWarrior Development Studio for Power Architecture Netcomm

CodeWarrior Development Studio for Power Architecture Netcomm

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>CodeWarrior</strong> <strong>Development</strong> <strong>Studio</strong> <strong>for</strong> <strong>Power</strong> <strong>Architecture</strong> <strong>Netcomm</strong> v10.0.1<br />

Note: In order to check whether your P4080 processor is rev1 or rev2, check the content<br />

of the e500mc's special purpose register called SVR, in the <strong>CodeWarrior</strong> register view. If<br />

the SVR register's value masked with 0xfff0fff0 is equal to 0x82000010 the processor's<br />

revision is rev1, otherwise it is rev2. For more details please consult the P4080<br />

Reference Manual.<br />

5. The trace settings are applied to the target using the active debug launch configurations.<br />

Currently the multiple active debug launch configurations associated with different P4080<br />

boards are not supported, please make sure that all active debug launch configurations are<br />

using the same P4080 board, when collecting trace data.<br />

6. U-boot in the FSL BSP (on P4080rev1) disables the aurora lanes used <strong>for</strong> Nexus trace<br />

support with the Gigabit TAP. To collect trace to Gigabit TAP probe you must enable at least<br />

2 lanes <strong>for</strong> Aurora.<br />

7. Sometimes, collecting to the NPC Buffer via the <strong>CodeWarrior</strong> Eclipse environment is not<br />

currently working. Collecting to the NPC buffer via the scripting environment (GetBufferTrace)<br />

is working.<br />

2.3.3 Per<strong>for</strong>mance Analysis Tools<br />

The "Generate a Configuration Access Log" operation, found on the Analyze Tab, requires that<br />

the "Save configuration with each captured data" options be checked on the Options Tab.<br />

The Per<strong>for</strong>mance Analysis Events viewer will be empty when initially opened. Upon completion<br />

of each collection operation it will display the collected counter data.<br />

3 System Requirements<br />

Recommended Configuration<br />

3GHz Intel® Pentium® P4 processor or better. Dual-core processor preferable.<br />

Microsoft® Windows XP<br />

2GB RAM (Step speed on machines with 1GB RAM is significantly slower)<br />

1GB free disk space<br />

Note: 500MB of free space is required on the OS drive, regardless of the free space available<br />

on the destination drive.<br />

4 Who Should Use this Release?<br />

Users developing <strong>for</strong> the P4080<br />

5 Who Should NOT Use this Release?<br />

Users developing <strong>for</strong> <strong>Power</strong>Quicc, 8xxx, 7xxx, 7xx, 6xx or 5xx based processors. These<br />

developers should use the previous (non-Eclipse based) versions of the tools.<br />

Freescale Confidential Proprietary<br />

8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!